Twin

L4 and 5R TWIN BKT 22 ANDREWS T3 PA -2/-22/6

Registry build 21.09.26
52manufacturers in China registered for this device type
74catalogue numbers in this listing
8510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Zhejiang (19), Guangdong (11), Jiangsu (9). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code EJF
Manufacturer City Province Registered as Device types
Shenzhen Denco Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 52
Sino Ortho Limited Hangzhou Zhejiang Contract manufacturer 14
Hangzhou Westlake Biomaterial Co., Ltd. Hangzhou Zhejiang Contract manufacturer 13
Chengdu Sani Medical Equipment Co., Ltd. Chengdu Sichuan Contract manufacturer 12
Hangzhou Xingchen 3B Dental Instrument & Materials Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Yancheng Denrum Medical Apparatus Co., Ltd. Yancheng Jiangsu Contract manufacturer 5
Debo Medical Technology (Shijiazhuang) Co., Ltd. Shijiazhuang Hebei Contract manufacturer 117
Wuxi Lyusmile IMP AND EXP Co., Ltd. Wuxi Jiangsu Private-label distributor 66
Shanghai MU Promotions Co., Ltd. Shanghai Shanghai Exporter 62
Guangzhou Four E’s Scientific Co., Ltd. Guangzhou Guangdong Contract manufacturer 61
Hubei Guarddent Medical Technology Co., Ltd. Wuhan Hubei Manufacturer 60
Tribest Dental Products Co Ltd Yangzhong Jiangsu Contract manufacturer 58

Showing 12 of 52. All 52 manufacturers in China registered for Bracket, Metal, Orthodontic

Record

Regulatory record for Twin
Listed by Ormco Corporation, United States
FDA product code EJF
Device type Bracket, Metal, Orthodontic
Device class Class 1
Regulation 21 CFR 872.5410
Establishment Specification developer, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2022-12-07

