Aptima®
Aptima® BV assay, 100 test, box 2 of 2 (15°C to 30°C box). The Aptima® BV assay is an in vitro nucleic acid amplification test that utilizes real time transcription-mediated amplification…
Aptima® BV assay, 100 test, box 2 of 2 (15°C to 30°C box). The Aptima® BV assay is an in vitro nucleic acid amplification test that utilizes real time transcription-mediated amplification (TMA®) for detection and quantitation of ribosomal RNA from bacteria associated with bacterial vaginosis (BV), including Lactobacillus (L. gasseri, L. crispatus, and L. jensenii), Gardnerella vaginalis, and Atopobium vaginae.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (2), Shandong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hochuen Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 20 |
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
| Shenzhen Yhlo Biotech Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 19 |
| Wuhan Landing Intelligence Medical Co., Ltd. | Wuhan | Hubei | Manufacturer | 17 |
| Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. | Nantong | Jiangsu | Manufacturer | 11 |
| Xian Tianlong Science AND Technology Co., Ltd. | Xi’An | Shaanxi | Manufacturer | 8 |
| Xiamen Zeesan Biotech Co., Ltd. | Xiamen | Fujian | Manufacturer | 6 |
| Jiangsu Bioperfectus Technologies Co., Ltd. | Taizhou | Jiangsu | Manufacturer | 3 |
| Shanghai ZJ BIO-Tech Co., Ltd. | Shanghai | Shanghai | Private-label distributor | 3 |
Record
| Listed by | Hologic, Inc., United States |
|---|---|
| FDA product code | NSU |
| Device type | Instrumentation For Clinical Multiplex Test Systems |
| Device class | Class 2 |
| Regulation | 21 CFR 862.2570 |
| Establishment | Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K190452 |
| Record published | 2019-07-02 |
| Record revised | 2024-06-11 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| BV CALIBRATOR, APTIMA, 100T, IVD | In distribution | ||
| APTIMA LIQUID PAP TRANSFER TUBES, IVD KIT | In distribution | ||
| APTIMA URINE SPECIMEN COLLECTION KIT | 50 | In distribution | |
| KIT, BOX 1, REFRIGERATED, ACV/TV, 250T, IVD | In distribution | ||
| KIT, BOX 2, ROOM TEMP, ABV, 100T, IVD | In distribution | ||
| APTIMA SWAB SPECIMEN COLLECTION KIT | 50 | In distribution | |
| KIT, BOX 2, ROOM TEMP, ABV, 250T, IVD | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Spartan RX CYP2C19 System | Spartan Bioscience, Inc. | 10 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 8 |
| OpsisDx | Entopsis, Inc. | 5 |
| Affymetrix | Affymetrix, Inc. | 4 |
| FilmArray® 2.0 Instrument Ngds Configuration | BioFire Defense, LLC | 3 |
| FilmArray® 2.0 Instrument | BioFire Diagnostics, LLC | 3 |
| Opus | Bio-Rad Laboratories Inc. | 3 |
| FilmArray® Torch System Base | BioFire Diagnostics, LLC | 3 |
| FilmArray® Torch Module | BioFire Diagnostics, LLC | 3 |
| Biofire ® Spotfire ® Module | BioFire Diagnostics, LLC | 2 |
| Biofire ® Spotfire ® Control Station | BioFire Diagnostics, LLC | 2 |
| FilmArray® Instrument | BioFire Diagnostics, LLC | 2 |
Showing 12 of 110. All products under Instrumentation For Clinical Multiplex Test Systems
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2021-02-26 | Class II | Nonconforming Material/Component | There is a potential for tube trays to leak which could potentially result in false positive results, false negative results or invalid patient results. | 1355 kits | |
| 2020-08-04 | Class II | Under Investigation by firm | Tube trays may leak which could invalidate patient results or assay worklists, causing delayed results for any assays with which they are used. A possibility exists of false negative result with flu A/B/RSV assay or paraflu assay. | 607 | 2024-12-23 |
| 2018-01-20 | Class II | Device Design | The Panther or the Panther Fusion glass panel separates from the 19 inch touch screen monitor and could potentially fall and hit an operator. | 103 units | 2022-07-28 |
| 2017-09-15 | Class II | Employee error | An incorrect incubator was installed on one Panther System which potentially led to incorrect Aptima Combo 2(R) assay (AC2) results. | 1 unit | 2020-07-30 |