EM SA Implant (Narrow Ridge)
The EM SA Narrow Ridge Implant supports replacement teeth for missing mandibular central or lateral incisors in partially edentulous patients. It is intended to restore chewing function…
The EM SA Narrow Ridge Implant supports replacement teeth for missing mandibular central or lateral incisors in partially edentulous patients. It is intended to restore chewing function with a dental prosthesis. This implant is for single use and is intended for delayed loading.
The titanium alloy implant is placed surgically in the jawbone. Its threaded body provides the endosseous fixation component, while the coronal portion supports the replacement tooth. The surface is sandblasted and acid etched. It is supplied sterile.
Narrow Ridge Configuration
The Narrow Ridge family has thread diameters of 2.5 and 3.0 mm and several lengths. Its indication is specific to lower incisors, rather than the denture stabilization indication of the separate EM SA Denture configuration.
Who Else Makes It
Concentrated in Jiangsu (3), Sichuan (2), Shanghai (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Jiangsu Trausim Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Basic (Chengdu) Medical Device Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 1 |
| Dongguan Xinlonghong Hardware Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 1 |
| Chengdu Besmile Medical Technology Co., Ltd. | Chengdu | Sichuan | Manufacturer | 14 |
| BIO Concept Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 5 |
Record
| Listed by | Hiossen Inc., United States |
|---|---|
| FDA product code | DZE |
| Device type | Implant, Endosseous, Root-Form |
| Device class | Class 2 |
| Regulation | 21 CFR 872.3640 |
| Establishment | Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K191201 |
| Record published | 2019-12-19 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| EMN2513S40 | In distribution | |
| EMN2511S40 | In distribution | |
| EMN3008S25 | In distribution | |
| EMN2510S25 | In distribution | |
| EMN3010S25 | In distribution | |
| EMN2511S25 | In distribution | |
| EMN3008S40 | In distribution | |
| EMN3015S25 | In distribution | |
| EMN3013S40 | In distribution | |
| EMN3010S40 | In distribution | |
| EMN3011S25 | In distribution | |
| EMN2515S25 | In distribution | |
| EMN2513S25 | In distribution | |
| EMN3011S40 | In distribution | |
| EMN2510S40 | In distribution | |
| EMN2508S25 | In distribution | |
| EMN2508S40 | In distribution | |
| EMN2515S40 | In distribution | |
| EMN3015S40 | In distribution | |
| EMN3013S25 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Neodent | Jjgc Indústria e Comércio de Materiais Dentários S.A. | 920 |
| Osstem Implant System | Osstem Implant Co., Ltd. | 788 |
| Magicore | InnoBioSurg Co., Ltd.(IBS implant Co., Ltd.) | 744 |
| Implant, Endosseous, Root-Form | Southern Implants (PTY) Ltd | 608 |
| ITL Dental | Emery Enterprises Inc. | 603 |
| Magicore S | InnoBioSurg Co., Ltd.(IBS implant Co., Ltd.) | 560 |
| Friadent® | Dentsply Implants Manufacturing GmbH | 525 |
| Sphero Block Normo | Rhein 83 SRL | 489 |
| Neobiotech Implant System | Neobiotech Co., Ltd. | 483 |
| KJ Mini Implant System | Kjmeditech.co., Ltd. | 448 |
| Ritter Dental Implant System | Ritter Implants GmbH & Co. KG | 418 |
| Leone SPA | Leone SPA | 404 |
Showing 12 of 2,762. All products under Implant, Endosseous, Root-Form
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K240232 | 2024-09-13 |
| K203360 | 2022-01-07 |
| K191751 | 2019-12-16 |
| K191201 | 2019-11-15 |
| K183242 | 2019-05-21 |
| K153332 | 2016-10-27 |
| K151626 | 2016-07-21 |
| K140934 | 2014-11-12 |
| K123471 | 2013-07-05 |
| K112532 | 2012-08-06 |
| K103537 | 2011-03-10 |
| K101096 | 2010-10-08 |
| K093889 | 2010-04-22 |
| K093352 | 2009-11-24 |
| K090237 | 2009-04-17 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2023-04-06 | Class II | Labeling Change Control | Mis-labeled length of the dental implant on the Recall Implant’s package. Dental implant size D5.0 x L8.5mm, labeled as D5.0 x L10mm | 287 units |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P800035 | 2001-10-04 | PERI-OSS | Curasan AG |
| P860012 | 1988-10-28 | ALVEOFORM TM BIOGRAFT | Collagen Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.