Implant Prosthetics

NobelActive™/Conical-compatible RP Non-Engaging Verification Cylinder Kit contains: 1 NobelActive™/Conical-compatible RP Non-Engaging Verification Cylinder 1 NobelActive™/Conical-compatible…

Registry build 21.09.26

NobelActive™/Conical-compatible RP Non-Engaging Verification Cylinder Kit contains: 1 NobelActive™/Conical-compatible RP Non-Engaging Verification Cylinder 1 NobelActive™/Conical-compatible RP Guide Pin 20mm 1 NobelActive™/Conical-compatible RP Titanium Implant Screw

15manufacturers in China registered for this device type
750catalogue numbers in this listing
3510(k) clearances naming this product code
9recalls on this code

Who Else Makes It

Concentrated in Guangdong (11), Jiangsu (2), Shanghai (1). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NHA
Manufacturer City Province Registered as Device types
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Modern Dental Laboratory (DG) Co., Ltd. Dongguan Guangdong Contract manufacturer 15
Exceldent Dental Technology Development Co., Ltd. Zhuhai Guangdong Contract manufacturer 12
DTS Digital Dental LAB Shenzhen Guangdong Contract manufacturer 11
KTJ Medical Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Shimmer Computerized Dental Technology Co., Ltd. Zhuhai Guangdong Contract manufacturer 10
Zhuhai Crystal Dental Technology Co., Ltd. Zhuhai Guangdong Contract manufacturer 9
NEW Perfect Dental LAB Shenzhen Guangdong Contract manufacturer 8
Shenzhen Jiahong Dental Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 7
Jiangsu Trausim Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Chengdu Besmile Medical Technology Co., Ltd. Chengdu Sichuan Manufacturer 14
CBD Dental LAB, Inc Shenzhen Guangdong Manufacturer 11

Showing 12 of 15. All 15 manufacturers in China registered for Abutment, Implant, Dental, Endosseous

Record

Regulatory record for Implant Prosthetics
Listed by Preat Corporation, United States
FDA product code NHA
Device type Abutment, Implant, Dental, Endosseous
Device class Class 2
Regulation 21 CFR 872.3630
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K183518
Record published 2016-09-16
Record revised 2024-02-19 (version 13)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Packaging Pack of 10, pack of 100, pack of 25, pack of 50
Distribution end date 2026-06-08

