UniPOC ™ Data Management System
Catalogue number 10732943, listed by Siemens Healthcare Diagnostics Inc, United States, under Calculator/Data Processing Module, For Clinical Use. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Zhejiang (2), Guangdong (2), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Zhejiang Gene Science Co., Ltd. | Shaoxing | Zhejiang | Manufacturer | 31 |
| Foshan Zike Technology Co., Ltd. | Foshan | Guangdong | Manufacturer | 9 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
| Shanghai Bestcovered Limited | Shanghai | Shanghai | Manufacturer | 2 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | JQP |
| Device type | Calculator/Data Processing Module, For Clinical Use |
| Device class | Class 1 |
| Regulation | 21 CFR 862.2100 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2022-11-22 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10732943 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| SoftPathDx | SCC Soft Computer | 69 |
| SoftMolecular | SCC Soft Computer | 67 |
| SoftFlowCytometry | SCC Soft Computer | 67 |
| SoftBiochemistry | SCC Soft Computer | 67 |
| SoftCytogenetics | SCC Soft Computer | 67 |
| SoftMic | SCC Soft Computer | 65 |
| SoftLab | SCC Soft Computer | 64 |
| SoftTrack | SCC Soft Computer | 61 |
| SoftHLA | SCC Soft Computer | 61 |
| SoftGenomics | SCC Soft Computer | 51 |
| SoftGenePortal | SCC Soft Computer | 48 |
| SoftTotalQC | SCC Soft Computer | 28 |
Showing 12 of 140. All products under Calculator/Data Processing Module, For Clinical Use
Recalls
10 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-11-29 | Class II | Device Design | There is a remote possibility CentraLink may download an order to the ADVIA Automation System without specifying the sample type. This can occur when an order is received from the LIS without a sample type, requiring that the sample type be | 3,893 units | 2018-06-07 |
| 2015-08-26 | Class II | Device Design | Software Issues. | 449 systems | 2020-03-24 |
| 2015-05-19 | Class II | Under Investigation by firm | Siemens Healthcare Diagnostics has determined that the sample query function that includes Instrument or Instrument Group as search criteria may not return all samples from the Dimension Vista systems if onboard aliquot support rules are co | 1941 | 2018-04-27 |
| 2015-04-29 | Class II | Software design | System Limitations and Software Issues related to the following features: Custom reference ranges, User-initiated sample and result actions, Auto-verification and quality control rules, and Sample reports. | 1355 | 2017-05-11 |
| 2014-12-16 | Class II | Under Investigation by firm | Enabling sending of preliminary/initial results on the ADVIA Chemistry XPT creates a risk that a critical result could be overwritten by the same result rather than showing the repeated result on CentraLink. A result could be erroneous and | 7 | 2016-10-27 |
| 2014-05-22 | Class III | Software design | RAPIDComm 5.0 Screen Layout will display incorrect test names | 6 systems | 2015-05-26 |
| 2014-05-20 | Class II | Device Design | Certain configuration parameters may cause the reference ranges to not hold results as expected and release them to the Laboratory Information System (LIS) that should have been held for manual review. | 336 | 2015-08-10 |
| 2013-10-30 | Class II | Software design | Under extremely rare circumstances, a patient result that had been previously disabled may be released without proper review. (Disabled Test in CentraLink System or Aptio System May Become Enabled in CentraLink System.) | 40 | 2014-12-15 |
| 2013-08-13 | Class II | Software design | May not perform as intended under certain conditions, causing the release of results to the Laboratory Information System (LIS) that should have been held for manual review due to auto-verification rules or the delay/omission of result tran | 1347 | 2014-12-02 |
| 2012-05-29 | Class II | Software design | When using the EasyLink Quality Control Package the system may not perform as intended for Multi-Rule QC violations [e.g., 2(2S), 4(1s) and 10x], unless configured using the instructions send with the Urgent Field Safety Notice. When this | 637 | 2014-04-10 |
| 2012-05-29 | Class II | Software design | When using the syngo Quality Control package the system may not perform as intended for Multi-Rule QC violation [e.g., 2(2S), 4(1s) and 10x], unless configured using the instructions on page 2 of the recall notification. QC status may not | 44 | 2014-04-10 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.