SwishActive™ Implant
16 catalogue numbers from 944116, listed by Implant Direct Sybron Manufacturing LLC, United States, under Implant, Endosseous, Root-Form. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Sichuan (2), Shanghai (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Jiangsu Trausim Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Basic (Chengdu) Medical Device Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 1 |
| Dongguan Xinlonghong Hardware Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 1 |
| Chengdu Besmile Medical Technology Co., Ltd. | Chengdu | Sichuan | Manufacturer | 14 |
| BIO Concept Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 5 |
Record
| Listed by | Implant Direct Sybron Manufacturing LLC, United States |
|---|---|
| FDA product code | DZE |
| Device type | Implant, Endosseous, Root-Form |
| Device class | Class 2 |
| Regulation | 21 CFR 872.3640 |
| Establishment | Repacker / relabeller, Manufacturer |
| 510(k) | K130572 |
| Record published | 2015-09-14 |
| Record revised | 2024-12-20 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 944116 | 4.1mmD x 16mmL | In distribution |
| 944114 | 4.1mmD x 14mmL | In distribution |
| 944106 | 4.1mmD x 6mmL | In distribution |
| 944808 | 4.8mmD x 8mmL | In distribution |
| 944810 | 4.8mmD x 10mmL | In distribution |
| 943310 | 3.3mmD x 10mmL | In distribution |
| 943308 | 3.3mmD x 8mmL | In distribution |
| 944806 | 4.8mmD x 6mmL | In distribution |
| 944110 | 4.1mmD x 10mmL | In distribution |
| 944108 | 4.1mmD x 8mmL | In distribution |
| 943316 | 3.3mmD x 16mmL | In distribution |
| 944112 | 4.1mmD x 12mmL | In distribution |
| 944812 | 4.8mmD x 12mmL | In distribution |
| 943312 | 3.3mmD x 12mmL | In distribution |
| 944814 | 4.8mmD x 14mmL | In distribution |
| 943314 | 3.3mmD x 14mmL | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Neodent | Jjgc Indústria e Comércio de Materiais Dentários S.A. | 920 |
| Osstem Implant System | Osstem Implant Co., Ltd. | 788 |
| Magicore | InnoBioSurg Co., Ltd.(IBS implant Co., Ltd.) | 744 |
| Implant, Endosseous, Root-Form | Southern Implants (PTY) Ltd | 608 |
| ITL Dental | Emery Enterprises Inc. | 603 |
| Magicore S | InnoBioSurg Co., Ltd.(IBS implant Co., Ltd.) | 560 |
| Friadent® | Dentsply Implants Manufacturing GmbH | 525 |
| Sphero Block Normo | Rhein 83 SRL | 489 |
| Neobiotech Implant System | Neobiotech Co., Ltd. | 483 |
| KJ Mini Implant System | Kjmeditech.co., Ltd. | 448 |
| Ritter Dental Implant System | Ritter Implants GmbH & Co. KG | 418 |
| Leone SPA | Leone SPA | 404 |
Showing 12 of 2,762. All products under Implant, Endosseous, Root-Form
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K222211 | 2023-02-02 |
| K201553 | 2021-01-22 |
| K192221 | 2020-06-25 |
| K143011 | 2015-07-16 |
| K130572 | 2013-12-24 |
| K131097 | 2013-08-22 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Implant Direct Sybron Manufacturing LLC | 510(k) number | 2018-10-26 | Class II | Packaging | packaging error; An internal QA inspection revealed that a incorrect healing collar could have been packaged in an implant assembly kit. | 53 implants | |
| Implant Direct Sybron Manufacturing LLC | 510(k) number | 2018-03-14 | Class II | Labeling mix-ups | The cap on the vial might be labeled with the incorrect part number but the main vial label is correct. | 298 implants | 2018-06-04 |
| Implant Direct Sybron Manufacturing LLC | 510(k) number | 2017-03-03 | Class II | Process control | The main vial label lists the incorrect part number, but the cap label is correct. | 124 units | 2018-08-06 |
Recalls
16 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2021-09-23 | Class II | Packaging change control | Packaged dental implant contains a different size then the size declared on the labeling. | 61 implants | |
| 2021-09-23 | Class II | Packaging change control | Packaged dental implant contains a different size then the size declared on the labeling. | 83 implants | |
| 2019-10-11 | Class II | Mixed-up of materials/components | Through a customer complaint and and internal investigation it was determined that some implant packages contain the incorrect cover screw and extender. This could result in delay in surgery and/or a potential new surgical procedures to | 78 implants | 2024-04-12 |
| 2019-10-07 | Class II | Packaging process control | Some dental implant packages contain incorrect implants, which could lead to surgery rescheduling. | 72 | 2021-04-28 |
| 2019-08-09 | Class II | Packaging | A QA inspection confirmed that a Healing Collar (Part number 8735-15) was packaged instead of the Implant ordered. | 23 implants | 2021-04-27 |
| 2018-08-08 | Class II | Employee error | Two units in distribution were found to be mislabeled on the vial cap with the incorrect part number. | 22 vials | 2019-10-07 |
| 2018-08-07 | Class II | Employee error | The incorrect device was packaged in the vial. | 158 devices | |
| 2018-05-18 | Class II | Process control | Due to out of specification, the clinician would not be able to fit and engage the abutment with the implant | 60 units | 2020-07-13 |
| 2018-01-19 | Class II | Process control | The extender that is packaged with the SwishTapered” and SwishPlus” Implant may have been packaged in the incorrect position (upside down in the plastic retainer). | 1,117 units total | 2023-07-26 |
| 2017-10-10 | Class II | Process design | One reported complaint and discovered that the outer vial was out of round and undersized. Therefore a portion of the opening may not allow inner vial and components to slide freely out of the vial. As a result, the cap could possibly not | 75 units | 2018-09-27 |
| 2017-05-02 | Class II | Nonconforming Material/Component | Implant Direct Sybron Manufacturing is recalling the Legacy Full-Contour Abutment 3.5mmD Assembly because it may be out of Implant Direct specification. | 151 units | 2018-01-08 |
| 2016-12-12 | Class II | Packaging process control | The extender product code (9037-03) that is packaged with the SwishTapered (Part Number 933308; Lot Number 73241) Implant was packaged in the incorrect position. This discrepancy may lead to the possibility of extender not seating properly | 17 | 2017-05-22 |
| 2016-11-28 | Class II | Labeling mix-ups | Consignees received product 6060-62, Replant Overdenture Abutment with the label for 4500-61 GoDirect Screw-Retaining Top. | 14 | 2017-02-16 |
| 2016-11-15 | Class II | Labeling mix-ups | The vial cap was mislabeled with the incorrect part number of 855708 but the product description on the cap was correct. The main vial label was correctly labeled. | 18 units | 2018-06-04 |
| 2016-07-05 | Class II | Process control | Issue with design specification; oversized condition. | 205 | 2017-02-16 |
| 2016-03-04 | Class II | Nonconforming Material/Component | Implant Direct Sybron Manufacturing, LLC is recalling GoDirect Implants because some consignees did not receive the correct tool to drive the implant to bone level. | 2033 | 2016-05-17 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P800035 | 2001-10-04 | PERI-OSS | Curasan AG |
| P860012 | 1988-10-28 | ALVEOFORM TM BIOGRAFT | Collagen Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.