Zirconia Abutment Preparation Kit
Catalogue number ZRPREP, listed by Implant Direct Sybron Manufacturing LLC, United States, under Accessories, Implant, Dental, Endosseous. 70 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (28), Jiangsu (9), Zhejiang (6). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shenzhen Denco Medical Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 52 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| iBrite Suzhou Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Digital Dental Depot | Zhuhai | Guangdong | Contract manufacturer | 17 |
| Xiamen Yizhou IMP. & EXP. Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 10 |
| Amedcon Medical Technology (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 7 |
| Ningbo Sezen Technology Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 7 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Debo Medical Technology (Shijiazhuang) Co., Ltd. | Shijiazhuang | Hebei | Contract manufacturer | 117 |
| Shanghai Jolly Industrial Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 99 |
| Shanghai Lions Industrial Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 82 |
| Wuxi Lyusmile IMP AND EXP Co., Ltd. | Wuxi | Jiangsu | Private-label distributor | 66 |
Showing 12 of 70. All 70 manufacturers in China registered for Accessories, Implant, Dental, Endosseous
Record
| Listed by | Implant Direct Sybron Manufacturing LLC, United States |
|---|---|
| FDA product code | NDP |
| Device type | Accessories, Implant, Dental, Endosseous |
| Device class | Class 1 |
| Regulation | 21 CFR 872.3980 |
| Establishment | Repacker / relabeller, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2015-12-29 |
| Record revised | 2020-03-23 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ZRPREP | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Accessories, Implant, Dental, Endosseous | Southern Implants (PTY) Ltd | 1,379 |
| Accessories, Implant, Dental, Endosseous | Institut Straumann AG | 1,320 |
| Neobiotech Implant System | Neobiotech Co., Ltd. | 1,112 |
| Inclusive | Prismatik Dentalcraft, Inc. | 1,045 |
| Medentika | Medentika GmbH | 1,042 |
| BioHorizons | Biohorizons Implant Systems Inc. | 1,008 |
| IPD | Implant Protesis Dental 2004 SL | 998 |
| Klockner | Soadco, S.L. | 995 |
| Dynamic Abutment Solutions | Talladium España, SL | 877 |
| Neodent | Jjgc Indústria e Comércio de Materiais Dentários S.A. | 738 |
| Nobel Biocare® | Nobel Biocare AB | 703 |
| MIS | MIS Implants Technologies Ltd. | 615 |
Showing 12 of 7,548. All products under Accessories, Implant, Dental, Endosseous
Recalls
5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-11-28 | Class II | Process control | The peek part was loose on the titanium base of the device which could result in it falling into a patient’s mouth during a procedure resulting in aspiration or ingestion. | 232 devices | |
| 2018-11-28 | Class II | Process control | The peek part was loose on the titanium base of the device which could result in it falling into a patient’s mouth during a procedure resulting in aspiration or ingestion. | 274 devices | |
| 2018-09-06 | Class II | Nonconforming Material/Component | The action is being initiated due to incorrect assembly of the scan adapter. The result of the incorrect assembly could cause the clinician not to be able to capture the position and orientation of a dental implant(s) or lab analog during | 107 Scan Adapters | 2021-07-01 |
| 2018-05-29 | Class II | Process control | Cap may be mislabeled with incorrect part number, although the correct part number is on the main vial label. | 217 units | 2020-07-29 |
| 2017-11-15 | Class II | Labeling mix-ups | The Spectra System/Legacy Guided Surgery Handle Kit had guided handle inserts that were out of Implant Direct specifications, from the results of complaints submitted by clinicians regarding the 3.4mm guide insert that will not allow the 3. | 560 units (worldwide) | 2018-10-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.