AquaBeam Scope

3 catalogue numbers from 210501, listed by Procept BioRobotics Corporation, United States, under Fluid Jet Removal System. 1 manufacturer in China is registered for this product code.

Registry build 21.09.26
1manufacturer
3catalogue numbers in this listing
9510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code PZP
Manufacturer City Province Registered as Device types
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8

Record

Regulatory record for AquaBeam Scope
Listed by Procept BioRobotics Corporation, United States
FDA product code PZP
Device type Fluid Jet Removal System
Device class Class 2
Regulation 21 CFR 876.4350
Establishment Specification developer, Manufacturer
510(k) DEN170024
Record published 2018-01-11
Record revised 2026-01-19 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Hydrogen Peroxide, Ethylene Oxide
Prescription Prescription only
Label carries lot or batch number, manufacturing date, serial number
Storage Storage environment temperature -18 to 60 °C

Catalogue Numbers

Catalogue numbers for AquaBeam Scope
Catalogue number Size Status
210501 In distribution
SC2000 In distribution
SC2000 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
AquaBeam Handpiece Procept BioRobotics Corporation 6
AquaBeam Robotic System Procept BioRobotics Corporation 3
Hydros Robotic System Procept BioRobotics Corporation 1
AquaBeam System Procept BioRobotics Corporation 1
Hydros Handpiece Procept BioRobotics Corporation 1

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260723 2026-07-09
K253211 2026-06-23
K251082 2025-10-10
K241952 2024-09-30
K240200 2024-08-20
K231024 2023-08-30
K212835 2021-10-06
K202961 2021-03-11
DEN170024 2017-12-21

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-07-09 Class II Component change control Scope tube tip may detach from the telescoping tube, which is attached to a single-use handpiece, a component of an aquablation robotic system. Both tip detachment and entire tip separation form the handpiece may lead to procedural delay fo 608
2019-03-06 Class II Process control Certain lots may develop an internal leak due to a micro-crack in a specific weld joint within the device. When the Robot detects this failure, it immediately renders the device inoperable and notifies the user via an error message, which m 214 2020-11-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker