This dental device is a curing unit intended for polymerization of light-cured materials by dental professionals.
7manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
Who Else Makes It
Concentrated in Guangdong (3), Guangxi (2), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Premium Plus (Dongguan) Limited | Dongguan | Guangdong | Repacker / relabeller | 34 |
| Guilin Woodpecker Medical Instrument Co., Ltd. | Guilin | Guangxi | Manufacturer | 25 |
| Foshan Coxo Medical Instrument Co., Ltd. | Foshan | Guangdong | Manufacturer | 19 |
| Foshan Cicada Dental Instrument Co., Ltd. | Foshan | Guangdong | Manufacturer | 15 |
| Changzhou Sifary Medical Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 14 |
| Dentall, Inc. | District | Beijing | Contract manufacturer | 13 |
| Guilin Refine Medical Instrument Co., Ltd. | Guilin | Guangxi | Contract manufacturer | 7 |
Record
| Listed by | DXM Co., Ltd., South Korea |
|---|---|
| FDA product code | EBZ |
| Device type | Activator, Ultraviolet, For Polymerization |
| Device class | Class 2 |
| Regulation | 21 CFR 872.6070 |
| Establishment | Contract manufacturer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Record published | 2022-09-29 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Latex | Labelled latex-free |
| Label carries | manufacturing date, serial number |
| Storage | Handling environment temperature -5 to 40 °C; Handling environment humidity 10 to 85 % RH; Handling environment atmospheric pressure 80 to 106 KiloPascal; Storage environment temperature -10 to 45 °C; Storage environment humidity 10 to 90 % RH; Storage environment atmospheric pressure 60 to 106 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| SPEC3 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Valo | Ultradent Products Inc. | 59 |
| Woodpecker | Guilin Woodpecker Medical Instrument Co., Ltd. | 37 |
| Ledex | Dentmate Technology Co., Ltd. | 34 |
| Coltolux | Coltene/Whaledent Gmbh & Co. KG | 27 |
| Valo X | Ultradent Products Inc. | 22 |
| Spec 3 | Coltene/Whaledent Gmbh & Co. KG | 20 |
| Bluephase G4 | Ivoclar Vivadent Aktiengesellschaft | 20 |
| Aurora™ | Parkell, Inc. | 18 |
| DTE | Guilin Woodpecker Medical Instrument Co., Ltd. | 17 |
| D-LUX+ | Diadent Group Intl., Inc. | 16 |
| Apoza | Apoza Enterprise Co., Ltd. | 15 |
| Soleil | Benco Dental Supply Co. | 15 |
Showing 12 of 139. All products under Activator, Ultraviolet, For Polymerization
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K191221 | 2020-01-10 |
| K173876 | 2018-01-24 |
| K121093 | 2012-11-27 |
| K042703 | 2004-10-12 |