Catalogue Numbers

Catalogue numbers for Implant Prosthetics
Catalogue number Size Status
8000885 In distribution
8001873 In distribution
9002289 In distribution
8001780 In distribution
9004478 In distribution
8001086 In distribution
9000977 In distribution
8000562 In distribution
8004470 In distribution
8001489 In distribution
8001470 In distribution
8000220 In distribution
8000120 In distribution
9005054 In distribution
8002062 In distribution
8002259 In distribution
8001781 In distribution
8002175 In distribution
8005180 In distribution
9004419 In distribution
8005070 In distribution
8000676 In distribution
8000579 In distribution
8003362 In distribution
9002177 In distribution
8005185 In distribution
8000459 In distribution
9000930 In distribution
8003361 In distribution
8003385 In distribution
8000586 In distribution
9004425 In distribution
9001489 In distribution
8001570 In distribution
8002180 In distribution
9001575 In distribution
8001325 In distribution
9004429 In distribution
8000989 In distribution
8000520 In distribution
8003261 In distribution
8004762 In distribution
9001554 In distribution
9004178 In distribution
9003763 In distribution
9000189 In distribution
8001870 In distribution
8000581 In distribution
8005075 In distribution
8005189 In distribution
9001777 In distribution
8000880 In distribution
8004873 In distribution
9001254 In distribution
8005173 In distribution
8003381 In distribution
8002271 In distribution
8000461 In distribution
8000759 In distribution
9000830 In distribution
8004862 In distribution
8001485 In distribution
9005480 In distribution
8000175 In distribution
8001680 In distribution
8003477 In distribution
9001476 In distribution
8003562 In distribution
9005180 In distribution
8002825 In distribution
8003377 In distribution
8000470 In distribution
8005061 In distribution
8000886 In distribution
9000976 In distribution
8001581 In distribution
8004871 In distribution
8000359 In distribution
8003459 In distribution
8000271 In distribution
8003487 In distribution
9001877 In distribution
8003561 In distribution
8001089 In distribution
8001486 In distribution
8001776 In distribution
8000559 In distribution
9003757-10 In distribution
8000670 In distribution
9001680 In distribution
8003473 In distribution
8003471 In distribution
9005580 In distribution
9000730-10 In distribution
9002150 In distribution
8004850 In distribution
9003751 In distribution
8005186 In distribution
9000580 In distribution
9000978 In distribution
8000283 In distribution
8002286 In distribution
8000972 In distribution
9003756 In distribution
9004482 In distribution
9000980 In distribution
8001450-10 In distribution
9001781 In distribution
8003476 In distribution
8000761 In distribution
8001477 In distribution
8001677 In distribution
9001881 In distribution
8000277 In distribution
8000971 In distribution
9003757 In distribution
8003662 In distribution
8001675 In distribution
9004421 In distribution
8000925 In distribution
8000870 In distribution
9001959 In distribution
9000935 In distribution
8001220 In distribution
9004428 In distribution
9004426 In distribution
8004759 In distribution
8004489 In distribution
9001779 In distribution
8002262 In distribution
9000475 In distribution
8005077 In distribution
8004858 In distribution
9004150 In distribution
8000450 In distribution
8003472 In distribution
9003730 In distribution
8004477 In distribution
8000276 In distribution
8000275 In distribution
9000677 In distribution
9000454 In distribution
8003376 In distribution
8004972 In distribution
8005072 In distribution
9005361 In distribution
9004189 In distribution
8001473 In distribution
8001092 In distribution
9005350 In distribution
9005650 In distribution
9005380 In distribution
8001650-10 In distribution
8000420 In distribution
8002920 In distribution
8003576 In distribution
8001478 In distribution
8005172 In distribution
9000579 In distribution
8002275 In distribution
8002061 In distribution
8000825 In distribution
9003754 In distribution
9004450 In distribution
8005086 In distribution
9000477 In distribution
8000720 In distribution
9001780 In distribution
8000587 In distribution
9004430 In distribution
8000980 In distribution
8000272 In distribution
8001786 In distribution
8001471 In distribution
8000176 In distribution
9004483 In distribution
9001475 In distribution
9002050 In distribution
8001773 In distribution
8003721 In distribution
9000889 In distribution
9000476 In distribution
9005050 In distribution
9005461 In distribution
9001250 In distribution
9000481 In distribution
8001880 In distribution
9004177 In distribution
8000859 In distribution
9004422 In distribution
8004787 In distribution
8002150-10 In distribution
8001962 In distribution
9000981 In distribution
8000449 In distribution
8000889 In distribution
8003571 In distribution
9005289 In distribution
8004786 In distribution
9004420 In distribution
9005150 In distribution
8002273 In distribution
8005089 In distribution
9005076 In distribution
8003380 In distribution
9001650 In distribution
8004863 In distribution
8003575 In distribution
9002261 In distribution
8000677 In distribution
9001478 In distribution
8000976 In distribution
8004771 In distribution
8001059 In distribution
8000975 In distribution
8002172 In distribution
9004454 In distribution
8001875 In distribution
9005176 In distribution
8002285 In distribution
9000180 In distribution
9000589 In distribution
9000554 In distribution
8003371 In distribution
9000880 In distribution
8001580 In distribution
8001361 In distribution
8002071 In distribution
8003250 In distribution
8003489 In distribution
8000285 In distribution
8003375 In distribution
9002175 In distribution
9007050 In distribution
9004423 In distribution
9000283 In distribution
8004478 In distribution
9005389 In distribution
9005561 In distribution
9005259 In distribution
9004427 In distribution
9000950 In distribution
8005081 In distribution
8001876 In distribution
8002261 In distribution
8002281 In distribution
8000571 In distribution
8001575 In distribution
8004859 In distribution
9004180 In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
MEDENTiKA Medentika GmbH 2,553
LW Vis Abutment Ossvis Co., Ltd. 2,520
Dess dental smart solutions Terrats Medical SL 1,715
Locator Zest Anchors, LLC 1,643
NobelProcera® Nobel Biocare AB 1,526
Azure Terrats Medical SL 1,360
Neodent Jjgc Indústria e Comércio de Materiais Dentários S.A. 1,308
LW Vis Abutment SET Ossvis Co., Ltd. 1,260
Abutment, Implant, Dental, Endosseous Southern Implants (PTY) Ltd 1,240
Healing Abutment Megagen Implant Co., Ltd. 1,218
Chaorum Implant System Medimecca Co Ltd 1,084
OT Equator Rhein 83 SRL 1,051

Showing 12 of 6,204. All products under Abutment, Implant, Dental, Endosseous

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K243824 2025-05-08
K220823 2022-10-26
K183518 2019-03-18

Recalls Naming This Product

9 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Implant Prosthetics
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Preat Corporation 510(k) number 2025-06-25 Class II Process control Engaging titanium base was manufactured 180 degrees around the post from where it should be located in relation to the connection geometry; if the flat is on the wrong side of the post, the crown will not fit onto the abutment in the correc 11
Preat Corporation 510(k) number 2025-06-24 Class II Employee error Due to manufacturing error, digital analog rotational feature is 180 degrees off. 44 units
Preat Corporation 510(k) number 2025-04-02 Class II Process control Due to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a shorter engagement length into the associated implant. 145 abutments
Preat Corporation 510(k) number 2024-04-10 Class II Process control Due to incorrect milled titanium abutment being packaged and labeled. 7 abutmens
Preat Corporation 510(k) number 2024-02-09 Class II Process change control Due to a manufacturing issue, the screw seat location on the abutment product may be too high, causing mating screw to have a shorter engagement length into the associated implant. 561 units
Preat Corporation 510(k) number 2023-07-18 Class II Process change control The healing abutments contain a dimensional condition that may lead to a gap between the healing abutment and the implant allowing for microleakage 13 units
Preat Corporation 510(k) number 2023-07-18 Class II Process change control The healing abutments contain a dimensional condition that may lead to a gap between the healing abutment and the implant allowing for microleakage 23 units
Preat Corporation 510(k) number 2023-07-18 Class II Process change control The healing abutments contain a dimensional condition that may lead to a gap between the healing abutment and the implant allowing for microleakage 4 units
Preat Corporation 510(k) number 2023-02-21 Class II Process design Engaging titanium base contains a dimensional condition that allows vertical movement of the titanium base after the prosthetic screw is torqued to the recommended value, which if undetected and installed on the implant, may lead to abutmen 26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer