DIRECTarch™ Straight MultiUnit Tool

Catalogue number DA-MUATool, listed by Implant Direct Sybron Manufacturing LLC, United States, under Accessories, Implant, Dental, Endosseous. 70 manufacturers in China are registered for this product code.

Registry build 21.09.26
70manufacturers in China registered for this device type
1catalogue number
5recalls on this code

Who Else Makes It

Concentrated in Guangdong (28), Jiangsu (9), Zhejiang (6). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NDP
Manufacturer City Province Registered as Device types
Shenzhen Denco Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 52
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
iBrite Suzhou Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 18
Digital Dental Depot Zhuhai Guangdong Contract manufacturer 17
Xiamen Yizhou IMP. & EXP. Co., Ltd. Xiamen Fujian Contract manufacturer 10
Amedcon Medical Technology (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 7
Ningbo Sezen Technology Co., Ltd. Ningbo Zhejiang Contract manufacturer 7
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Debo Medical Technology (Shijiazhuang) Co., Ltd. Shijiazhuang Hebei Contract manufacturer 117
Shanghai Jolly Industrial Co., Ltd. Shanghai Shanghai Contract manufacturer 99
Shanghai Lions Industrial Co., Ltd. Shanghai Shanghai Contract manufacturer 82
Wuxi Lyusmile IMP AND EXP Co., Ltd. Wuxi Jiangsu Private-label distributor 66

Showing 12 of 70. All 70 manufacturers in China registered for Accessories, Implant, Dental, Endosseous

Record

Regulatory record for DIRECTarch™ Straight MultiUnit Tool
Listed by Implant Direct Sybron Manufacturing LLC, United States
FDA product code NDP
Device type Accessories, Implant, Dental, Endosseous
Device class Class 1
Regulation 21 CFR 872.3980
Establishment Repacker / relabeller, Manufacturer
Premarket notification Exempt
Record published 2023-05-15

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for DIRECTarch™ Straight MultiUnit Tool
Catalogue number Size Status
DA-MUATool In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Accessories, Implant, Dental, Endosseous Southern Implants (PTY) Ltd 1,379
Accessories, Implant, Dental, Endosseous Institut Straumann AG 1,320
Neobiotech Implant System Neobiotech Co., Ltd. 1,112
Inclusive Prismatik Dentalcraft, Inc. 1,045
Medentika Medentika GmbH 1,042
BioHorizons Biohorizons Implant Systems Inc. 1,008
IPD Implant Protesis Dental 2004 SL 998
Klockner Soadco, S.L. 995
Dynamic Abutment Solutions Talladium España, SL 877
Neodent Jjgc Indústria e Comércio de Materiais Dentários S.A. 738
Nobel Biocare® Nobel Biocare AB 703
MIS MIS Implants Technologies Ltd. 615

Showing 12 of 7,548. All products under Accessories, Implant, Dental, Endosseous

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-11-28 Class II Process control The peek part was loose on the titanium base of the device which could result in it falling into a patient’s mouth during a procedure resulting in aspiration or ingestion. 232 devices
2018-11-28 Class II Process control The peek part was loose on the titanium base of the device which could result in it falling into a patient’s mouth during a procedure resulting in aspiration or ingestion. 274 devices
2018-09-06 Class II Nonconforming Material/Component The action is being initiated due to incorrect assembly of the scan adapter. The result of the incorrect assembly could cause the clinician not to be able to capture the position and orientation of a dental implant(s) or lab analog during 107 Scan Adapters 2021-07-01
2018-05-29 Class II Process control Cap may be mislabeled with incorrect part number, although the correct part number is on the main vial label. 217 units 2020-07-29
2017-11-15 Class II Labeling mix-ups The Spectra System/Legacy Guided Surgery Handle Kit had guided handle inserts that were out of Implant Direct specifications, from the results of complaints submitted by clinicians regarding the 3.4mm guide insert that will not allow the 3. 560 units (worldwide) 2018-10-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer