NaviCam Xpress Stomach Capsule Endoscope System, NaviCam Xpress Stomach System
The NaviCam Xpress Stomach System Controller directs a magnetic capsule within the stomach during capsule endoscopy. It runs NaviCtrl software, allowing the operator to control capsule…
The NaviCam Xpress Stomach System Controller directs a magnetic capsule within the stomach during capsule endoscopy. It runs NaviCtrl software, allowing the operator to control capsule position while the capsule obtains stomach images.
The NaviEC-2000 controller integrates the console and a touchscreen. An anti-collision sensor detects potential contact with a person or object. Images are reviewed separately using ESView software on a computer or laptop.
Listed Item
Controller. The NaviCam Xpress Stomach System is a endoscopic capsule imaging system intended to obtain images of the stomach. It differs from passive capsule endoscopy systems in that it uses magnetic fields to allow the position of the capsule within the stomach to be controlled by an operator
System Compatibility and Patients
The controller is used as part of the NaviCam Xpress Stomach System with its ingestible capsule and data recorder. The system is intended for stomach visualization in adults aged 22 or older with a body mass index below 38, in clinics or hospitals, including emergency departments.
Who Else Makes It
Concentrated in Hubei (1), Shanghai (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Ankon Technologies Co., Ltd. | Wuhan | Hubei | Contract manufacturer | 2 |
| Ankon Medical Technologies (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 2 |
Record
| Listed by | ANX Robotica Corp., United States |
|---|---|
| FDA product code | QKZ |
| Device type | Magnetically Maneuvered Capsule Endoscopy System |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1310 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K203192 |
| Record published | 2023-01-05 |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Controller/ NaviEC-2000 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| NaviCam Capsule Endoscope System | ANX Robotica Corp. | 3 |
| NaviCam Stomach System | ANX Robotica Corp. | 1 |
| NaviCam Tether | ANX Robotica Corp. | 1 |
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K241934 | 2024-07-31 |
| K231960 | 2023-10-03 |
| K230694 | 2023-04-13 |
| K221608 | 2022-11-22 |
| K203192 | 2021-05-04 |
| DEN190037 | 2020-05-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.