Dover
6 catalogue numbers from P4A, listed by Cardinal Health, United States, under Device, Urine Flow Rate Measuring, Non-Electrical, Disposable. 19 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (10), Zhejiang (5), Shanghai (3). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Co., Limited | Changshu | Jiangsu | Contract manufacturer | 48 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Anhui Careplus Medical Technology Co., Ltd. | Xuancheng | Anhui | Contract manufacturer | 6 |
| Jinhua Kangdeli Medical Appliances Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 5 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Zhejiang Lidesen Medical Instrument Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 100 |
| Anji Spenq Industrial Co., Ltd. | Huzhou | Zhejiang | Manufacturer | 85 |
| Ningbo Greetmed Medical Instruments Co., Ltd. | Ningbo | Zhejiang | Specification developer | 75 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Suzhou Texnet | Suzhou | Jiangsu | Contract manufacturer | 47 |
Showing 12 of 19. All 19 manufacturers in China registered for Device, Urine Flow Rate Measuring, Non-Electrical, Disposable
Record
| Listed by | Cardinal Health, United States |
|---|---|
| FDA product code | FFG |
| Device type | Device, Urine Flow Rate Measuring, Non-Electrical, Disposable |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1800 |
| Establishment | Contract manufacturer, Reprocessor, Contract steriliser, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2016-09-24 |
| Record revised | 2026-05-27 (version 10) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Over the counter | Yes |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 15 to 30 °C |
| Packaging | Case of 10, case of 300, pack_or_inner_pack of 30 |
| Sizes | Total volume 100 to 400 ml; catheter gauge 16 to 18 Fr |
| Distribution end date | 2025-12-31 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| P4A | Total Volume 400 ml | In distribution | |
| P4P16TS | Catheter Gauge 16 Fr | Withdrawn | |
| P4P16XTS | Catheter Gauge 16 Fr | Withdrawn | |
| 145500 | Total Volume 100 ml | 50 | Withdrawn |
| 145501 | Total Volume 100 ml | Withdrawn | |
| P4P18TS | Catheter Gauge 18 Fr | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Dover | Cardinal Health 200, LLC | 14 |
| Medline | Medline Industries, Inc. | 10 |
| AMSure® Urine Meter Drainage Bag | Amsino Medical Inc. | 2 |
| Bard® CritiCore® Collection Container | C.R. Bard, Inc. | 1 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.