Universa

Universa Firm Ureteral Stent and Positioner With Hydrophilic Coating and Monofilament Tether

Registry build 21.09.26
4manufacturers in China registered for this device type
384catalogue numbers in this listing
13510(k) clearances naming this product code
27recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Zhejiang (1), Guangdong (1).

Chinese manufacturers registered for FDA product code FAD
Manufacturer City Province Registered as Device types
Zhejiang Chuangxiang Medical Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 27
Alton Shanghai Medical Instruments Co Ltd Shanghai Shanghai Complaint-file establishment 20
BQ Plus Medical Co., Ltd. Songjiang Shanghai Contract manufacturer 13
Shenzhen Trious Medical Technology Co., Ltd. Shenzhen Guangdong Manufacturer 6

Record

Regulatory record for Universa
Listed by Cook Incorporated, United States
FDA product code FAD
Device type Stent, Ureteral
Device class Class 2
Regulation 21 CFR 876.4620
Establishment Contract manufacturer, Contract steriliser, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-10-24
Record revised 2019-05-17 (version 3)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: Store in dark, dry, cool place.

Catalogue Numbers

Catalogue numbers for Universa
Catalogue number Size Status
G49762 In distribution
G23480 In distribution
G49899 In distribution
G49915 In distribution
G49985 In distribution
G49919 In distribution
G49918 In distribution
G23433 In distribution
G49912 In distribution
G49943 In distribution
G23239 In distribution
G53722 In distribution
G53686 In distribution
G49939 In distribution
G49869 In distribution
G53717 In distribution
G49884 In distribution
G53728 In distribution
G23312 In distribution
G23363 In distribution
G23452 In distribution
G49921 In distribution
G49906 In distribution
G49970 In distribution
G49991 In distribution
G23327 In distribution
G49888 In distribution
G53701 In distribution
G53725 In distribution
G49877 In distribution
G23470 In distribution
G49904 In distribution
G23504 In distribution
G49952 In distribution
G23424 In distribution
G23405 In distribution
G23368 In distribution
G49903 In distribution
G23343 In distribution
G49993 In distribution
G23360 In distribution
G49988 In distribution
G53674 In distribution
G53708 In distribution
G23389 In distribution
G49944 In distribution
G49950 In distribution
G53714 In distribution
G49910 In distribution
G49895 In distribution
G23359 In distribution
G23448 In distribution
G49984 In distribution
G53719 In distribution
G23411 In distribution
G23418 In distribution
G49875 In distribution
G23491 In distribution
G49978 In distribution
G53737 In distribution
G23385 In distribution
G23476 In distribution
G53731 In distribution
G23354 In distribution
G49983 In distribution
G23357 In distribution
G49900 In distribution
G49870 In distribution
G23437 In distribution
G23400 In distribution
G23423 In distribution
G23401 In distribution
G23373 In distribution
G23372 In distribution
G49948 In distribution
G23441 In distribution
G23430 In distribution
G23442 In distribution
G23371 In distribution
G49982 In distribution
G23345 In distribution
G23328 In distribution
G53718 In distribution
G49949 In distribution
G23451 In distribution
G49938 In distribution
G23316 In distribution
G23331 In distribution
G49880 In distribution
G53735 In distribution
G53716 In distribution
G23407 In distribution
G49914 In distribution
G53677 In distribution
G49941 In distribution
G49979 In distribution
G49967 In distribution
G23475 In distribution
G23461 In distribution
G53698 In distribution
G23382 In distribution
G49868 In distribution
G23387 In distribution
G49937 In distribution
G49987 In distribution
G49934 In distribution
G23336 In distribution
G49867 In distribution
G53726 In distribution
G49953 In distribution
G23366 In distribution
G49873 In distribution
G49908 In distribution
G23459 In distribution
G23449 In distribution
G53675 In distribution
G23317 In distribution
G23406 In distribution
G23464 In distribution
G23472 In distribution
G49972 In distribution
G23458 In distribution
G23477 In distribution
G23377 In distribution
G49980 In distribution
G49951 In distribution
G23447 In distribution
G23339 In distribution
G23390 In distribution
G23434 In distribution
G49986 In distribution
G23315 In distribution
G23404 In distribution
G23374 In distribution
G49940 In distribution
G49892 In distribution
G23338 In distribution
G23241 In distribution
G49936 In distribution
G49879 In distribution
G49907 In distribution
G23398 In distribution
G49924 In distribution
G23399 In distribution
G49975 In distribution
G23362 In distribution
G23462 In distribution
G53705 In distribution
G53693 In distribution
G23508 In distribution
G49956 In distribution
G23420 In distribution
G23417 In distribution
G23500 In distribution
G23348 In distribution
G23347 In distribution
G49961 In distribution
G49902 In distribution
G23455 In distribution
G49971 In distribution
G23314 In distribution
G23465 In distribution
G53683 In distribution
G23468 In distribution
G49885 In distribution
G23351 In distribution
G53715 In distribution
G49911 In distribution
G49883 In distribution
G53678 In distribution
G23499 In distribution
G53724 In distribution
G53695 In distribution
G23432 In distribution
G23413 In distribution
G23483 In distribution
G49925 In distribution
G49935 In distribution
G23490 In distribution
G53700 In distribution
G49932 In distribution
G49962 In distribution
G49955 In distribution
G49874 In distribution
G23352 In distribution
G23460 In distribution
G53672 In distribution
G23482 In distribution
G53704 In distribution
G23412 In distribution
G23479 In distribution
G49863 In distribution
G49894 In distribution
G23240 In distribution
G53713 In distribution
G49901 In distribution
G23511 In distribution
G23487 In distribution
G49931 In distribution
G49992 In distribution
G23445 In distribution
G49960 In distribution
G49882 In distribution
G23429 In distribution
G23395 In distribution
G49876 In distribution
G23330 In distribution
G23344 In distribution
G23493 In distribution
G53687 In distribution
G53145 In distribution
G23381 In distribution
G53682 In distribution
G49981 In distribution
G23495 In distribution
G49896 In distribution
G53691 In distribution
G53706 In distribution
G23392 In distribution
G23440 In distribution
G49866 In distribution
G23486 In distribution
G49872 In distribution
G49964 In distribution
G23443 In distribution
G23361 In distribution
G23474 In distribution
G49945 In distribution
G23498 In distribution
G53680 In distribution
G23369 In distribution
G23496 In distribution
G53688 In distribution
G49974 In distribution
G23408 In distribution
G49923 In distribution
G23379 In distribution
G23388 In distribution
G49862 In distribution
G23313 In distribution
G53676 In distribution
G49969 In distribution
G23365 In distribution
G53721 In distribution
G23326 In distribution
G23503 In distribution
G53712 In distribution
G23332 In distribution
G23421 In distribution
G49909 In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Porges Coloplast Coloplast A/S 509
Polaris™ Ultra Boston Scientific Corporation 406
Percuflex™ Plus Boston Scientific Corporation 300
Polaris™ Loop Boston Scientific Corporation 232
ImaJin Coloplast A/S 219
Contour™ Boston Scientific Corporation 205
Percuflex™ Boston Scientific Corporation 152
Tecoflex Gyrus Acmi, Inc. 92
Vortek Coloplast A/S 92
Sof-Flex Cook Incorporated 60
Tria™ Firm Boston Scientific Corporation 58
Q Urological Persistent Aguamedicina Q Urological Corporation 44

