Biopty-CUT

BIOPTY-CUT® Disposable Core Biopsy Needle with Spacer, 14g x 20cm

Registry build 21.09.26
3manufacturers in China registered for this device type
10catalogue numbers in this listing
8recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Zhejiang (1).

Chinese manufacturers registered for FDA product code FCG
Manufacturer City Province Registered as Device types
Micro-Tech (Nanjing) Co., Ltd. Nan Jing Jiangsu Contract manufacturer 49
Promisemed Hangzhou Meditech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 21
Suzhou Leapmed Healthcare Corporation Suzhou Jiangsu Contract manufacturer 3

Record

Regulatory record for Biopty-CUT
Listed by Bard Peripheral Vascular, Inc., United States
FDA product code FCG
Device type Biopsy Needle
Device class Class 2
Regulation 21 CFR 876.1075
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2016-09-13
Record revised 2024-08-28 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Case of 10
Sizes Needle gauge 14 to 20 G; length 10 to 20 cm
Distribution end date 2023-03-06

Catalogue Numbers

Catalogue numbers for Biopty-CUT
Catalogue number Size Status
441610 Needle Gauge 16 G Withdrawn
451420 Length 20 cm Withdrawn
451816 Needle Gauge 18 G Withdrawn
451410 Needle Gauge 14 G Withdrawn
452020 Needle Gauge 20 G Withdrawn
441416 Length 16 cm Withdrawn
441410 Length 10 cm Withdrawn
452016 Needle Gauge 20 G Withdrawn
141410 Length 10 cm Withdrawn
441816 Length 16 cm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Biopsybell Biopsybell SRL 227
Biopsybell SRL Biopsybell SRL 130
Medline Industries, Inc. Medline Industries, Inc. 98
Themy M.D.L. S.R.L. 61
SemiCut M.D.L. S.R.L. 46
Temno® Merit Medical Systems, Inc. 37
Temno Carefusion 2200, Inc. 36
CorVocet™ Merit Medical Systems, Inc. 34
Truguide Bard Peripheral Vascular, Inc. 31
Temno Evolution® Merit Medical Systems, Inc. 28
ClearTip Finemedix 25
Magnum Bard Peripheral Vascular, Inc. 22

Showing 12 of 115. All products under Biopsy Needle

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-08-02 Class II Packaging change control Due to possible packaging damage (indentations/cuts) cause by manufacturing process. As a result of the packaging damage, may cause the sterile barrier to be compromised. 60 (U.S.) and 5,160 (O.U.S.)
2016-07-06 Class II Packaging May contain two trocar tip stylets with coaxials or two blunt tip stylets instead of one of each. 1250 units 2016-11-17
2016-02-04 Class II Unknown/Undetermined by firm Bard Peripheral Vascular, Inc. is recalling Bard TruGuide Disposable Coaxial Biopsy Needles because they have the potential to have the incorrect sized blunt tip stylet within its packaging that will not pass through the coaxial. 2320 units 2016-08-03
2009-10-08 Not classified Process design The recall was initiated after the firm determined that some Magnum Disposable Biopsy Core Needle 16 gauge lots may exhibit an exposed sample chamber, due to extended stylet length resulting from a loose hub connection. The exposed sample c 127,169 units 2012-04-02
2009-10-08 Not classified Process design The recall was initiated after the firm determined that some Magnum Disposable Biopsy Core Needle 16 gauge lots may exhibit an exposed sample chamber, due to extended stylet length resulting from a loose hub connection. The exposed sample c 77, 848 units 2012-04-02
2009-10-08 Not classified Process design The recall was initiated after the firm determined that some Magnum Disposable Biopsy Core Needle 16 gauge lots may exhibit an exposed sample chamber, due to extended stylet length resulting from a loose hub connection. The exposed sample c 32, 427 units 2012-04-02
2009-10-08 Not classified Process design The recall was initiated after the firm determined that some Magnum Disposable Biopsy Core Needle 16 gauge lots may exhibit an exposed sample chamber, due to extended stylet length resulting from a loose hub connection. The exposed sample c 97, 257 units 2012-04-02
2006-05-01 Not classified Other Manufacturing change that has introduced variability in the length of the inner stylet. When the inner stylet length is inserted into the cannula component, the exposed stylet length may be up to 8mm longer than expected. 225 2012-04-24

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer