E-Line

INTERNAL SHEATH RESECTOSCOPE 24FR color code yellow, SL 208mm, round, rotatable irrigation ring, slanted distal end, ceramic, continuous irrigation, compatible with outer sheath 8655074,…

Registry build 21.09.26

INTERNAL SHEATH RESECTOSCOPE 24FR color code yellow, SL 208mm, round, rotatable irrigation ring, slanted distal end, ceramic, continuous irrigation, compatible with outer sheath 8655074, and telescopes Ø 4mm, 12°/30°, with 2 flushing ports, quick-lock, reusable

1manufacturer
33catalogue numbers in this listing
1recall

Who Else Makes It

Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code FJL
Manufacturer City Province Registered as Device types
Peter’s Technology (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 9

Record

Regulatory record for E-Line
Listed by Richard Wolf Gmbh, Germany
FDA product code FJL
Device type Resectoscope
Device class Class 2
Regulation 21 CFR 876.1500
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
Record published 2016-09-26
Record revised 2025-02-03 (version 11)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Label carries lot or batch number, manufacturing date
Storage Storage environment humidity 10 to 90 % RH; Storage environment temperature -20 to 60 °C
Sizes Outer diameter 3.83333 to 9 mm
Distribution end date 2024-10-19
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for E-Line
Catalogue number Size Status
841511 Outer Diameter 7.33333333333 mm In distribution
865467 Outer Diameter 8 mm In distribution
89700261 In distribution
841512 Outer Diameter 8 mm In distribution
8668024 Outer Diameter 8 mm In distribution
841513 Outer Diameter 8.66666666666 mm In distribution
841503 Outer Diameter 8.66666666666 mm In distribution
841502 Outer Diameter 8 mm In distribution
86770145 Outer Diameter 3.83333333333 mm In distribution
865468 Outer Diameter 8.66666666666 mm In distribution
865412 Outer Diameter 8 mm In distribution
865418 Outer Diameter 8.66666666666 mm In distribution
866812 Outer Diameter 8 mm In distribution
86543842 Outer Diameter 8.66666666666 mm In distribution
86770147 Outer Diameter 3.83333333333 mm In distribution
865416 Outer Diameter 7.33333333333 mm In distribution
865417 Outer Diameter 8 mm In distribution
865413 Outer Diameter 8.66666666666 mm Withdrawn
8655144 Outer Diameter 7.5 mm Withdrawn
86633741 Outer Diameter 8 mm Withdrawn
86633841 Withdrawn
8663084 Outer Diameter 8.66666666666 mm Withdrawn
865419 Withdrawn
8663384 Withdrawn
8663074 Outer Diameter 8 mm Withdrawn
8655084 Outer Diameter 8 mm Withdrawn
8655134 Outer Diameter 8.5 mm Withdrawn
8663374 Outer Diameter 8 mm Withdrawn
8661074 Outer Diameter 8 mm Withdrawn
86543942 Withdrawn
8654185 Outer Diameter 8.66666666666 mm Withdrawn
8654175 Outer Diameter 8 mm Withdrawn
8655074 Outer Diameter 9 mm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Olympus Olympus Winter & IBE Gmbh 58
Ureterorenoscope Sopro-Comeg GmbH 28
AED National Advanced Endoscopy Devices, Inc. 24
Shark Richard Wolf Gmbh 21
Urology syringe Sopro-Comeg GmbH 15
Resectoscope Richard Wolf Gmbh 14
Resectoscope Karl Storz GmbH & Co. KG 11
Panoview Richard Wolf Gmbh 8
Urology Evacuator Sopro-Comeg GmbH 7
Piranha Richard Wolf Gmbh 6
Veloxion Aulea Medical, Inc. 6
Gimmi Gimmi Gmbh 5

Showing 12 of 18. All products under Resectoscope

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-06-25 Class II Under Investigation by firm Product labeled as Cutting Electrode may contain BIVAP electrode. 20 boxes 2024-01-05

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer