Accuryn SmartFoley IAP UO Temp Tray System 14fr
The Accuryn SmartFoley IAP UO Temp Tray System uses a 14 Fr urinary catheter to drain urine and support monitoring of urine output, core temperature and intra-abdominal pressure. Used with…
The Accuryn SmartFoley IAP UO Temp Tray System uses a 14 Fr urinary catheter to drain urine and support monitoring of urine output, core temperature and intra-abdominal pressure. Used with the Accuryn Monitor, its pressure readings aid assessment of intra-abdominal hypertension and abdominal compartment syndrome.
The silicone catheter has four lumens: urine drainage, retention-balloon inflation, a thermistor channel and a pressure-measurement channel. Urine flows through a preconnected collection set into a measurement cassette and then a collection bag. The monitor measures and displays output, temperature and pressure.
Listed Item
The Accuryn Monitoring System is intended for use in the drainage and/or collection of urine, and in the monitoring of urine output and core body temperature, in degrees Fahrenheit and degrees Celsius. The Accuryn Monitoring System with the Accuryn Sensing Urinary Catheter (SmartFoley) → IAP UO Temp is also intended for use in the monitoring of intra-abdominal pressure. The measured pressures can be used as an aid in the diagnosis of intra-abdominal hypertension (IAH) and the associated clinical syndrome of abdominal compartment syndrome (ACS). The Accuryn Sensing Urinary Catheter is a single use device intended for short term use (less than 30 days).
Use and Supply
The sterile catheter is disposable for a single use lasting less than 30 days. The system is intended for clinical personnel in hospitals, including operating and intensive care environments.
Who Else Makes It
Concentrated in Jiangsu (5), Zhejiang (4), Guangdong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Primecare Medical (Suzhou) Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 20 |
| Haiyan Kangyuan Medical Instrument Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 17 |
| Primecare Medical (Huzhou) Co., Ltd. | Hu Zhou | Zhejiang | Contract manufacturer | 9 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| Well Lead Medical (Hainan) Co., Ltd. | Haikou | Hainan | Contract manufacturer | 3 |
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Hangzhou Fushan Medical Appliance Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 44 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
| Hangzhou Primecare Medical Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Amsino Medical (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 22 |
Showing 12 of 17. All 17 manufacturers in China registered for Catheter, Retention Type, Balloon
Record
| Listed by | Potrero Medical, Inc., United States |
|---|---|
| FDA product code | EZL |
| Device type | Catheter, Retention Type, Balloon |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5130 |
| Establishment | Manufacturer |
| 510(k) | K221020 |
| Record published | 2023-03-30 |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Storage environment temperature 5 to 60 °C |
| Packaging | Case of 10 |
| Sizes | Catheter gauge 14 Fr |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| FGS-06-IAP.14FST | Catheter Gauge 14 Fr | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| All Silicone Foley Catheter | Well Lead Medical Co., Ltd. | 175 |
| Dover | Cardinal Health 200, LLC | 85 |
| Dover | Cardinal Health | 82 |
| Rusch | Teleflex Medical LLC | 79 |
| Porges Coloplast | Coloplast A/S | 74 |
| Medline | Medline Industries, Inc. | 72 |
| McKesson | Mckesson Medical-Surgical Inc. | 63 |
| TruCath | HR Pharmaceuticals Inc. | 59 |
| Folysil | Coloplast A/S | 47 |
| Sunmed | SunMed Group Holdings, LLC | 35 |
| Universa | Cook Incorporated | 31 |
| AMSure ® Hydrophilic Latex Foley Catheters | Amsino Medical Inc. | 31 |
Showing 12 of 135. All products under Catheter, Retention Type, Balloon
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K221020 | 2023-01-13 |
| K153655 | 2016-04-15 |