Showing 12 of 131. All products under Stent, Ureteral

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K181971 2019-04-23
K180557 2018-11-23
K180216 2018-09-28
K180029 2018-09-21
K180053 2018-09-13
K171603 2018-04-16
K172017 2018-03-26
K170010 2017-08-28
K162109 2017-06-07
K162104 2017-04-24
K161236 2017-01-27
K160891 2016-06-24
K151051 2016-01-11

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-01-04 Class II Nonconforming Material/Component Manufactured with incorrect material, which may result in the stent being stiffer and potentially susceptible to degradation could potentially lead to breakage/fragmentation. 42 units 2021-09-16
2020-07-30 Class II Under Investigation by firm Universa Soft Ureteral Stent Sets were incorrectly placed in the outer boxes labeled as Universa Firm Ureteral Stent Set ;pouch label reflects the packaged product. 20 units 2021-11-04
2019-01-04 Class II Process control The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip. 13388 total 2020-05-29
2019-01-04 Class II Process control The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip. 13388 total 2020-05-29
2019-01-04 Class II Process control The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip. 13388 total 2020-05-29
2019-01-04 Class II Process control The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip. 13388 total 2020-05-29
2019-01-04 Class II Process control The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip. 13388 total 2020-05-29
2019-01-04 Class II Process control The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip. 13388 total 2020-05-29
2010-10-18 Not classified Packaging The firm received a customer complaint that a box labeled as Universa Firm Stents but the box actually contained Universa Soft Stents. The inner product label is correct but the outer box is wrong. 25 units 2011-07-27
2008-11-10 Not classified Labeling mix-ups “Soft” stents were placed in “firm” stent outer boxes. The soft stent is only to be left in the patient for 6 months, but the firm stent can be left in the patient for 12 months, so this error could result in the stent being left in the pa 23 2009-11-25
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2008-07-31 Not classified Process control The bond may break where the two materials meet, resulting in separation of the stent. 1739 of all products. 2009-11-27
2007-06-29 Not classified Other The radiographic band may detach from the stent and remain in the patient after removal of the stent. 75 2008-06-11
2006-03-01 Not classified Other Instructions for Use (IFU) booklet missing pages 5-12. Pages 5-8 in English; 9-12 in Danish, describe stent duration, patient preparation, assembly, implanting, follow-up and removal instructions. IFU, device description, indications, cont 1300 2008-07-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer