Trokamed
for 18 Fr. sheath, 390 mm
Who Else Makes It
Concentrated in Guangdong (10), Shanghai (4), Zhejiang (3). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Guangdong MacroLux Medical Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 9 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Zhejiang Chuangxiang Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Jiana Sterilization Technology (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 23 |
| Shenzhen Hugemed Medical Technical Development Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 22 |
| Macrolux Medical Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 9 |
| Zhuhai Pusen Medical Technology Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 7 |
| Seplou (Zhuhai) Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 7 |
| Zhejiang Yigao Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 7 |
| Eternal (Shanghai) Medical Technology Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 7 |
Showing 12 of 19. All 19 manufacturers in China registered for Endoscopic Access Overtube, Gastroenterology-Urology
Record
| Listed by | Trokamed Gmbh, Germany |
|---|---|
| FDA product code | FED |
| Device type | Endoscopic Access Overtube, Gastroenterology-Urology |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1500 |
| Establishment | Contract manufacturer, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2023-07-10 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| WA2PS18L | In distribution | |
| WA2PD18A | In distribution | |
| WA2PS20S | In distribution | |
| WA2PS18S | In distribution | |
| WA2PS20L | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ClearPetra | Well Lead Medical Co., Ltd. | 175 |
| CoralWell | Macrolux Medical Technology Co., Ltd. | 56 |
| Single Use Ureteral Access Sheath | Zhejiang Chuangxiang Medical Technology Co., Ltd. | 35 |
| Single-use Ureteral Access Sheath | Shenzhen Hugemed Medical Technical Development Co., Ltd. | 25 |
| Flexor | Cook Incorporated | 25 |
| Seplou | Seplou (Zhuhai) Co., Ltd. | 24 |
| Flexor Parallel | Cook Incorporated | 21 |
| Single-use Ureteral Access Sheath | Hunan Vathin Medical Instrument Co., Ltd. | 20 |
| Ureteral Access Sheath | Well Lead Medical Co., Ltd. | 18 |
| Guardus | Us Endoscopy | 16 |
| Porges Coloplast | Coloplast A/S | 14 |
| Forté® AXP Access Sheath | Applied Medical Resources Corp. | 13 |
Showing 12 of 66. All products under Endoscopic Access Overtube, Gastroenterology-Urology
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K200770 | 2021-07-30 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Trokamed Gmbh | UDI-DI | 2024-11-27 | Class I | Labeling False and Misleading | If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure. | 34 units |
| Trokamed Gmbh | UDI-DI | 2024-11-27 | Class I | Labeling False and Misleading | If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure. | 42 units |
| Trokamed Gmbh | UDI-DI | 2024-11-27 | Class I | Labeling False and Misleading | If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure. | 53 units |
| Trokamed Gmbh | UDI-DI | 2024-11-27 | Class I | Labeling False and Misleading | If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure. | 102 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.