Accelerator
Accelerator APS Input / Output Module
Who Else Makes It
Concentrated in Zhejiang (2), Guangdong (2), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Zhejiang Gene Science Co., Ltd. | Shaoxing | Zhejiang | Manufacturer | 31 |
| Foshan Zike Technology Co., Ltd. | Foshan | Guangdong | Manufacturer | 9 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
| Shanghai Bestcovered Limited | Shanghai | Shanghai | Manufacturer | 2 |
Record
| Listed by | Abbott Laboratories, United States |
|---|---|
| FDA product code | JQP |
| Device type | Calculator/Data Processing Module, For Clinical Use |
| Device class | Class 1 |
| Regulation | 21 CFR 862.2100 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K093318 |
| Record published | 2023-09-15 |
| Record revised | 2025-06-11 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 07L0102 | In distribution | |
| 07L0101 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| SoftPathDx | SCC Soft Computer | 69 |
| SoftMolecular | SCC Soft Computer | 67 |
| SoftFlowCytometry | SCC Soft Computer | 67 |
| SoftBiochemistry | SCC Soft Computer | 67 |
| SoftCytogenetics | SCC Soft Computer | 67 |
| SoftMic | SCC Soft Computer | 65 |
| SoftLab | SCC Soft Computer | 64 |
| SoftTrack | SCC Soft Computer | 61 |
| SoftHLA | SCC Soft Computer | 61 |
| SoftGenomics | SCC Soft Computer | 51 |
| SoftGenePortal | SCC Soft Computer | 48 |
| SoftTotalQC | SCC Soft Computer | 28 |
Showing 12 of 140. All products under Calculator/Data Processing Module, For Clinical Use
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K790543 | 1979-05-03 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Abbott Laboratories | 510(k) number | 2018-09-07 | Class II | Component change control | The firm identified customer sites where modules which the safety pacemaker label is missing. Information regarding the label included in the Operations Manual has been updated to specify: 1) the risk of malfunction applies to anyone with a | 159 devices | 2021-02-02 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2008-10-27 | Not classified | Software design | When an ARCHITECT c16000 System is connected to an ACCELERATOR APS System, the software on the ACCELERATOR APS System may not generate an error warning when a Sample Presentation/Sample Queue error occurs, which could result in contaminatio | 15 units | 2009-12-02 |
| 2008-09-09 | Not classified | Device Design | ACCELERATOR APS Centrifuge Module being recalled due to potential for micro-cracks to form over time in the metal centrifuge rotor buckets that may cause the centrifuge buckets to disconnect from the rotor in the centrifuge during centrifug | 6 | 2010-10-04 |
| 2007-10-25 | Not classified | Software design | Sample/Patient Mis-identification: Two issues identified related to the ACCELERATOR Decision Manager (ADM), to include: 1) Sample Identification (SID) and/or Patient Identification (PID) numbers that contain more than 12 characters are trun | 19 units. | 2008-04-01 |
| 2007-10-10 | Not classified | Software design | Sample problems; Five issues identified related to software utilized by the ACCELERATOR APS System Input/Output Module, to include: Under three specific conditions, the post-aspiration radio-frequency identification (RF ID) read of the tube | 1 unit. | 2008-03-10 |
| 2007-05-15 | Not classified | Other | Product’s hinged lid can fall, if not fully opened as designed, representing a potential injury hazard to the operator. | 1 unit. | 2007-11-27 |
| 2003-11-17 | Not classified | Other | Sample Identification (SID) numbers of a bar coded sample may be truncated, or shortened, after being scanned by the bar code reader (e.g. an actual SID of 123456 is shortened to 1234) | 148 | 2004-10-28 |
| 2003-11-17 | Not classified | Other | Sample Identification (SID) numbers of a bar coded sample may be truncated, or shortened, after being scanned by the bar code reader (e.g. an actual SID of 123456 is shortened to 1234) | 223 | 2004-10-28 |
| 2003-09-30 | Not classified | Other | Audible alarm occurs before aspiration potentially resulting in operator injury or results assigned to wrong patient for STAT samples. | 133 | 2004-04-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.