High Flow Insufflation Unit
"UHI-4 45L Highflow Insufflation Unit"
5manufacturers in China registered for this device type
2catalogue numbers in this listing
1510(k) clearance
Who Else Makes It
Concentrated in Jiangsu (3), Zhejiang (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Smartdata Suzhou Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 11 |
| Zhejiang Chuangxiang Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Jiana Sterilization Technology (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 23 |
| Changzhou Intl. Trade & Enterprises Cooperative Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 14 |
| Changzhou Endoclean Medical Device Co., Ltd. | Changzhou | Jiangsu | Repacker / relabeller | 13 |
Record
| Listed by | Olympus Medical Systems Corp., Japan |
|---|---|
| FDA product code | FCX |
| Device type | Insufflator, Automatic Carbon-Dioxide For Endoscope |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1500 |
| Establishment | Specification developer, Manufacturer, Exporter |
| 510(k) | K243527 |
| Record published | 2025-02-27 |
| Record revised | 2025-10-06 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| UHI-4 | In distribution | |
| UHI-4 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Insufflator, Automatic Carbon-Dioxide For Endoscope | Us Endoscopy | 15 |
| Fujifilm | Fujifilm Corporation | 5 |
| Irrigator/Insufflator | Pentax of America, Inc. | 5 |
| DIN 477 High Pressure Hose for CO2 | Bracco Diagnostics, Inc. | 3 |
| East Coast Surgical Instruments | East Coast Surgical Inc. | 3 |
| Insufflator, Automatic Carbon-Dioxide For Endoscope | Richard Wolf Gmbh | 3 |
| CO2MPACT | Us Endoscopy | 3 |
| Endoscopic CO2 Regulation Unit | Olympus Medical Systems Corp. | 3 |
| Protocol Touch Colon Insufflator | Bracco Diagnostics, Inc. | 3 |
| Protocol Accessory Cart | Bracco Diagnostics, Inc. | 2 |
| High Pressure Hose and Yoke | Bracco Diagnostics, Inc. | 2 |
| Cylinder Hose | Olympus Medical Systems Corp. | 2 |
Showing 12 of 38. All products under Insufflator, Automatic Carbon-Dioxide For Endoscope
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K063786 | 2007-03-05 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Olympus Corporation of the Americas | 510(k) number | 2026-06-16 | Class II | Nonconforming Material/Component | Potential for unexpected instances where the front panel display turns off unexpectedly, and air delivery (insufflation) ceases. | 3,087 units |
| Olympus Corporation of the Americas | UDI-DI | 2023-09-25 | Class II | Process control | Olympus has become aware of an increased trend of both repairs and customer complaints reporting “UHI-4 stopping air supply due to the front panel LED turning off”. | 3,172 Units |
| Olympus Corporation of the Americas | UDI-DI | 2023-09-22 | Class I | Under Investigation by firm | There have been reports of patients suffering arrhythmias, reported as short cardiac arrests, during surgical procedures where UHI-4s were used. These events may have been due to an over insufflation of the abdominal cavity resulting from | 3136 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.