Rigid Scopes

Ridid Endoscope,sterrad NX Co

Registry build 21.09.26
1manufacturer
3catalogue numbers in this listing
2recalls on this code

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code EQL
Manufacturer City Province Registered as Device types
Shenzhen Heearly Technology Co., Ltd. Bao An District, Shenzhen Guangdong Contract manufacturer 13

Record

Regulatory record for Rigid Scopes
Listed by Pentax of America, Inc., United States
FDA product code EQL
Device type Laryngostroboscope
Device class Class 1
Regulation 21 CFR 874.4750
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K921285
Record published 2018-02-26
Record revised 2023-11-17 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Liquid Chemical, Ethylene Oxide, High-level Disinfectant
Prescription Prescription only
Label carries serial number
Sizes Angle 70 °; outer diameter 6 to 9.5 mm

Catalogue Numbers

Catalogue numbers for Rigid Scopes
Catalogue number Size Status
9108 Angle 70.0 ° In distribution
9106 Angle 70.0 ° In distribution
9109 Angle 70.0 ° In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Jedmed Jedmed Instrument Company 62
Laryngostroboscope Pentax of America, Inc. 22
Laryngostroboscope Karl Storz GmbH & Co. KG 7
Video Laryngostroboscope Pentax of America, Inc. 3
Olympus Olympus Winter & IBE Gmbh 3
Pulsar Karl Storz GmbH & Co. KG 2
Atmos Atmos Medizintechnik Gmbh & Co. KG 2
Optomic Optomic España SA 2
Pentax Medical Rigid Laryngostroboscopes Pentax of America, Inc. 1
Pentax Medical Laryngeal Stroboscope Pentax of America, Inc. 1
Machida Machida Endoscope Co., Ltd. 1
Laryngostroboscope National Advanced Endoscopy Devices, Inc. 1

Showing 12 of 14. All products under Laryngostroboscope

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-12-12 Class II Labeling design Pentax is initiating a Field Correction to revise the Instructions for Use of the Rigid Laryngostroboscopes Model 9106 and 9108. 2,056 (1,545 (US) and 511 (OUS)) 2019-03-22
2016-04-06 Class II Device Design Pentax has become aware that operational/cleaning accessories and therapeutic devices (e.g., clips, stents, balloons, etc.) can become lodged in an endoscope’s instrument channel. 206 units 2017-12-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.