Magic3 Go Male Catheter With SureGrip
Magic3 Go 12 Fr Male Catheter with SureGrip
Who Else Makes It
Concentrated in Jiangsu (9), Zhejiang (7), Shanghai (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Conod Medical Co., Limited | Changshu | Jiangsu | Contract manufacturer | 48 |
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Suzhou Jingle Polymer Medical Apparatus Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Haiyan Kangyuan Medical Instrument Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 17 |
| Jiangsu Suyun Medical Materials Co., Ltd. | Lianyungang | Jiangsu | Contract manufacturer | 11 |
| Integral Medical Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 7 |
| Shaoxing Fuqing Health Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 3 |
| Xianju Bever Medical Devices Co., Ltd. | Taizhou | Zhejiang | Contract manufacturer | 3 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
Showing 12 of 21. All 21 manufacturers in China registered for Catheter, Straight
Record
| Listed by | C.R. Bard, Inc., United States |
|---|---|
| FDA product code | EZD |
| Device type | Catheter, Straight |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5130 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2019-05-23 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 30, box of 360 |
| Sizes | Catheter gauge 10 to 20 Fr |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 53812G | Catheter Gauge 12 Fr | In distribution |
| 53814G | Catheter Gauge 14 Fr | In distribution |
| 53820G | Catheter Gauge 20 Fr | In distribution |
| 53818G | Catheter Gauge 18 Fr | In distribution |
| 53816G | Catheter Gauge 16 Fr | In distribution |
| 53810G | Catheter Gauge 10 Fr | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Disposable intermittent catheter (TPU Catheter) | Chengdu Daxan Innovative Medical Tech. Co., Ltd. | 140 |
| LoFric® Hydro-Kit™ | Wellspect Healthcare | 57 |
| LoFric® | Wellspect Healthcare | 56 |
| SimPro™ Now | Wellspect Healthcare | 55 |
| Self-Cath | Coloplast A/S | 50 |
| Wellead PVC Hydrophilic Urethral Catheter | Well Lead Medical Co., Ltd. | 50 |
| LoFric® Primo™ | Wellspect Healthcare | 48 |
| Medline | Medline Industries, Inc. | 47 |
| Halyard | Owens & Minor Distribution, Inc. | 39 |
| Cure Catheter | Convatec, Purchasing Department | 39 |
| AMSure® PVC Intermittent Catheter | Amsino Medical Inc. | 39 |
| LoFric® Origo™ | Wellspect Healthcare | 34 |
Showing 12 of 72. All products under Catheter, Straight
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K172247 | 2017-09-20 |
| K150345 | 2015-05-11 |
| K142575 | 2014-10-31 |
| K133470 | 2014-04-04 |
| K112137 | 2011-08-26 |
Recalls
7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2023-04-20 | Class II | Under Investigation by firm | Some catheters had a manufacturing defect where the clear resealing label separating from the product foil pouch, resulting in a possible opening into the product packaging that could impact product sterility. | 9894922 devices | |
| 2023-04-20 | Class II | Under Investigation by firm | Some catheters had a manufacturing defect where the clear resealing label separating from the product foil pouch, resulting in a possible opening into the product packaging that could impact product sterility. | 308520 devices | |
| 2023-04-20 | Class II | Under Investigation by firm | Some catheters had a manufacturing defect where the clear resealing label separating from the product foil pouch, resulting in a possible opening into the product packaging that could impact product sterility. | 5760 devices | |
| 2023-04-20 | Class II | Under Investigation by firm | Some catheters had a manufacturing defect where the clear resealing label separating from the product foil pouch, resulting in a possible opening into the product packaging that could impact product sterility. | 7427880 devices | |
| 2017-09-14 | Class II | Process control | Several instances of a catheter caught in the sterile barrier seal and in some instances cut catheters were observed. | 10,949,013 units in total | 2019-11-05 |
| 2017-09-14 | Class II | Process control | Several instances of a catheter caught in the sterile barrier seal and in some instances cut catheters were observed. | 44640.0 units | 2019-11-05 |
| 2017-09-14 | Class II | Process control | Several instances of a catheter caught in the sterile barrier seal and in some instances cut catheters were observed. | 10,949,013 units in total | 2019-11-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.