CLIAwaived
Rapid Drug Test Cup for (THC50/COC150)(OPI300/MET500)(AMP500/BZO300)(BAR300/MTD300)(BUPG10/TCA1000)(MDMA500/OXY100)(PCP25/PPX300) + CR, NI, PH, BL, SG
Who Else Makes It
Concentrated in Zhejiang (6), Guangdong (2), Beijing (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Orient Gene Biotech | Huzhou | Zhejiang | Contract manufacturer | 86 |
| Hangzhou Biotest Biotech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 41 |
| Abon Biopharm (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 17 |
| Prometheus Bio Inc. | Hangzhou | Zhejiang | Contract manufacturer | 12 |
| Hangzhou AllTest Biotech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 48 |
| Assure Tech. (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 48 |
| W.h.p.m. Bioresearch & Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 37 |
| Guangzhou Decheng Biotechnology Co., Ltd. | Guangzhou | Guangdong | Complaint-file establishment | 35 |
| Changchun Wancheng BIO-Electron Co., Ltd. | Changchun | Jilin | Contract manufacturer | 34 |
| Co-Innovation Biotech Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 29 |
| Hongkong Conlight Medical Group Limited | Tai Kok Tsui | Hong Kong | Specification developer | 11 |
Record
| Listed by | Cliawaived,inc., United States |
|---|---|
| FDA product code | DJR |
| Device type | Enzyme Immunoassay, Methadone |
| Device class | Class 2 |
| Regulation | 21 CFR 862.3620 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K022355 |
| Record published | 2016-09-01 |
| Record revised | 2024-10-14 (version 10) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Over the counter | Yes |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 15 to 30 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CLIA-RDDT-52A | In distribution | |
| CLIA-IDTC-5-65569 | In distribution | |
| CLIA-IDTC-5-60579 | In distribution | |
| X07-CLIA-RDDT-88 | In distribution | |
| CLIA-14-RDTC-A | In distribution | |
| CLIA-RDDT-54 | In distribution | |
| CLIA-SDDT-20 | In distribution | |
| X07-CLIA-RDDT-70 | In distribution | |
| CLIA-IDTC-12BUPa | In distribution | |
| CLIA-SDDT-QF10 | In distribution | |
| CLIA-RDDT-52 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Healgen | Healgen Scientific Limited Liability Company | 56 |
| Identify Diagnostics Drug Test Cups | Medical Distribution Group Inc | 23 |
| DOA 5 Panel Test | Rapid Diagnostics, Inc. | 20 |
| Advin Multi-Drug Screen Test | Advin Biotech, Inc. | 14 |
| ProScreen | Instant Tech Subsidiary Acquisition | 13 |
| DrugCheck | Express Diagnostics Int’l., Inc. | 12 |
| UCP Compact Drug Test Cups | UCP Biosciences, Inc. | 12 |
| MD DugScreen | Medical Disposables Corp | 12 |
| QuickTox Drug Screen Dipcard | Branan Medical Corporation | 10 |
| U-Screen | Instant Tech Subsidiary Acquisition | 7 |
| First Sign® | Hemosure Inc. | 7 |
| Rtcii 2nd gen. | American Bio Medica Corp. | 7 |
Showing 12 of 170. All products under Enzyme Immunoassay, Methadone
Recalls Naming This Product
11 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Mckesson Medical-Surgical Inc. Corporate Office | 510(k) number | 2022-05-25 | Class II | Environmental control | Facility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lots received between 06/01/21-9/30/21. | a. unk b. 6 c. 1 d. 1 e. 67 f. 1 g. 10 h. 51 i. 27 j. 105 k. | |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 28,525 | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 120, 150 | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 31,600 units | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 108,000 units | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 31,800 units | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 13,700 units | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 136,925 units | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 189,175 units | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2020-08-18 | Class II | Process control | Various immunoassay enzymes failed product performance, thereby the products do not consistently detect all calibrator and secondary compounds at the levels stated in the labeling. | 47,005 units | 2024-09-30 |
| Ameditech, Inc. | 510(k) number | 2019-02-15 | Class III | Labeling mix-ups | Mixed Products containing QuickTox 5 Panel Drugs Screen Dipcard (P/N QT11, LOT #188787) and Alere iScreen Drugs of Abuse Dip Test (P/N X11-IS10-22015-DX LOT #188744) | 3400 units (136 kits) | 2021-04-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.