Bronchoscope (Flexible or Rigid)

Vision Probe Adapter and Suction Adapter

Registry build 21.09.26
21manufacturers in China registered for this device type
20catalogue numbers in this listing
11510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Guangdong (7), Zhejiang (5), Jiangsu (4). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code EOQ
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
Guangdong MacroLux Medical Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 9
Ningbo Wise Optomech Technology Corporation Ningbo Zhejiang Contract manufacturer 4
Hangzhou Broncus Medical Co., Ltd. Hangzhou Zhejiang Contract manufacturer 1
Tianjin Puli Ark Medical Technology Co., Ltd. Dongli District Tianjin Contract manufacturer 1
Micro-Tech (Nanjing) Co., Ltd. Nan Jing Jiangsu Contract manufacturer 49
Zhejiang Huanyi Sterilization Technology Co., Ltd. Huzhou Zhejiang Contract manufacturer 25
Shenzhen Hugemed Medical Technical Development Co., Ltd. Shenzhen Guangdong Manufacturer 22
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Suzhou Virgil Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Scivita Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 19
Anrei Medical (Hangzhou) Co., Ltd. Hangzhou Zhejiang Manufacturer 12

Showing 12 of 21. All 21 manufacturers in China registered for Bronchoscope (Flexible Or Rigid)

Record

Regulatory record for Bronchoscope (Flexible Or Rigid)
Listed by Intuitive Surgical, Inc., United States
FDA product code EOQ
Device type Bronchoscope (Flexible Or Rigid)
Device class Class 2
Regulation 21 CFR 874.4680
Establishment Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2025-10-23
Record revised 2026-07-22 (version 25)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date
Packaging Box of 5, box of 10, case of 8, case of 9, case of 90, case of 40
Distribution end date 2020-08-26

Catalogue Numbers

Catalogue numbers for Bronchoscope (Flexible Or Rigid)
Catalogue number Size Per pack Status
490207 In distribution
490108 In distribution
490113 In distribution
490110 In distribution
490107 In distribution
490101 In distribution
490213 In distribution
490024 In distribution
490117 In distribution
490116 In distribution
490114 In distribution
490115 2 In distribution
490115 In distribution
490124 In distribution
490111 In distribution
490118 In distribution
490025 In distribution
490112 In distribution
490101 Withdrawn
490108 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Bronchoscope (Flexible Or Rigid) Karl Storz GmbH & Co. KG 248
Pentax Hoya Corporation 39
Biopsy Forceps Olympus Medical Systems Corp. 31
Single-Use flexible Video Bronchoscope Hunan Vathin Medical Instrument Co., Ltd. 27
Pilling Teleflex Medical LLC 24
Silicone cap Efer Endoscopy 22
Endoso Hunan Endoso Life Technology Co., Ltd. 20
Exalt ™ Boston Scientific Corporation 17
Grasping Forceps Olympus Medical Systems Corp. 16
LungVision Tool Body Vision Medical Ltd 16
Fujifilm Fujifilm Corporation 15
LoopView® Macrolux Medical Technology Co., Ltd. 15

Showing 12 of 255. All products under Bronchoscope (Flexible Or Rigid)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252045 2025-09-23
K252528 2025-09-05
K242070 2024-09-24
K240135 2024-04-03
K232984 2023-12-18
K220299 2022-06-16
K212048 2021-08-26
K202370 2020-11-16
K201146 2020-06-26
K192367 2019-11-26
K182188 2019-02-14

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-12-04 Class II Process control Due to probe bags that may have a compromised or incomplete sterile pouch seal. 110580
2024-07-12 Class II Under Investigation by firm There is a potential that the robotic system’s instrument cart arm may contain screws that may potentially fail which could result in uncontrolled motion of a catheter inside a patient’s airways. 3 units
2021-08-06 Class II Under Investigation by firm Potential for the sheath tip on the biopsy needle to separate from the sheath shaft. 1625 units 2024-05-17
2020-10-23 Class II Device Design The distal tip ring of the fully articulating catheter may become dislodged during the procedure. 454 catheters 2022-12-05
2020-06-10 Class II Device Design One type of the ION Catheter Reprocessing Covers (PN 490114-02) has the potential to become disengaged or incorrectly engaged to the ION Fully Articulating Catheter which can result in retention of cleaning chemical or water during reproces 67 units
2020-06-10 Class II Device Design One type of the ION Catheter Reprocessing Covers (PN 490114-02) has the potential to become disengaged or incorrectly engaged to the ION Fully Articulating Catheter which can result in retention of cleaning chemical or water during reproces 27 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer