Hysafe

SCISSORS INSERT WITH SHEATH 5FR WL 340MM micro scissors, single action, WL 340 mm, with irrigation connection, take-apart, reusable

Registry build 21.09.26
6manufacturers in China registered for this device type
22catalogue numbers in this listing

Who Else Makes It

Concentrated in Zhejiang (4), Jiangsu (2).

Chinese manufacturers registered for FDA product code OCZ
Manufacturer City Province Registered as Device types
Micro-Tech (Nanjing) Co., Ltd. Nan Jing Jiangsu Contract manufacturer 49
Zhejiang Chuangxiang Medical Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 27
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26
Wuxi Goals Medical Technology Co., Ltd. Yixing Jiangsu Contract manufacturer 24
Jiana Sterilization Technology (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 23
Anrei Medical (Hangzhou) Co., Ltd. Hangzhou Zhejiang Manufacturer 12

Record

Regulatory record for Hysafe
Listed by Richard Wolf Gmbh, Germany
FDA product code OCZ
Device type Endoscopic Grasping/Cutting Instrument, Non-Powered
Device class Class 2
Regulation 21 CFR 876.1500
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
Record published 2023-01-03
Record revised 2024-11-29 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Label carries lot or batch number, manufacturing date
Storage Storage environment humidity 10 to 90 % RH; Storage environment temperature -20 to 60 °C
Sizes Outer diameter 1.33333 to 4 mm; length 340 to 550 mm

Catalogue Numbers

Catalogue numbers for Hysafe
Catalogue number Size Status
86426818 Outer Diameter 1.66666666666 mm In distribution
89596808 Outer Diameter 1.66666666666 mm In distribution
89546808 In distribution
8083001 In distribution
89596218 Outer Diameter 1.66666666666 mm In distribution
89526008 Length 550 mm In distribution
89526218 Outer Diameter 1.66666666666 mm In distribution
89626008 Length 350 mm In distribution
89626028 Outer Diameter 3 mm In distribution
89526508 Outer Diameter 1.66666666666 mm In distribution
86426508 Outer Diameter 1.66666666666 mm In distribution
89626108 Outer Diameter 3.5 mm In distribution
89526118 Outer Diameter 1.33333333333 mm In distribution
86426318 Length 340 mm In distribution
86456508 Outer Diameter 2.33333333333 mm In distribution
89626048 Outer Diameter 4 mm In distribution
89626078 Outer Diameter 4 mm In distribution
86456008 Length 340 mm In distribution
86426008 Outer Diameter 3.5 mm In distribution
89626058 Outer Diameter 4 mm In distribution
89926408 Outer Diameter 2.33333333333 mm In distribution
89926308 Outer Diameter 2.33333333333 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Endoscopic Grasping/Cutting Instrument, Non-Powered Stryker GmbH 176
Single Use Grasping Forceps Zhejiang Chuangxiang Medical Technology Co., Ltd. 53
Endoscopic Grasping/Cutting Instrument, Non-Powered Karl Storz GmbH & Co. KG 42
Hobbs Medical Polypectomy Snare Hobbs Medical, Inc. 27
Endoscopic Grasping/Cutting Instrument, Non-Powered Richard Wolf Gmbh 24
Grasping Forceps Olympus Medical Systems Corp. 17
EndoTBasket Endo-Therapeutics, Inc. 13
Halyard Avanos Medical, Inc. 11
Hobbs Helical Retrieval Basket Hobbs Medical, Inc. 8
Grasping Forceps Micro-Tech (Nanjing) Co., Ltd. 6
Foreign Body Grasping Forceps Avanos Medical, Inc. 6
Cook Cook Incorporated 5

Showing 12 of 31. All products under Endoscopic Grasping/Cutting Instrument, Non-Powered

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer