Lens

Service Replacement Lens Integrated System NON-Wifi Version

Registry build 21.09.26
46manufacturers in China registered for this device type
20catalogue numbers in this listing
15510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Guangdong (15), Jiangsu (13), Zhejiang (7). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GCJ
Manufacturer City Province Registered as Device types
Hangzhou Kangji Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 27
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Hangzhou Endo Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 19
Beilun Plastech Inc Ningbo Zhejiang Contract manufacturer 13
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
Qingdao O-MEC Medical Technology Co., Ltd. Qingdao Shandong Contract manufacturer 6
Shenzhen Jingxintai Houseware Co., Ltd. Shenzhen Guangdong Contract manufacturer 6
MediConcepts Technology (Shenzhen) Company Limited Shenzhen Guangdong Contract manufacturer 5
Qisda Electronics (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Barco (Suzhou) Healthcare Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 4
Jiangsu Bana Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 4
Comhuge Medical Wire AND Harness Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 2

Showing 12 of 46. All 46 manufacturers in China registered for Laparoscope, General & Plastic Surgery

Record

Regulatory record for Lens
Listed by Smith & Nephew, Inc., United States
FDA product code GCJ
Device type Laparoscope, General & Plastic Surgery
Device class Class 2
Regulation 21 CFR 876.1500
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K153606
Record published 2017-08-15
Record revised 2023-09-07 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Supplied as a kit Yes
Label carries serial number

Catalogue Numbers

Catalogue numbers for Lens
Catalogue number Size Status
72204725S In distribution
72204942 In distribution
72204900 In distribution
72204354S In distribution
72204899 In distribution
72204894 In distribution
72204685S In distribution
72204895 In distribution
72204904 In distribution
72204902 In distribution
72204898 In distribution
72204903 In distribution
72204893 In distribution
72204354 In distribution
72204897 In distribution
72204725 In distribution
72204685 In distribution
72203967S In distribution
72204901 In distribution
72204896 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Elmed Elmed, Inc. 3,796
Surgical Direct Surgical Direct, Inc. 2,319
Novo Surgical Novo Surgical, Inc. 1,320
Elmed Incorporated Elmed, Inc. 911
Laparoscope, General & Plastic Surgery Karl Storz GmbH & Co. KG 774
Snowden-Pencer Steris Corporation 693
Millennium Avalign Technologies, Inc. 683
Hermann Medizintechnik GmbH Hermann Medizintechnik Gmbh 615
Clickline Karl Storz GmbH & Co. KG 582
V. Mueller Carefusion 2200, Inc. 553
Grasping forceps Sopro-Comeg GmbH 462
Gimmi Gimmi Gmbh 387

Showing 12 of 1,584. All products under Laparoscope, General & Plastic Surgery

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K201198 2020-07-17
K153606 2016-06-02
K070266 2007-02-22
K060777 2006-04-13
K050209 2005-11-23
K032680 2003-09-26
K031379 2003-05-22
K023053 2002-10-03
K011944 2001-09-19
K010489 2001-04-10
K990414 1999-04-14
K980604 1998-05-19
K974592 1998-01-12
K972471 1997-10-24
K971850 1997-08-12

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2012-03-29 Not classified Nonconforming Material/Component May experience intermittent loss of video
due to a defective board component
239 units 2016-01-13
2011-09-23 Not classified Process design HD1200 camera heads may cause image issues 15 units 2016-02-16

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer