Emano Flow
Emano Flow is a prescription-use smartphone software application that analyzes audio recordings of urination to measure urinary flow rate and voided volume in male patients with lower…
Emano Flow is a prescription-use smartphone software application that analyzes audio recordings of urination to measure urinary flow rate and voided volume in male patients with lower urinary tract symptoms.
Who Else Makes It
Concentrated in Jiangsu (2), Guangdong (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Primecare Medical (Suzhou) Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 20 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
| Hangzhou Primecare Medical Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Amsino Medical (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 22 |
| Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 4 |
| Qingdao Unison Industries Co., Limited | Shandong | Shandong | Specification developer | 3 |
Record
| Listed by | Emano Metrics, Inc., United States |
|---|---|
| FDA product code | EXY |
| Device type | Uroflowmeter |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1800 |
| Establishment | Manufacturer |
| Premarket notification | Exempt |
| Record published | 2026-06-16 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Emano Flow | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| CarePath | Cleartrac Technologies, LLC | 5 |
| Fize kUO Console | Fize Research Ltd | 5 |
| Urocap IV Light | Laborie Medical Technologies, Canada ULC | 4 |
| proudP | Soundable Health, Inc. | 2 |
| Fize kUO Disposable Kit | Fize Research Ltd | 2 |
| Urocap III | Laborie Medical Technologies, Canada ULC | 2 |
| Stream Dx | Zien Medical Technologies LLC | 2 |
| Rivus | Neurosoft, OOO | 2 |
| Fize kUO Disposable kit Pediatrics | Fize Research Ltd | 2 |
| EasyFlo Console | Srs Medical Systems, Inc. | 1 |
| EasyFlo Scale | Srs Medical Systems, Inc. | 1 |
| WiFLOW | Prometheus Group OF NEW Hampshire Limited, THE | 1 |
Showing 12 of 30. All products under Uroflowmeter
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-05-29 | Class II | Software Design Change | Problem description/Reason for recall: During the period March 22, 2026, to May 29, 2026, recorded urination audio was captured at 48,000 Hz while the model was trained and validated on 44,100 Hz audio. The models depend on the sampling so | 685 |