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Twin
Catalogue number Size Per pack Status
164-1045 Slot size 022, Torque 2, Angulation -22 10 In distribution
164-1102 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
170-0127 Slot size 022, Torque -22 10 In distribution
163-1086 Slot size 018, Torque 0, Angulation -17, Rotation 4 10 In distribution
170-0123 Slot size 022, Torque -17 10 In distribution
164-1130 Slot size 022, Torque 2, Angulation -7 10 In distribution
163-1035 Slot size 018, Torque -1, Angulation -30, Rotation 4 10 In distribution
170-0110 Slot size 018, Torque -7 10 In distribution
163-1001 Slot size 018, Torque 2, Angulation -17 10 In distribution
170-0128 Slot size 018, Torque -22 10 In distribution
164-1100 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
163-1060 Slot size 018, Torque 0, Angulation -17 10 In distribution
163-1159 Slot size 018, Torque 0, Angulation -22 10 In distribution
164-1054 Slot size 022, Torque 2, Angulation -17 10 In distribution
170-0211 Slot size 022, Torque -11 10 In distribution
164-1086 Slot size 022, Torque -1, Angulation -22, Rotation 4 10 In distribution
163-1043 Slot size 018, Torque 0, Angulation -14, Rotation 14 10 In distribution
170-0114 Slot size 018, Torque -11 10 In distribution
164-1165 Slot size 022, Torque -2, Angulation -22, Rotation 6 10 In distribution
164-1028 Slot size 022, Torque 11, Angulation -7 10 In distribution
164-1110 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
164-1056 Slot size 022, Torque -1, Angulation -17, Rotation 4 10 In distribution
164-1107 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
170-0107 Slot size 022, Torque -7 10 In distribution
170-0109 Slot size 022, Torque -7 10 In distribution
164-1087 Slot size 022, Torque -1, Angulation -22, Rotation 4 10 In distribution
164-1147 Slot size 022, Torque 2, Angulation -7 10 In distribution
164-1051 Slot size 022, Torque 2, Angulation -17 10 In distribution
164-1053 Slot size 022, Torque -1, Angulation -17, Rotation 4 10 In distribution
163-1039 Slot size 018, Torque 0, Angulation -17 10 In distribution
164-1161 Slot size 022, Torque -2, Angulation -22, Rotation 6 10 In distribution
163-1079 Slot size 018, Torque 0, Angulation -7, Rotation 2 10 In distribution
163-1036 Slot size 018, Torque 0, Angulation -1 10 In distribution
164-1040 Slot size 022, Torque 2, Angulation -22 10 In distribution
164-1106 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
170-0119 Slot size 022, Torque -17 10 In distribution
164-1163 Slot size 022, Torque -2, Angulation -22, Rotation 6 10 In distribution
164-1083 Slot size 022, Torque 2, Angulation -22 10 In distribution
170-0117 Slot size 022, Torque -11 10 In distribution
164-1151 Slot size 022, Torque 2, Angulation -7 10 In distribution
164-1078 Slot size 022, Torque -1, Angulation -17, Rotation 4 10 In distribution
163-1065 Slot size 018, Torque 0, Angulation -22 10 In distribution
170-0120 Slot size 018, Torque -17 10 In distribution
163-1037 Slot size 018, Torque 0, Angulation -14, Rotation 14 10 In distribution
170-0113 Slot size 022, Torque -11 10 In distribution
163-1064 Slot size 018, Torque 0, Angulation -7, Rotation 2 10 In distribution
164-1115 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
164-1047 Slot size 022, Torque -1, Angulation -22, Rotation 4 10 In distribution
163-1005 Slot size 018, Torque 2, Angulation -17 10 In distribution
163-1058 Slot size 018, Torque 0, Angulation -7, Rotation 2 10 In distribution
170-0122 Slot size 018, Torque -17 10 In distribution
163-1066 Slot size 018, Torque 0, Angulation -7, Rotation 2 10 In distribution
170-0129 Slot size 022, Torque -22 10 In distribution
170-0124 Slot size 018, Torque -17 10 In distribution
163-1026 Slot size 018, Torque 2, Angulation -22 10 In distribution
170-0115 Slot size 022, Torque -11 10 In distribution
170-0108 Slot size 018, Torque -7 10 In distribution
164-1108 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
164-1043 Slot size 022, Torque -1, Angulation -22, Rotation 4 10 In distribution
164-1114 Slot size 022, Torque 0, Angulation -7, Rotation 2 10 In distribution
164-1079 Slot size 022, Torque 2, Angulation -17 10 In distribution
164-1090 Slot size 022, Torque -1, Angulation -22, Rotation 4 10 In distribution
170-0116 Slot size 018, Torque -11 10 In distribution
164-1125 Slot size 022, Torque 2, Angulation -7 10 In distribution
170-0121 Slot size 022, Torque -17 10 In distribution
164-1081 Slot size 022, Torque -1, Angulation -17, Rotation 4 10 In distribution
164-1076 Slot size 022, Torque 2, Angulation -17 10 In distribution
170-0111 Slot size 022, Torque -7 10 In distribution
164-1088 Slot size 022, Torque 2, Angulation -22 10 In distribution
164-1044 Slot size 022, Torque -1, Angulation -22, Rotation 4 10 In distribution
163-1031 Slot size 018, Torque 0, Angulation -1 10 In distribution
164-1159 Slot size 022, Torque -2, Angulation -22, Rotation 6 10 In distribution
163-1029 Slot size 018, Torque 2, Angulation -22 10 In distribution
164-1007 Slot size 022, Torque 15, Angulation -7, Rotation 6 10 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Leone SPA Leone SPA 2,306
BioQuick® Forestadent Bernhard Förster GmbH 1,842
Mini Master Series American Orthodontics 1,505
Mini-Mono® Forestadent Bernhard Förster GmbH 1,225
LP Low Profile American Orthodontics 1,204
Mini Sprint® Forestadent Bernhard Förster GmbH 1,193
Empower Bracket American Orthodontics 1,175
Legend GC Orthodontics America Inc. 1,098
Master Series American Orthodontics 1,084
Experience® GC Orthodontics America Inc. 770
The Orthodontic Store Young Innovations Inc. 658
equilibrium® Dentaurum GmbH & Co. KG 646

Showing 12 of 876. All products under Bracket, Metal, Orthodontic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K922806 1993-10-20
K923405 1993-05-05
K914616 1991-11-20
K900184 1990-04-02
K894358 1989-09-15
K894781 1989-09-15
K892704 1989-06-12
K870536 1987-02-19

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2009-02-13 Not classified Process control The recall was initiated because Ormco has confirmed that manufacturing error resulted in the Orthos CM Brackets being incorrectly manufactured with a torque of -9. The packaging was labeled with +9 torque; however the brackets contained in 304 units 2012-03-02
2004-11-18 Not classified Other Misassembly. Stainless steel and titanium parts were mistakenly welded together to construct the device. The weld failed. 6,257 2005-06-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer