Disposable Triple Lumen Sphincterotome
14 catalogue numbers from KD-431Q-0720, listed by Olympus Medical Systems Corp., Japan, under Unit, Electrosurgical, Endoscopic (With Or Without Accessories). 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Zhejiang (3), Jiangsu (2), Beijing (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Beijing Zksk Technology Co., Ltd. | Beijing | Beijing | Contract manufacturer | 38 |
| Jiangsu Vedkang Medical Science and Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 20 |
| Hangzhou AGS MedTech Co., Ltd. | Hangzhou | Zhejiang | Repacker / relabeller | 19 |
| Anrei Medical (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 12 |
| Hebei Lufen Tech Co., Limited | Xingtai | Hebei | Contract manufacturer | 12 |
| Zhejiang Soudon Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 9 |
Record
| Listed by | Olympus Medical Systems Corp., Japan |
|---|---|
| FDA product code | KNS |
| Device type | Unit, Electrosurgical, Endoscopic (With Or Without Accessories) |
| Device class | Class 2 |
| Regulation | 21 CFR 876.4300 |
| Establishment | Specification developer, Manufacturer, Exporter |
| Record published | 2016-09-21 |
| Record revised | 2024-08-07 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2022-08-15 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| KD-431Q-0720 | In distribution | |
| KD-411Q-0320 | In distribution | |
| KD-411Q-0320 | In distribution | |
| KD-411Q-0730 | In distribution | |
| KD-411Q-0320 | In distribution | |
| KD-431Q-0720 | In distribution | |
| KD-431Q-0720 | In distribution | |
| KD-411Q-0320 | In distribution | |
| KD-401Q-0730 | Withdrawn | |
| KD-401Q-0330 | Withdrawn | |
| KD-431Q-0730 | Withdrawn | |
| KD-401Q-0720 | Withdrawn | |
| KD-401Q-0320 | Withdrawn | |
| KD-411Q-0320 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Guenter Bissinger Medizintechnik GmbH | Günter Bissinger Medizintechnik GmbH | 93 |
| Unit, Electrosurgical, Endoscopic (With Or Without Accessories) | Hangzhou AGS MedTech Co., Ltd. | 73 |
| Sphincterotome short-wire compatible | Micro-Tech (Nanjing) Co., Ltd. | 73 |
| Zksk | Beijing Zksk Technology Co., Ltd. | 72 |
| Single Use Preloaded Sphincterotome V(Distal Wireguided) | Olympus Medical Systems Corp. | 40 |
| Single Use Preloaded Sphincterotome V | Olympus Medical Systems Corp. | 40 |
| Sterile Sphincterotome | Micro-Tech (Nanjing) Co., Ltd. | 40 |
| Single Use 3-Lumen Sphincterotome V | Olympus Medical Systems Corp. | 37 |
| Single Use Electrosurgical Knife | Micro-Tech (Nanjing) Co., Ltd. | 21 |
| Single Use Sphincterotome V(Distal Wireguided) | Olympus Medical Systems Corp. | 20 |
| Cook | Cook Incorporated | 18 |
| Olympus | Olympus Winter & IBE Gmbh | 18 |
Showing 12 of 177. All products under Unit, Electrosurgical, Endoscopic (With Or Without Accessories)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252889 | 2025-11-25 |
| K250945 | 2025-10-17 |
| K250351 | 2025-10-10 |
| K193039 | 2019-12-17 |
| K182408 | 2019-05-15 |
| K171158 | 2017-11-17 |
| K160241 | 2016-03-02 |
| K150142 | 2015-10-08 |
| K122505 | 2013-04-11 |
| K092309 | 2009-10-30 |
Recalls Naming This Product
7 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Olympus Corporation of the Americas | UDI-DI | 2026-01-07 | Class II | Process control | Devices which did not undergo thermoforming could deform and lose performance. | 7689 units (7501 US, 188 OUS) |
| Olympus Corporation of the Americas | UDI-DI | 2026-01-07 | Class II | Process control | Devices which did not undergo thermoforming could deform and lose performance. | 887 units (650 US, 237 OUS) |
| Olympus Corporation of the Americas | UDI-DI | 2026-01-07 | Class II | Process control | Devices which did not undergo thermoforming could deform and lose performance. | 886 units (OUS only) |
| Olympus Corporation of the Americas | UDI-DI | 2026-01-07 | Class II | Process control | Devices which did not undergo thermoforming could deform and lose performance. | 1072 units (OUS only) |
| Olympus Corporation of the Americas | UDI-DI | 2026-01-07 | Class II | Process control | Devices which did not undergo thermoforming could deform and lose performance. | 1490 units (OUS only) |
| Olympus Corporation of the Americas | UDI-DI | 2026-01-07 | Class II | Process control | Devices which did not undergo thermoforming could deform and lose performance. | 999 units (OUS only) |
| Olympus Corporation of the Americas | UDI-DI | 2026-01-07 | Class II | Process control | Devices which did not undergo thermoforming could deform and lose performance. | 1980 units (OUS only) |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.