MiroCam Capusle Endoscope System

MiroCam Capsule Endoscope System images the small bowel lining in adults. The MC2000-B capsule captures images as it travels through the gastrointestinal tract, and an MR2000 receiver…

Registry build 21.09.26

MiroCam Capsule Endoscope System images the small bowel lining in adults. The MC2000-B capsule captures images as it travels through the gastrointestinal tract, and an MR2000 receiver stores them for later review by a gastroenterologist.

The capsule uses a CMOS image sensor and twelve white LEDs. Image data are carried by a weak electrical signal through body tissues and fluids to sensor pads on the abdomen. Cables connect the pads to the receiver worn by the patient.

Listed Item

Package System(MC2000-B Capsule and MR2000 Receiver)

Image Review

After the procedure, the receiver connects to a computer by USB to upload the images. MiroView software supports review of the recorded data for suspected small-bowel abnormalities.

1manufacturer
2catalogue numbers in this listing
8510(k) clearances naming this product code
1recall

Who Else Makes It

Registered in Hubei. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code NEZ
Manufacturer City Province Registered as Device types
Ankon Technologies Co., Ltd. Wuhan Hubei Contract manufacturer 2

Record

Regulatory record for MiroCam Capusle Endoscope System
Listed by IntroMedic Co., Ltd., South Korea
FDA product code NEZ
Device type System, Imaging, Gastrointestinal, Wireless, Capsule
Device class Class 2
Regulation 21 CFR 876.1300
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K170438
Record published 2018-02-12
Record revised 2020-08-07 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Label carries lot or batch number, expiry date
Packaging Large box, large box of 16

Catalogue Numbers

Catalogue numbers for MiroCam Capusle Endoscope System
Catalogue number Size Per pack Status
MC2000-B, MR2000 In distribution
MC2000-B 5 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pillcam Given Imaging Ltd. 65
Rapid Given Imaging Ltd. 21
MiroCam Capsule Endoscope System IntroMedic Co., Ltd. 15
PillCam Covidien LP 9
NaviCam Small Bowel Capsule Endoscopy System Ankon Technologies Co., Ltd. 5
System, Imaging, Gastrointestinal, Wireless, Capsule Given Imaging Ltd. 3
PillCam Genius Given Imaging Ltd. 3
AdvanCE Us Endoscopy 2
CapsoCam Plus CapsoVision, Inc. 2
CapsoRetrieve CapsoVision, Inc. 2
CapsoView CapsoVision, Inc. 1
NaviCam Data Recorder ANX Robotica Corp. 1

Showing 12 of 44. All products under System, Imaging, Gastrointestinal, Wireless, Capsule

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252617 2026-05-08
K180732 2018-11-08
K170438 2018-01-30
K143663 2015-03-17
K134005 2014-07-09
K140751 2014-06-30
K123428 2013-05-20
K111450 2012-05-18

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-02-15 Class II Device Design When a user switches on MR1100 Receiver, even though the battery was fully charged, the LED was displayed as orange color due to momentary drop of battery voltage. 82 2018-08-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer