Zksk
48 catalogue numbers from BF18-F23/230-J, listed by Beijing Zksk Technology Co., Ltd., China, under Forceps, Biopsy, Non-Electric. 44 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (18), Zhejiang (14), Shanghai (4). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Beijing Zksk Technology Co., Ltd. | Beijing | Beijing | Contract manufacturer | 38 |
| Zhejiang Chuangxiang Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Yangzhou Fartley Medical Instrument Technology Co., Ltd. | Yangzhou | Jiangsu | Contract manufacturer | 24 |
| Jiangsu Grit Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 13 |
| Changzhou Jiuhong Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Guangdong MacroLux Medical Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 9 |
| Jiangsu Power-Endo Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 7 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Xinhua Surgical Instrument Co., Ltd. | Zibo | Shandong | Manufacturer | 222 |
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
| Rozer Sterilization Technology Shuyang Company Limited | Shuyang | Jiangsu | Contract manufacturer | 33 |
Showing 12 of 44. All 44 manufacturers in China registered for Forceps, Biopsy, Non-Electric
Record
| Listed by | Beijing Zksk Technology Co., Ltd., China |
|---|---|
| FDA product code | FCL |
| Device type | Forceps, Biopsy, Non-Electric |
| Device class | Class 1 |
| Regulation | 21 CFR 876.1075 |
| Establishment | Contract manufacturer, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2024-04-12 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| BF18-F23/230-J | In distribution | |
| BF18-G23/180P | In distribution | |
| BF18-H23/230P | In distribution | |
| BF18-A23/230P | In distribution | |
| BF18-F23/50P-J | In distribution | |
| BF18-A23/50P | In distribution | |
| BF18-D23/230P | In distribution | |
| BF18-F18/50P-J | In distribution | |
| BF18-F18/230P-J | In distribution | |
| BF18-F18/50-J | In distribution | |
| BF18-A18/120 | In distribution | |
| BF18-F23/120P-J | In distribution | |
| BF18-F23/230P | In distribution | |
| BF18-F18/180P-J | In distribution | |
| BF18-F18/160P-J | In distribution | |
| BF18-F18/120P-J | In distribution | |
| BF18-E23/230P | In distribution | |
| BF18-F23/160P-J | In distribution | |
| BF18-F23/230P-J | In distribution | |
| BF18-A23/160 | In distribution | |
| BF18-F18/230-J | In distribution | |
| BF18-A23/160P | In distribution | |
| BF18-F23/120-J | In distribution | |
| BF18-A18/160P | In distribution | |
| BF18-A18/50P | In distribution | |
| BF18-A18/230 | In distribution | |
| BF18-A18/230P | In distribution | |
| BF18-A18/180P | In distribution | |
| BF18-A23/120 | In distribution | |
| BF18-F23/50-J | In distribution | |
| BF18-A18/180 | In distribution | |
| BF18-A23/180 | In distribution | |
| BF18-F23/180-J | In distribution | |
| BF18-G23/160P | In distribution | |
| BF18-F18/160-J | In distribution | |
| BF18-A23/230 | In distribution | |
| BF18-F23/180P-J | In distribution | |
| BF18-A23/180P | In distribution | |
| BF18-F23/160-J | In distribution | |
| BF18-B18/120P | In distribution | |
| BF18-A23/50 | In distribution | |
| BF18-F18/180-J | In distribution | |
| BF18-F18/120-J | In distribution | |
| BF18-A18/50 | In distribution | |
| BF18-A18/160 | In distribution | |
| BF18-A18/120P | In distribution | |
| BF18-A23/120P | In distribution | |
| BF18-C23/50P | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Forceps, Biopsy, Non-Electric | Hangzhou AGS MedTech Co., Ltd. | 384 |
| Disposable Endoscopic Biopsy Forceps | Ningbo Xinwell Medical Technology Co., Ltd. | 384 |
| Single Use Biopsy Forceps | Zhejiang Chuangxiang Medical Technology Co., Ltd. | 224 |
| Surgical Direct | Surgical Direct, Inc. | 153 |
| Surtex | Surtex Instruments Ltd | 129 |
| Single-Use Biopsy Forceps | Micro-Tech (Nanjing) Co., Ltd. | 81 |
| Disposable Biopsy Forceps | Olympus Medical Systems Corp. | 60 |
| Optimos™ Biopsy Forceps | Taewoongmedical.co., Ltd. | 28 |
| Forceps, Biopsy, Non-Electric | Richard Wolf Gmbh | 28 |
| Biopsy Forceps | Taewoongmedical.co., Ltd. | 28 |
| MT | Micro-Tech (Nanjing) Co., Ltd. | 26 |
| MSI Precision Specialty Instruments | MED Saver, Inc. | 25 |
Showing 12 of 117. All products under Forceps, Biopsy, Non-Electric
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.