Hobbs Posi-Stop Injection Needle
A flexible, sterile, sharp bevel-edged, hollow tubular device intended to be manually-operated through a compatible endoscope to perform various needle functions (e.g., injection,…
A flexible, sterile, sharp bevel-edged, hollow tubular device intended to be manually-operated through a compatible endoscope to perform various needle functions (e.g., injection, aspiration, irrigation, puncture) during endoscopy. It is designed with appropriate shape, materials, gauge, and other characteristics (e.g., high-contrast tips) to function through the working channel of an endoscope. This is a single-use device.
Who Else Makes It
Concentrated in Zhejiang (10), Jiangsu (8), Shanghai (4). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Jiuhong Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
| Beijing Zksk Technology Co., Ltd. | Beijing | Beijing | Contract manufacturer | 38 |
| Rozer Sterilization Technology Shuyang Company Limited | Shuyang | Jiangsu | Contract manufacturer | 33 |
| Zhejiang Chuangxiang Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Zhejiang Huanyi Sterilization Technology Co., Ltd. | Huzhou | Zhejiang | Contract manufacturer | 25 |
| Yangzhou Fartley Medical Instrument Technology Co., Ltd. | Yangzhou | Jiangsu | Contract manufacturer | 24 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Jiana Sterilization Technology (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 23 |
| Promisemed Hangzhou Meditech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 21 |
Showing 12 of 23. All 23 manufacturers in China registered for Endoscopic Injection Needle, Gastroenterology-Urology
Record
| Listed by | Hobbs Medical, Inc., United States |
|---|---|
| FDA product code | FBK |
| Device type | Endoscopic Injection Needle, Gastroenterology-Urology |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1500 |
| Establishment | Contract manufacturer, Contract steriliser, Repacker / relabeller, Manufacturer |
| 510(k) | K834403 |
| Record published | 2016-09-21 |
| Record revised | 2025-11-24 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Distribution end date | 2025-11-21 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 4714 | In distribution | |
| 4723 | In distribution | |
| 4712 | In distribution | |
| 4708 | In distribution | |
| 4702 | In distribution | |
| 4718 | In distribution | |
| 4722 | In distribution | |
| 4714S | In distribution | |
| 4716 | In distribution | |
| 4706 | In distribution | |
| 4720 | In distribution | |
| 4704 | In distribution | |
| 4721 | In distribution | |
| 4712S | Withdrawn | |
| 4720S | Withdrawn | |
| 4712S-01 | Withdrawn | |
| 4714S-01 | Withdrawn | |
| 4718S | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Sclerotherapy needle | Zhejiang Chuangxiang Medical Technology Co., Ltd. | 248 |
| Disposable Injection Needles | Ningbo Xinwell Medical Technology Co., Ltd. | 150 |
| Single Use Injector | Olympus Medical Systems Corp. | 91 |
| Endoscopic Injection Needle, Gastroenterology-Urology | Hangzhou AGS MedTech Co., Ltd. | 90 |
| Zksk | Beijing Zksk Technology Co., Ltd. | 90 |
| Single Use Injector NM600/610 | Olympus Medical Systems Corp. | 62 |
| Disposable Injector NM | Olympus Medical Systems Corp. | 46 |
| Injection Needle | Micro-Tech (Nanjing) Co., Ltd. | 33 |
| Cook | Cook Incorporated | 25 |
| Injectra, Sclero Tip | Medi-Globe Gmbh | 14 |
| MT | Micro-Tech (Nanjing) Co., Ltd. | 12 |
| Alton | Alton Shanghai Medical Instruments Co Ltd | 12 |
Showing 12 of 58. All products under Endoscopic Injection Needle, Gastroenterology-Urology
Recalls Naming This Product
15 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 70 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 45 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 6 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 5 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 15 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 6 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 12 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 198 units |
| Hobbs Medical, Inc. | 510(k) number | 2024-10-04 | Class II | Process change control | Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle. | 10 units |
| Hobbs Medical, Inc. | 510(k) number | 2022-07-29 | Class II | Process control | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot | 8 units |
| Hobbs Medical, Inc. | 510(k) number | 2022-07-29 | Class II | Process control | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot | 7 units |
| Hobbs Medical, Inc. | UDI-DI | 2022-07-29 | Class II | Process control | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot | 6 units |
| Hobbs Medical, Inc. | UDI-DI | 2022-07-29 | Class II | Process control | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot | 30 units |
| Hobbs Medical, Inc. | UDI-DI | 2022-07-29 | Class II | Process control | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot | 50 units |
| Hobbs Medical, Inc. | UDI-DI | 2022-07-29 | Class II | Process control | Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9/28/2020, expiration dates between 2022-11-01 and 2025-09-01 (Devices have a lot | 17 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.