Single Patient Quad Shaping Drill

Single Patient Quad Shaping Drill, 3.25mmD x 11.5mmL

Registry build 21.09.26
70manufacturers in China registered for this device type
20catalogue numbers in this listing
14recalls on this code

Who Else Makes It

Concentrated in Guangdong (28), Jiangsu (9), Zhejiang (6). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NDP
Manufacturer City Province Registered as Device types
Shenzhen Denco Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 52
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
iBrite Suzhou Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 18
Digital Dental Depot Zhuhai Guangdong Contract manufacturer 17
Xiamen Yizhou IMP. & EXP. Co., Ltd. Xiamen Fujian Contract manufacturer 10
Amedcon Medical Technology (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 7
Ningbo Sezen Technology Co., Ltd. Ningbo Zhejiang Contract manufacturer 7
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Debo Medical Technology (Shijiazhuang) Co., Ltd. Shijiazhuang Hebei Contract manufacturer 117
Shanghai Jolly Industrial Co., Ltd. Shanghai Shanghai Contract manufacturer 99
Shanghai Lions Industrial Co., Ltd. Shanghai Shanghai Contract manufacturer 82
Wuxi Lyusmile IMP AND EXP Co., Ltd. Wuxi Jiangsu Private-label distributor 66

Showing 12 of 70. All 70 manufacturers in China registered for Accessories, Implant, Dental, Endosseous

Record

Regulatory record for Single Patient Quad Shaping Drill
Listed by ZimVie US Corp LLC, United States
FDA product code NDP
Device type Accessories, Implant, Dental, Endosseous
Device class Class 1
Regulation 21 CFR 872.3980
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2025-12-18
Record revised 2026-01-15 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Single Patient Quad Shaping Drill
Catalogue number Size Status
SPQSD513 In distribution
SPQSD3215 In distribution
SPQSD611 In distribution
SPQSD511 In distribution
SPQSD410 In distribution
SPQSD613 In distribution
SPQSD615 In distribution
SPQSD485 In distribution
SPQSD610 In distribution
SPQSD3285 In distribution
SPQSD413 In distribution
SPQSD515 In distribution
SPQSD415 In distribution
SPQSD3210 In distribution
SPQSD3213 In distribution
SPQSD585 In distribution
SPQSD411 In distribution
SPQSD3211 In distribution
SPQSD510 In distribution
SPQSD685 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Accessories, Implant, Dental, Endosseous Southern Implants (PTY) Ltd 1,379
Accessories, Implant, Dental, Endosseous Institut Straumann AG 1,320
Neobiotech Implant System Neobiotech Co., Ltd. 1,112
Inclusive Prismatik Dentalcraft, Inc. 1,045
Medentika Medentika GmbH 1,042
BioHorizons Biohorizons Implant Systems Inc. 1,008
IPD Implant Protesis Dental 2004 SL 998
Klockner Soadco, S.L. 995
Dynamic Abutment Solutions Talladium España, SL 877
Neodent Jjgc Indústria e Comércio de Materiais Dentários S.A. 738
Nobel Biocare® Nobel Biocare AB 703
MIS MIS Implants Technologies Ltd. 615

Showing 12 of 7,548. All products under Accessories, Implant, Dental, Endosseous

Recalls

14 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-10-11 Class II Employee error The device may contain a manufacturing condition affecting the geometry of the driver’s hex feature which prevents it from properly engaging the fixture mount transfer and/or a dental implant. 356 units 2019-03-13
2017-10-11 Class II Employee error The device may contain a manufacturing condition affecting the geometry of the driver’s hex feature which prevents it from properly engaging the fixture mount transfer and/or a dental implant. 891 kits 2019-03-13
2017-10-11 Class II Employee error The device may contain a manufacturing condition affecting the geometry of the driver’s hex feature which prevents it from properly engaging the fixture mount transfer and/or a dental implant. 166 kits 2019-03-13
2017-10-11 Class II Employee error The device may contain a manufacturing condition affecting the geometry of the driver’s hex feature which prevents it from properly engaging the fixture mount transfer and/or a dental implant. 30 kits 2019-03-13
2017-07-10 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device field correction for various dental products due to several parts being shipped to the customer with only standard IFUs. All the products were missing supplemental IFUs. 76 products 2019-08-05
2017-07-10 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device field correction for various dental products due to several parts being shipped to the customer with only standard IFUs. All the products were missing supplemental IFUs. 86 products 2019-08-05
2017-07-10 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device field correction for various dental products due to several parts being shipped to the customer with only standard IFUs. All the products were missing supplemental IFUs. 423 products 2019-08-05
2017-07-10 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device field correction for various dental products due to several parts being shipped to the customer with only standard IFUs. All the products were missing supplemental IFUs. 349 products 2019-08-05
2015-11-16 Class II Software design (manufacturing process) Images contained within radiographic transparency ART 1036 are undersized. 686 2016-12-14
2015-09-21 Class II Process control Inadequate biocompatibility testing. 30,111 devices. 2016-10-12
2015-09-21 Class II Process control Inadequate biocompatibility testing. 30,111 devices. 2016-10-12
2015-08-10 Class II Labeling mix-ups RASQ3N, a square, abutment screw driver tip has been labeled and distributed as RASH3N, a hexed, abutment screw driver tip. Additionally, the RASQ3N received the RASH3N’s laser marking “RASH3N” during manufacturing. 103 pieces 2016-10-12
2015-08-10 Class II Labeling mix-ups The RASH3N, a hexed, abutment screw driver tip has been labeled and distributed as RASQ3N, a square, abutment screw driver tip. Additionally, the RASQ3N received the RASH3N’s laser marking “RASH3N” during manufacturing. 96 pieces 2016-10-12
2015-01-22 Class II Device Design The Gemlock Long Hex Driver may not fit into the Fixture Mount Transfer (FMT) or the internal hex of the implant. 627 units 2015-08-03

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer