Olympus
13 catalogue numbers from MAJ-1682, listed by Keymed (Medical & Industrial Equipment) Ltd, United Kingdom, under Pump, Air, Non-Manual, For Endoscope. 4 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (2), Shanghai (1), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jiangsu JianYu Health Medical Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 35 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
Record
| Listed by | Keymed (Medical & Industrial Equipment) Ltd, United Kingdom |
|---|---|
| FDA product code | FEQ |
| Device type | Pump, Air, Non-Manual, For Endoscope |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1500 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2023-07-05 |
| Record revised | 2018-03-29 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Storage | Special storage condition: ROOM TEMPERATURE; Storage environment temperature -40 to 70 °C |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| MAJ-1682 | 10 | In distribution | |
| MAJ-1681 | 10 | In distribution | |
| MAJ-1608 | 50 | In distribution | |
| MAJ-1651 | 10 | In distribution | |
| MAJ-1607 | 10 | In distribution | |
| OFP-2 (ROW) | In distribution | ||
| MAJ-1608 | 10 | In distribution | |
| MAJ-1606 | 100 | In distribution | |
| MAJ-1607 | 50 | In distribution | |
| OFP-2 (US) | In distribution | ||
| MAJ-1603 | 3 | In distribution | |
| MAJ-1606 | 10 | In distribution | |
| MAJ-1652 | 100 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Erbe | Erbe Elektromedizin GmbH | 24 |
| AquaShield | Us Endoscopy | 16 |
| Hydra | Boston Scientific Corporation | 13 |
| Erbeflo CleverCap® | Erbe Medical, LLC | 8 |
| Olympus | Olympus Winter & IBE Gmbh | 7 |
| Erbeflo AeroRinse® | Erbe Medical, LLC | 4 |
| Endogator | Medivators Inc | 4 |
| Defendo | Medivators Inc | 3 |
| Torrent and AquaShield | Us Endoscopy | 2 |
| CS-05-00-290 OpClear Disposable | Cipher Surgical Ltd | 1 |
| CS-10-00-300 OpClear Disposable | Cipher Surgical Ltd | 1 |
| CS-10-00-315 OpClear Disposable | Cipher Surgical Ltd | 1 |
Showing 12 of 30. All products under Pump, Air, Non-Manual, For Endoscope
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K100899 | 2010-09-13 |
| K000948 | 2000-05-12 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Olympus Corporation of the Americas | UDI-DI | 2024-08-23 | Class II | Equipment maintenance | During product testing, Olympus identified an intermittent loss of function of the OFP-2 Flushing Pump caused by an internal component connection failure. | 445 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.