M2000

m2000 System Pierceable Cap Sample Rack PoSt Set

Registry build 21.09.26
27manufacturers in China registered for this device type
19catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Zhejiang (6), Guangdong (4). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code JJH
Manufacturer City Province Registered as Device types
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Guangzhou Four E’s Scientific Co., Ltd. Guangzhou Guangdong Contract manufacturer 61
Nanning Tecbod Biological Technology Co., Ltd. Nanning Guangxi Contract manufacturer 51
Zhejiang Gene Science Co., Ltd. Shaoxing Zhejiang Manufacturer 31
Biomed Plastics Co. Taicang Jiangsu Contract manufacturer 29
Bioteke Corporation (Wuxi) Co., Ltd. Wuxi Jiangsu Manufacturer 21
Changsha Renji Medical Equipment Co., Ltd. Changsha Hunan Manufacturer 15
Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. Nantong Jiangsu Manufacturer 11
Phase Scientific (Shenzhen) Company Limited Shenzhen Guangdong Repacker / relabeller 8
Xian Tianlong Science AND Technology Co., Ltd. Xi’An Shaanxi Manufacturer 8

Showing 12 of 27. All 27 manufacturers in China registered for Clinical Sample Concentrator

Record

Regulatory record for m2000
Listed by Abbott Molecular, Inc., United States
FDA product code JJH
Device type Clinical Sample Concentrator
Device class Class 1
Regulation 21 CFR 862.2310
Establishment Specification developer, Manufacturer, Exporter
510(k) K092705
Record published 2016-09-01
Record revised 2023-09-29 (version 11)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, serial number
Storage Storage environment temperature up to -10 °C; Special storage condition: Protect from Light
Packaging Case of 24, case of 6, case of 4

Catalogue Numbers

Catalogue numbers for m2000
Catalogue number Size Per pack Status
01N93-01 In distribution
04J71-93 In distribution
01N97-01 In distribution
01N94-01 In distribution
01N06-01 In distribution
9K32-01 In distribution
04J72-82 In distribution
04J71-80 25 In distribution
04J71-20 500 In distribution
02N29-01 In distribution
04J71-17 96 In distribution
01N92-02 In distribution
04J71-10 96 In distribution
04J71-30 In distribution
04J71-60 In distribution
04J72-86 In distribution
9K31-01 In distribution
09K14-02 In distribution
04J71-45 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
TANBead Nucleic Acid Extraction Kit Taiwan Advanced Nanotech Inc. 124
PCRopsis Entopsis, Inc. 53
Bioer MagaBio plus Virus DNA /RNA Purification Kit III Hangzhou Bioer Technology Co., Ltd. 20
Allsheng Hangzhou Allsheng Instruments Co., Ltd. 13
TANBead Nucleic Acid Extractor Taiwan Advanced Nanotech Inc. 12
Bioer MagaBio plus Virus RNA Purification Kit II Hangzhou Bioer Technology Co., Ltd. 10
Biobase Biobase Biodustry(Shandong)Co., Ltd. 9
BioTeke Bioteke Corporation (Wuxi) Co., Ltd. 8
Prochem Vivaproducts, Inc. 8
Vivafree 500 Sartorius Stedim Lab Ltd. 6
Amicon Ultra → 4 Merck Millipore Ltd. 6
Vivafree 2 Sartorius Stedim Lab Ltd. 6

Showing 12 of 268. All products under Clinical Sample Concentrator

Recalls Naming This Product

6 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of m2000
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Abbott Molecular, Inc. 510(k) number 2014-10-23 Class II Software design (manufacturing process) Some versions of Application Specifications (App Spec) are incompatible with m2000sp system software version 6.0 and 7.0. This issue will cause Error Code 9000 (An unexpected error has occurred: Software error) to be generated when the Avai 9 CD ROMs (US); 1,273 CD ROMs (Foreign) 2016-03-08
Abbott Molecular, Inc. 510(k) number 2014-06-19 Class II Employee error Abbott Molecular identified that some of the 5 ml Reaction Vessels (RVs) contained in lots 56944001, 57026001, 57059001, and 57673001 (original vendor lot 2198077) may have an insufficient rim. An RV with an insufficient rim may not be held 1,688,000 reaction vessels 2016-02-23
Abbott Molecular, Inc. 510(k) number 2013-11-23 Class II Nonconforming Material/Component The x-drive assembly may fail prematurely. This could cause the manipulator or liquid handling arm to contact an object, shake and drip, or improperly pipet. 176 devices 2017-12-04
Abbott Molecular, Inc. 510(k) number 2012-12-04 Class II Software design An issue with the m2000sp Instrument software has been identified whereby, after a series of steps, if changes are made to the control or calibrator information on the Sample Extraction Assay Details screen, the changes are not saved. 215 units – U.S., 693 units – ROW 2016-03-08
Abbott Molecular, Inc. 510(k) number 2011-10-11 Not classified Component design/selection Abbott Molecular has received reports in which the liquid waste sensor and components in the m2000sp lower instrument cabinet overheated and/or caught fire. 432 units 2016-02-23
Abbott Molecular, Inc. 510(k) number 2011-09-08 Not classified Software design The Abbott m2000rt System software has software bug which can affect customers who manually enter a Test Order onto the m2000rt and sorts a column on the calibration or control grids of the Test Order screen by double clicking the column he 926 units 2016-03-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer