Autolith Touch

AUTOLITH TOUCH fragments biliary stones using electrohydraulic shock waves. A disposable bipolar probe passes through an endoscope, and the operator positions its tip near the stone under…

Registry build 21.09.26

AUTOLITH TOUCH fragments biliary stones using electrohydraulic shock waves. A disposable bipolar probe passes through an endoscope, and the operator positions its tip near the stone under direct endoscopic visualization.

A foot pedal activates high-voltage pulses at the probe tip in normal saline. The discharge creates short hydraulic shock waves that break the calculus into fragments for passage or removal.

Listed Item

Lithotripter, Biliary, BSC, Zero Cost Refurbished

Controls and Components

The tabletop unit connects to a foot switch, extender cable and compatible probes. Its interface selects power and pulse settings, detects the attached probe and displays delivered pulse information. The separate URO-TOUCH model is intended for renal stones.

1manufacturer
7catalogue numbers in this listing
11510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code FFK
Manufacturer City Province Registered as Device types
Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. Guangzhou Guangdong Manufacturer 4

Record

Regulatory record for Autolith Touch
Listed by Northgate Technologies Inc., United States
FDA product code FFK
Device type Lithotriptor, Electro-Hydraulic
Device class Class 2
Regulation 21 CFR 876.4480
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K130368
Record published 2017-03-10
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Autolith Touch
Catalogue number Size Status
M0054668R0 In distribution
M0054668H0 In distribution
M0054668D0 In distribution
M005466800 In distribution
M0054668ZR0 In distribution
M0054668L0 In distribution
9-202-00 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Lithoclast E.M.S. Electro Medical Systems S.A. 73
Calcusplit Karl Storz GmbH & Co. KG 22
Riwolith Richard Wolf Gmbh 14
Lithotriptor, Electro-Hydraulic Karl Storz GmbH & Co. KG 12
US-Litho Richard Wolf Gmbh 11
Gyrus Acmi Gyrus Acmi, Inc. 11
Lithotriptor, Electro-Hydraulic Richard Wolf Gmbh 9
EHL-Probe Walz Elektronik Gmbh 8
StoneBreaker Cook Incorporated 7
Swiss LithoClast Select E.M.S. Electro Medical Systems S.A. 5
Rigid Pneumatic Probe Boston Scientific Corporation 5
Ultrasound Probe Boston Scientific Corporation 4

Showing 12 of 73. All products under Lithotriptor, Electro-Hydraulic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K202813 2021-06-14
K130368 2013-11-15
K990341 1999-07-14
K944571 1995-03-17
K925396 1993-07-30
K923822 1993-01-28
K914517 1992-06-30
K914515 1992-01-07
K914516 1992-01-07
K914514 1992-01-06
K913955 1991-11-29

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Autolith Touch
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Northgate Technologies Inc. 510(k) number 2022-04-13 Class II Under Investigation by firm Product labeled incorrectly. 55 probes 2022-11-08
Northgate Technologies Inc. 510(k) number 2021-10-25 Class II Software design (manufacturing process) The languages for Russian, Romanian, Slovak, and Czech have the power settings for high and low switched in the device. 2,277 devices
Northgate Technologies Inc. 510(k) number 2020-03-10 Class II Nonconforming Material/Component As part of an investigation into a biocompatibility test discrepancy where a lot failed biocompatibility testing. 298 boxes. 3 units per box 2021-02-02
Northgate Technologies Inc. 510(k) number 2020-03-10 Class II Nonconforming Material/Component Investigation into a biocompatibility test discrepancy where a lot failed biocompatibility testing. 198 boxes. 3 units per box. 2021-02-02

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-03-10 Class II Nonconforming Material/Component Investigation into a biocompatibility test discrepancy where a lot failed biocompatibility testing. 1238 boxes. 3 units per box. 2021-02-02
2017-05-24 Class II Labeling mix-ups The inner and outer labels on the product contain incorrect reference number of 9-202-3751DS. According to Northgate Technologies, the resistor in the probe will not allow the mislabeled product to be used with the incorrect generator. Coul 186 2020-06-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer