Preat

NobelBiocare™ Tri-Lobe-compatible 6.0 mm Titanium Blank Kit contains 1 NobelBiocare™ Tri-Lobe-compatible 6.0 mm Titanium Blank. 2 NobelBiocare™ Tri-Lobe-compatible RP/5.0mm/6.0mm Titanium…

Registry build 21.09.26

NobelBiocare™ Tri-Lobe-compatible 6.0 mm Titanium Blank Kit contains 1 NobelBiocare™ Tri-Lobe-compatible 6.0 mm Titanium Blank. 2 NobelBiocare™ Tri-Lobe-compatible RP/5.0mm/6.0mm Titanium Implant Screws

2manufacturers in China registered for this device type
46catalogue numbers in this listing

Who Else Makes It

All of them in Guangdong. 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code PNP
Manufacturer City Province Registered as Device types
Exceldent Dental Technology Development Co., Ltd. Zhuhai Guangdong Contract manufacturer 12
Shimmer Computerized Dental Technology Co., Ltd. Zhuhai Guangdong Contract manufacturer 10

Record

Regulatory record for Preat
Listed by Preat Corporation, United States
FDA product code PNP
Device type Dental Abutment Design Software For Dental Laboratory
Device class Class 2
Regulation 21 CFR 872.3630
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K183518
Record published 2025-06-10
Record revised 2025-06-27 (version 7)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, manufacturing date
Packaging Inner pack

Catalogue Numbers

Catalogue numbers for Preat
Catalogue number Size Status
9005765 In distribution
9000265 In distribution
9006665 In distribution
9001865 In distribution
9002265 In distribution
9005965 In distribution
9004165 In distribution
9006865 In distribution
9007565 In distribution
9001565 In distribution
9000465 In distribution
9005065 In distribution
9007165 In distribution
9008565 In distribution
9000865 In distribution
9000165 In distribution
9006465 In distribution
9005365 In distribution
9001765 In distribution
9000767 In distribution
9006765 In distribution
9001965 In distribution
9006565 In distribution
9000765 In distribution
9000565 In distribution
9000567 In distribution
9000965 In distribution
9001665 In distribution
9007265 In distribution
9002165 In distribution
9000365 In distribution
9005465 In distribution
9004765 In distribution
9000667 In distribution
9005265 In distribution
9005665 In distribution
9004465 In distribution
9002065 In distribution
9001465 In distribution
9000665 In distribution
9005565 In distribution
9005865 In distribution
9001265 In distribution
9000467 In distribution
9005165 In distribution
9007065 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
IPD Implant Protesis Dental 2004 SL 317
BruxZir® Prismatik Dentalcraft, Inc. 62
MEDENTiKA Medentika GmbH 36
Cerec Tessera Degudent Gmbh 15
BioHorizons Biohorizons Implant Systems Inc. 10
Nobel Biocare N1™ Nobel Biocare AB 10
CAD/CAM Software Sirona Dental Systems Gmbh 9
Dental Abutment Design Software For Dental Laboratory Nobel Biocare AB 7
Cerec Degudent Gmbh 6
Preat Implant Prosthetics Preat Corporation 4
DTX Studio™ Lab Nobel Biocare AB 4
AbutmentCAD Exocad Gmbh 4

Showing 12 of 19. All products under Dental Abutment Design Software For Dental Laboratory

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Preat
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Preat Corporation 510(k) number 2025-06-25 Class II Process control Engaging titanium base was manufactured 180 degrees around the post from where it should be located in relation to the connection geometry; if the flat is on the wrong side of the post, the crown will not fit onto the abutment in the correc 11
Preat Corporation 510(k) number 2025-04-02 Class II Process control Due to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a shorter engagement length into the associated implant. 145 abutments
Preat Corporation 510(k) number 2024-02-09 Class II Process change control Due to a manufacturing issue, the screw seat location on the abutment product may be too high, causing mating screw to have a shorter engagement length into the associated implant. 561 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer