COBAS®TaqMan® 48 Analyzer
Catalogue number 03279332001, listed by Roche Molecular Systems, Inc., United States, under Analyzer, Chemistry, Micro, For Clinical Use. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (1), Hubei (1), Henan (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
| Wuhan Landing Intelligence Medical Co., Ltd. | Wuhan | Hubei | Manufacturer | 17 |
| Autobio Labtec Instruments Co., Ltd. | Zhengzhou | Henan | Manufacturer | 3 |
Record
| Listed by | Roche Molecular Systems, Inc., United States |
|---|---|
| FDA product code | JJF |
| Device type | Analyzer, Chemistry, Micro, For Clinical Use |
| Device class | Class 1 |
| Regulation | 21 CFR 862.2170 |
| Establishment | Specification developer, Manufacturer, Exporter |
| Record published | 2014-09-17 |
| Record revised | 2025-07-14 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 03279332001 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Diamedix | Diamedix Corp. | 2 |
| Spotcheck | Astoria-Pacific, Inc. | 2 |
| Cholestech LDX™ | Alere San Diego, Inc. | 2 |
| AWS | Randox Laboratories Limited | 1 |
| Liaison® XL | Diasorin Inc. | 1 |
| Soln Wash | Randox Laboratories Limited | 1 |
| Wash conc. 1 | Randox Laboratories Limited | 1 |
| NS | Randox Laboratories Limited | 1 |
| Liaison® Easy Starter Kit | Diasorin S.P.A | 1 |
| Rabs | Randox Laboratories Limited | 1 |
| Cl Soln | Randox Laboratories Limited | 1 |
| Wash Concentrate 2 | Medtest DX | 1 |
Showing 12 of 26. All products under Analyzer, Chemistry, Micro, For Clinical Use
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K012966 | 2002-02-01 |
| K964506 | 1997-05-21 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-02-01 | Class II | Nonconforming Material/Component | Certain lots of COBAS AmpliPrep (CAP) S-tube Input (Box of 12 bags 12×24 S-tube and 12×24 S-clip) can cause the sample input tubes to stick in the barcode clips. As a consequence, the CAP instrument will lift both the sample input tube tog | 2,132 boxes | 2013-07-16 |
| 2007-05-21 | Not classified | Other | For select COBAS AMPLICOR Tests run on the COBAS AMPLICOR Analyzer in conjunction with AMPLILINK software, a discrepancy has been identified between the onboard working reagent stability information reported by AMPLILINK Software (versions | 5,806 total | 2010-02-18 |
| 2004-05-24 | Not classified | Other | Improper seating of a fiber optic cable which may cause pixel cross-talk leading to falsely elevated test results or cases of misalignment to sample-to-result mismatch. | 34 | 2006-03-08 |
| 2004-05-24 | Not classified | Other | Improper seating of a fiber optic cable which may cause pixel cross-talk leading to falsely elevated test results or cases of misalignment to sample-to-result mismatch. | 75 | 2006-03-08 |
| 2003-03-06 | Not classified | Other | A false positive result may be reported. | 16 | 2003-12-10 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.