The Relieva Ultirra Nav is a sinus balloon catheter used to dilate sinus openings and spaces during diagnostic and therapeutic procedures. In adults it is intended for maxillary, frontal…
The Relieva Ultirra Nav is a sinus balloon catheter used to dilate sinus openings and spaces during diagnostic and therapeutic procedures. In adults it is intended for maxillary, frontal and sphenoid sinuses; in patients aged 17 or younger, use is limited to the maxillary sinus.
The flexible shaft carries a noncompliant balloon measuring 5 mm in diameter and 16 mm in length. Inflation with sterile saline or water mechanically dilates the target opening, while the shaft allows passage of a compatible navigation guidewire or sinus illumination system.
Listed Item
RELIEVA ULTIRRA NAV SINUS BALLOON CATHETER, 5x16MM
Navigation Compatibility
The catheter can be used with the Acclarent NavWire and CARTO ENT system to assist access and confirm placement. It is supplied after ethylene oxide sterilization for single-patient use.
Who Else Makes It
Concentrated in Guangdong (4), Jiangsu (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Forefront Medical Technology (Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 14 |
| Shenzhen Insighters Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Elite Medtek(Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 9 |
| Shanghai Medical Instruments (Group) Ltd. Corp. | Shanghai | Shanghai | Contract manufacturer | 235 |
| Xinhua Surgical Instrument Co., Ltd. | Zibo | Shandong | Manufacturer | 222 |
| Hangzhou Kangji Medical Instrument Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Modern Medical Equipment Manufacturing (Qing Yuan) Ltd | Qing Yuan | Guangdong | Contract manufacturer | 26 |
| Shenzhen Hugemed Medical Technical Development Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 22 |
| Hangzhou Endo Medical Instrument Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 19 |
| Jiangsu Yongle Medical Technology Co., Ltd. | Taixing | Jiangsu | Manufacturer | 4 |
Record
| Listed by | Acclarent, Inc., United States |
|---|---|
| FDA product code | LRC |
| Device type | Instrument, Ent Manual Surgical |
| Device class | Class 1 |
| Regulation | 21 CFR 874.4420 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K161698 |
| Record published | 2017-08-01 |
| Record revised | 2026-01-12 (version 9) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Store in a cool, dry place |
| Packaging | Box of 5 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| BC0516RUN | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Instrument, Ent Manual Surgical | Karl Storz GmbH & Co. KG | 2,062 |
| Fentex | Fentex medical GmbH | 1,738 |
| Elmed | Elmed, Inc. | 504 |
| RZ Medizintechnik GmbH | RZ Medizintechnik Gmbh | 441 |
| Evonos | Gyrus Acmi, Inc. | 291 |
| Millennium | Avalign Technologies, Inc. | 283 |
| Elmed Incorporated | Elmed, Inc. | 277 |
| Instrument, Ent Manual Surgical | Stryker Leibinger Gmbh & Co. KG | 169 |
| Rhinoforce | Karl Storz GmbH & Co. KG | 112 |
| Surtex | Surtex Instruments Ltd | 85 |
| Kerrison sphenoid punch | Spiggle & Theis Medizintechnik Gmbh | 82 |
| Gyrus Acmi | Gyrus Acmi, Inc. | 78 |
Showing 12 of 661. All products under Instrument, Ent Manual Surgical
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K201115 | 2020-08-27 |
| K190525 | 2019-05-03 |
| K171687 | 2017-09-05 |
| K161698 | 2016-10-24 |
| K153341 | 2016-02-12 |
| K143541 | 2015-04-22 |
| K150172 | 2015-04-07 |
| K140160 | 2014-02-20 |
| K120280 | 2012-11-05 |
| K111875 | 2011-10-11 |
| K111254 | 2011-08-22 |
| K061903 | 2006-08-18 |
| K052198 | 2005-08-31 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2006-01-20 | Not classified | Other | Device sterility may be compromised as evidenced by a loss of package integrity. | 149 units | 2006-05-11 |