Falcon

The Falcon rotatable retrieval basket is used to retrieve foreign bodies, tissue specimens, stones or calculi in endoscopic procedures of the gastrointestinal tract.

Registry build 21.09.26
2manufacturers in China registered for this device type
2catalogue numbers in this listing

Who Else Makes It

All of them in Shanghai.

Chinese manufacturers registered for FDA product code FGO
Manufacturer City Province Registered as Device types
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Innovex Medical Co., Ltd. Shanghai Shanghai Manufacturer 5

Record

Regulatory record for Falcon
Listed by Us Endoscopy, United States
FDA product code FGO
Device type Dislodger, Stone, Flexible
Device class Class 2
Regulation 21 CFR 876.4680
510(k) K962676
Record published 2020-03-19
Record revised 2021-04-07 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: Keep Dry
Packaging Case of 5, box of 5
Sizes Length 230 cm; width 35 mm; outer diameter 2.5 mm
Distribution end date 2022-11-28

Catalogue Numbers

Catalogue numbers for Falcon
Catalogue number Size Status
00711141 Length 230 cm Withdrawn
00711141 Width 35 mm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Gyrus Acmi Gyrus Acmi, Inc. 41
Dornier MedTech Dornier Medtech America, Inc. 13
Olympus Gyrus Acmi, Inc. 7
Dislodger, Stone, Flexible Stryker GmbH 5
Talon Us Endoscopy 2
USA Elite Gyrus Acmi, Inc. 2
Stone Cone Boston Scientific Corporation 2
Gyrus Icmi Gyrus Acmi, Inc. 1
Stone Retrieval Basket Applied Medical Resources Corp. 1
Soltive Gyrus Acmi, Inc. 1

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Falcon
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
United States Endoscopy Group, Inc. 510(k) number 2011-11-14 Class II Device Design When the outer catheter is either coiled or in a contorted configuration outside of the endoscope and the patient, and excessive force is applied to the handle, the jaws may become inoperable and may become stuck in the open condition. 1153 2013-07-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer