M2000
m2000sp SYSTEM SOFTWARE, Release 8.0
Who Else Makes It
Concentrated in Jiangsu (4), Shandong (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Orient Gene Biotech | Huzhou | Zhejiang | Contract manufacturer | 86 |
| Guangzhou Four E’s Scientific Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 61 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
| Infitek Co., Ltd. | Shanghai | Shanghai | Manufacturer | 49 |
| Labpeak Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
| Scitek Global Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
| Bioteke Corporation (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Manufacturer | 21 |
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
| Xian Tianlong Science AND Technology Co., Ltd. | Xi’An | Shaanxi | Manufacturer | 8 |
| Hangzhou Bioer Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 6 |
| Sansure Biotech Inc. | Changsha | Hunan | Manufacturer | 4 |
Showing 12 of 15. All 15 manufacturers in China registered for Real Time Nucleic Acid Amplification System
Record
| Listed by | Abbott Molecular, Inc., United States |
|---|---|
| FDA product code | OOI |
| Device type | Real Time Nucleic Acid Amplification System |
| Device class | Class 2 |
| Regulation | 21 CFR 862.2570 |
| Establishment | Specification developer, Manufacturer, Exporter |
| 510(k) | K092705 |
| Record published | 2016-09-01 |
| Record revised | 2025-07-14 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, serial number |
| Storage | Storage environment humidity 30 to 80 % RH; Storage environment temperature 15 to 30 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 9K15-01 | In distribution | |
| 4J71-75 | In distribution | |
| 08N88-001 | In distribution | |
| 08N89-001 | In distribution | |
| 4J71-70 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| GeneXpert Dx System | Cepheid | 37 |
| Alinity m | Abbott Molecular, Inc. | 20 |
| GeneXpert Infinity-80 System | Cepheid | 13 |
| Fluorescence Quantitative PCR Detection System | Anitoa Biotechnology(Hangzhou)Co., Ltd. | 12 |
| GeneXpert® | Cepheid | 10 |
| Certified Pre-Owned GeneXpert Dx System | Cepheid | 10 |
| Bioer GeneExplorer Thermal Cycler | Hangzhou Bioer Technology Co., Ltd. | 7 |
| GeneXpert Infinity-48s System | Cepheid | 5 |
| Panther Fusion® | Hologic, Inc. | 4 |
| Bioer LineGene 9600 Plus Fluorescent Quantitative Detection System | Hangzhou Bioer Technology Co., Ltd. | 4 |
| Bioer QuantGene 9600 Fluorescent Quantitative Detection System | Hangzhou Bioer Technology Co., Ltd. | 3 |
| Q-Vera Prima 96 qPCR Instrument | Sansure Biotech Inc. | 3 |
Showing 12 of 188. All products under Real Time Nucleic Acid Amplification System
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K092705 | 2010-05-28 |
Recalls Naming This Product
6 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Abbott Molecular, Inc. | 510(k) number | 2014-10-23 | Class II | Software design (manufacturing process) | Some versions of Application Specifications (App Spec) are incompatible with m2000sp system software version 6.0 and 7.0. This issue will cause Error Code 9000 (An unexpected error has occurred: Software error) to be generated when the Avai | 9 CD ROMs (US); 1,273 CD ROMs (Foreign) | 2016-03-08 |
| Abbott Molecular, Inc. | 510(k) number | 2014-06-19 | Class II | Employee error | Abbott Molecular identified that some of the 5 ml Reaction Vessels (RVs) contained in lots 56944001, 57026001, 57059001, and 57673001 (original vendor lot 2198077) may have an insufficient rim. An RV with an insufficient rim may not be held | 1,688,000 reaction vessels | 2016-02-23 |
| Abbott Molecular, Inc. | 510(k) number | 2013-11-23 | Class II | Nonconforming Material/Component | The x-drive assembly may fail prematurely. This could cause the manipulator or liquid handling arm to contact an object, shake and drip, or improperly pipet. | 176 devices | 2017-12-04 |
| Abbott Molecular, Inc. | 510(k) number | 2012-12-04 | Class II | Software design | An issue with the m2000sp Instrument software has been identified whereby, after a series of steps, if changes are made to the control or calibrator information on the Sample Extraction Assay Details screen, the changes are not saved. | 215 units – U.S., 693 units – ROW | 2016-03-08 |
| Abbott Molecular, Inc. | 510(k) number | 2011-10-11 | Not classified | Component design/selection | Abbott Molecular has received reports in which the liquid waste sensor and components in the m2000sp lower instrument cabinet overheated and/or caught fire. | 432 units | 2016-02-23 |
| Abbott Molecular, Inc. | 510(k) number | 2011-09-08 | Not classified | Software design | The Abbott m2000rt System software has software bug which can affect customers who manually enter a Test Order onto the m2000rt and sorts a column on the calibration or control grids of the Test Order screen by double clicking the column he | 926 units | 2016-03-08 |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-03-20 | Class II | Device Design | The design of the Alinity m System Solutions drawer enclosure may allow liquid (liquid waste or system solutions) originating in the System Solutions drawer to flow beyond the footprint of the instrument and into the walking-path of the use | ||
| 2024-03-20 | Class II | Under Investigation by firm | The Alinity m System camera detects whether tubes are “capped.” If the camera detects a cap and the retention bar is not present on the sample rack, the system will generate the message ‘Error – 6013: Has cap, no retention bar.” Abbott has | 1,012 units | |
| 2024-02-01 | Class III | Process control | Products that were intended for export only which were not approved or registered in accordance with U.S. specifications were shipped to U.S. customers. | ||
| 2022-12-09 | Class II | Under Investigation by firm | The firm identified the following three potential issues which may have impacted ADUs installed on distributed Alinity m Systems. 1. Systems which had their ADUs serviced may have an incorrect board value (calibration data file) referenced | 918 units | |
| 2022-11-11 | Class II | Under Investigation by firm | The instrument was found to be installed without plunger assemblies in the clamp bar for an Amplification Detection Unit. After correction of the issue, the instrument was returned for use without calibration. This would result in a poten | 1 | |
| 2022-10-12 | Class II | Under Investigation by firm | Abbott has identified potential performance issues for the Alinity m System software version 1.6.5: 1) In a unique scenario, the waste chute flapper was found to not open when the Systems Solution drawer was closed and locked. It was foun | 883 units | |
| 2022-02-11 | Class II | Under Investigation by firm | There is potential for the Reaction Vessels (RVs) detaching from the RV cap during transport by the pipettor robot. | 3063 kits | 2023-04-14 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.