SpydrBlade Flex
SpydrBlade Flex is indicated for use in the cutting (incision, dissection, avulsion) of soft tissue using radiofrequency current and the coagulation (hemostasis, cauterization, ablation,…
SpydrBlade Flex is indicated for use in the cutting (incision, dissection, avulsion) of soft tissue using radiofrequency current and the coagulation (hemostasis, cauterization, ablation, arrest of bleeding) of soft tissue using microwave energy in the gastrointestinal tract as required or encountered in endoscopic procedures.
Who Else Makes It
Concentrated in Zhejiang (3), Jiangsu (2), Beijing (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Beijing Zksk Technology Co., Ltd. | Beijing | Beijing | Contract manufacturer | 38 |
| Jiangsu Vedkang Medical Science and Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 20 |
| Hangzhou AGS MedTech Co., Ltd. | Hangzhou | Zhejiang | Repacker / relabeller | 19 |
| Anrei Medical (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 12 |
| Hebei Lufen Tech Co., Limited | Xingtai | Hebei | Contract manufacturer | 12 |
| Zhejiang Soudon Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 9 |
Record
| Listed by | Creo Medical Ltd, United Kingdom |
|---|---|
| FDA product code | KNS |
| Device type | Unit, Electrosurgical, Endoscopic (With Or Without Accessories) |
| Device class | Class 2 |
| Regulation | 21 CFR 876.4300 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K242774 |
| Record published | 2025-06-12 |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Handling environment temperature 10 to 30 °C; Handling environment humidity 20 to 90 % RH; Handling environment atmospheric pressure 69 to 106 KiloPascal; Storage environment atmospheric pressure 69 to 109 KiloPascal; Storage environment humidity 20 to 90 % RH; Storage environment temperature 10 to 30 °C |
| Packaging | Shipper 5-up of 5 |
| Sizes | Length 1.8 m; outer diameter 2.7 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PRD-RG1-001 | Length 1.8 m | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Guenter Bissinger Medizintechnik GmbH | Günter Bissinger Medizintechnik GmbH | 93 |
| Unit, Electrosurgical, Endoscopic (With Or Without Accessories) | Hangzhou AGS MedTech Co., Ltd. | 73 |
| Sphincterotome short-wire compatible | Micro-Tech (Nanjing) Co., Ltd. | 73 |
| Zksk | Beijing Zksk Technology Co., Ltd. | 72 |
| Single Use Preloaded Sphincterotome V(Distal Wireguided) | Olympus Medical Systems Corp. | 40 |
| Single Use Preloaded Sphincterotome V | Olympus Medical Systems Corp. | 40 |
| Sterile Sphincterotome | Micro-Tech (Nanjing) Co., Ltd. | 40 |
| Single Use 3-Lumen Sphincterotome V | Olympus Medical Systems Corp. | 37 |
| Single Use Electrosurgical Knife | Micro-Tech (Nanjing) Co., Ltd. | 21 |
| Single Use Sphincterotome V(Distal Wireguided) | Olympus Medical Systems Corp. | 20 |
| Cook | Cook Incorporated | 18 |
| Olympus | Olympus Winter & IBE Gmbh | 18 |
Showing 12 of 177. All products under Unit, Electrosurgical, Endoscopic (With Or Without Accessories)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K242774 | 2025-06-06 |
| K242061 | 2024-08-15 |
| K230328 | 2023-10-31 |
| K192905 | 2020-03-19 |
| K171983 | 2017-08-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.