Ormco
Crimpable Stop 2MM 19 I.D. X 30 O.D. PK40
Who Else Makes It
Concentrated in Zhejiang (19), Guangdong (11), Jiangsu (9). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shenzhen Denco Medical Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 52 |
| Sino Ortho Limited | Hangzhou | Zhejiang | Contract manufacturer | 14 |
| Hangzhou Westlake Biomaterial Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 13 |
| Chengdu Sani Medical Equipment Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 12 |
| Hangzhou Xingchen 3B Dental Instrument & Materials Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 7 |
| Yancheng Denrum Medical Apparatus Co., Ltd. | Yancheng | Jiangsu | Contract manufacturer | 5 |
| Debo Medical Technology (Shijiazhuang) Co., Ltd. | Shijiazhuang | Hebei | Contract manufacturer | 117 |
| Wuxi Lyusmile IMP AND EXP Co., Ltd. | Wuxi | Jiangsu | Private-label distributor | 66 |
| Shanghai MU Promotions Co., Ltd. | Shanghai | Shanghai | Exporter | 62 |
| Guangzhou Four E’s Scientific Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 61 |
| Hubei Guarddent Medical Technology Co., Ltd. | Wuhan | Hubei | Manufacturer | 60 |
| Tribest Dental Products Co Ltd | Yangzhong | Jiangsu | Contract manufacturer | 58 |
Showing 12 of 52. All 52 manufacturers in China registered for Bracket, Metal, Orthodontic
Record
| Listed by | Ormco Corporation, United States |
|---|---|
| FDA product code | EJF |
| Device type | Bracket, Metal, Orthodontic |
| Device class | Class 1 |
| Regulation | 21 CFR 872.5410 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2022-12-09 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
| Sizes | Length 2 to 4.5 mm; length 0.125 in |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 348-2101 | Slot size 022, Torque 22, Angulation 5 | 10 | In distribution |
| 610-0003 | In distribution | ||
| 600-1003 | 3MM | 10 | In distribution |
| 088-4023 | Large | In distribution | |
| 704-6031 | 100 | In distribution | |
| 300-0120 | In distribution | ||
| 663-0222 | Size 022 X 028 inches, Length 2 mm | 10 | In distribution |
| 242-0004 | In distribution | ||
| 088-4065 | Small | In distribution | |
| 704-4014 | 25 | In distribution | |
| 600-1001 | 1MM | 10 | In distribution |
| 367-0047 | Slot size 018, Torque 9, Angulation 0 | 10 | In distribution |
| 625-2228 | Length 4.5 mm | In distribution | |
| 100-3018 | Slot size 018 | In distribution | |
| 704-9000 | 50 | In distribution | |
| 367-0046 | Slot size 018, Torque 9, Angulation 0 | 10 | In distribution |
| 624-1825 | Length 2 mm | In distribution | |
| 613-0012 | In distribution | ||
| 623-0251 | Length 2 mm | In distribution | |
| 600-1004 | 4MM | 10 | In distribution |
| 610-0010 | In distribution | ||
| 600-1002 | 2MM | 10 | In distribution |
| 661-0022 | Size 022 inches, Length 2 mm | 10 | In distribution |
| 624-2228 | Length 2 mm | In distribution | |
| 088-4066 | Large | In distribution | |
| 242-0005 | Short | In distribution | |
| 100-1022 | Slot size 022 | In distribution | |
| 350-0000 | 10 | In distribution | |
| 663-0218 | Size 018 X 025 inches, Length 2 mm | 10 | In distribution |
| 628-1825 | Length.125 in | In distribution | |
| 399-0001 | Slot size 022, Torque -22, Angulation 0 | 10 | In distribution |
| 613-0010 | In distribution | ||
| 623-0262 | 019 ID X 030 OD | 40 | In distribution |
| 088-4024 | Small | In distribution | |
| 623-0263 | 030 ID X 041 OD | 40 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Leone SPA | Leone SPA | 2,306 |
| BioQuick® | Forestadent Bernhard Förster GmbH | 1,842 |
| Mini Master Series | American Orthodontics | 1,505 |
| Mini-Mono® | Forestadent Bernhard Förster GmbH | 1,225 |
| LP Low Profile | American Orthodontics | 1,204 |
| Mini Sprint® | Forestadent Bernhard Förster GmbH | 1,193 |
| Empower Bracket | American Orthodontics | 1,175 |
| Legend | GC Orthodontics America Inc. | 1,098 |
| Master Series | American Orthodontics | 1,084 |
| Experience® | GC Orthodontics America Inc. | 770 |
| The Orthodontic Store | Young Innovations Inc. | 658 |
| equilibrium® | Dentaurum GmbH & Co. KG | 646 |
Showing 12 of 876. All products under Bracket, Metal, Orthodontic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K922806 | 1993-10-20 |
| K923405 | 1993-05-05 |
| K914616 | 1991-11-20 |
| K900184 | 1990-04-02 |
| K894358 | 1989-09-15 |
| K894781 | 1989-09-15 |
| K892704 | 1989-06-12 |
| K870536 | 1987-02-19 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2009-02-13 | Not classified | Process control | The recall was initiated because Ormco has confirmed that manufacturing error resulted in the Orthos CM Brackets being incorrectly manufactured with a torque of -9. The packaging was labeled with +9 torque; however the brackets contained in | 304 units | 2012-03-02 |
| 2004-11-18 | Not classified | Other | Misassembly. Stainless steel and titanium parts were mistakenly welded together to construct the device. The weld failed. | 6,257 | 2005-06-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.