Bravo

Bravo CF capsule delivery dev, 5-pk

Registry build 21.09.26
1manufacturer
9catalogue numbers in this listing
1510(k) clearance
2recalls on this code

Who Else Makes It

Registered in Chongqing.

Chinese manufacturers registered for FDA product code FFT
Manufacturer City Province Registered as Device types
Chongqing Jinshan Science & Technology (Group) Co., Ltd. Chongqing Chongqing Manufacturer 4

Record

Regulatory record for Bravo
Listed by Given Imaging Ltd., Israel
FDA product code FFT
Device type Electrode, Ph, Stomach
Device class Class 1
Regulation 21 CFR 876.1400
Establishment Manufacturer
Premarket notification Exempt
Record published 2018-08-29
Record revised 2024-11-15 (version 9)

Specifications

Specifications
MRI safety MR Unsafe
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Handling environment temperature 20 to 45 °C; Storage environment temperature 15 to 45 °C

Catalogue Numbers

Catalogue numbers for Bravo
Catalogue number Size Per pack Status
FGS-0313 In distribution
FGS-0634 In distribution
FGS-0516 5 In distribution
FGS-0635 5 In distribution
FGS-0312 5 In distribution
FGS-0450 In distribution
RFB-0450 In distribution
FGS-0636 In distribution
FGS-0593 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Diversatek Healthcare Diversatek Healthcare Inc 36
Versaflex Given Imaging Ltd. 35
Heidelberg pH Capsule System Heidelberg Medical Inc 7
Restech THE Reflux Company 6
alpHaONE Chongqing Jinshan Science & Technology (Group) Co., Ltd. 4
Electrode, Ph, Stomach Given Imaging Ltd. 3
Reflux Given Imaging Ltd. 2
2 channel pH antimony, 21 cm spacing, 6.4 Fr Medical Measurement Systems B.V. 1
2 channel pH antimony, 15 cm spacing, 6.4 Fr Medical Measurement Systems B.V. 1
2 channel pH antimony, 10 cm spacing, 6.4 Fr Medical Measurement Systems B.V. 1
1 channel pH antimony, 6.4 Fr Medical Measurement Systems B.V. 1
Digitrapper Given Imaging Ltd. 1

Showing 12 of 14. All products under Electrode, Ph, Stomach

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K102543 2010-12-01

Recalls Naming This Product

2 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Bravo
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Given Imaging Ltd. UDI-DI 2026-08-06 Not classified Nonconforming Material/Component Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruction of the airway, hemorrhage/blood loss/bleeding, laceration of the esophagus, a 127,416
Given Imaging Ltd. UDI-DI 2025-06-03 Class I Process control It has been determined that misapplied adhesive on the Bravo CF capsule delivery device may lead to its malfunction. Specifically, the misapplied adhesive may prevent the capsule from attaching to the patient’s esophagus or detaching from t 128,202 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer