Salem Sump

Dual Lumen Stomach Tube Anti-Reflux Valve 10 Fr/Ch (3.3 mm) x 36 in (91 cm)

Registry build 21.09.26
3manufacturers in China registered for this device type
30catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Concentrated in Guangdong (1), Jiangsu (1), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code FEG
Manufacturer City Province Registered as Device types
Jiangsu Caina Medical Co., Ltd. Jiangyin Jiangsu Contract manufacturer 20
Well Lead Medical Co., Ltd. Guangzhou Guangdong Contract manufacturer 46
Ningbo Tianyi Medical Appliance Co., Ltd. Ningbo Zhejiang Contract manufacturer 11

Record

Regulatory record for Salem Sump
Listed by Cardinal Health 200, LLC, United States
FDA product code FEG
Device type Tube, Double Lumen For Intestinal Decompression And/Or Intubation
Device class Class 2
Regulation 21 CFR 876.5980
Establishment Contract manufacturer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Record published 2023-10-23
Record revised 2026-01-19 (version 10)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Packaging Case of 50, case of 10
Sizes Catheter gauge 8 to 18 Fr; length 61 to 122 cm; length 36 to 48 in
Distribution end date 2027-03-09

Catalogue Numbers

Catalogue numbers for Salem Sump
Catalogue number Size Status
8888266122 In distribution
7771010 In distribution
7771210 In distribution
8888264960E Length 122 cm In distribution
7771410 In distribution
8888264986E Length 122 cm In distribution
8888264929E Length 122 cm In distribution
8888266148 In distribution
8888266114 Catheter Gauge 12 Fr In distribution
8888264929E Catheter Gauge 12 Fr In distribution
266148 Catheter Gauge 18 Fr In distribution
7771810 In distribution
8888264911E Catheter Gauge 10 Fr In distribution
7771011 In distribution
8888268086E Length 61 cm In distribution
8888264945E Length 122 cm In distribution
266122 Catheter Gauge 14 Fr In distribution
266130 Catheter Gauge 16 Fr In distribution
7771811 In distribution
8888266106 Length 36 in In distribution
7771211 In distribution
8888266130 In distribution
8888264911E Length 91 cm In distribution
7771610 In distribution
7771411 In distribution
7771611 In distribution
266130 Catheter Gauge 16 Fr Withdrawn
8888266106 Catheter Gauge 10 Fr Withdrawn
266148 Catheter Gauge 18 Fr Withdrawn
266122 Catheter Gauge 14 Fr Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Salem Sump Cardinal Health 18
Bard® Nasogastric Sump Tube with PreVent® Anti-Reflux Filter C.R. Bard, Inc. 14
Axiom® Dual-Sump Axiom Medical, Inc. 9
Cardinal Health Cardinal Health 200, LLC 7
Axiom® Uni-Sump Axiom Medical, Inc. 7
Bard® Nasogastric Sump Tube and PreVent® Filter and Lopez Valve® with ENFit™ C.R. Bard, Inc. 6
Bilbao Dotter Cook Incorporated 4
Nasogastric Sump Tube with PreVent® Anti-Reflux Filter And Lopez Valve® C.R. Bard, Inc. 4
Kangaroo Cardinal Health 3
Marcon Cook Ireland Ltd 3
Axiom® Sump-n-Sheath® Axiom Medical, Inc. 3
Maglinte Cook Incorporated 2

Showing 12 of 24. All products under Tube, Double Lumen For Intestinal Decompression And/Or Intubation

Recalls Naming This Product

3 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Salem Sump
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Cardinal Health 200, LLC UDI-DI 2025-09-18 Class II Use error Firm has received complaints regarding Anti-Reflux Valve (ARV) breakage due to excessive force during use. Firm is providing additional guidance for use. Expansion of RES 95214. all lots
Cardinal Health 200, LLC UDI-DI 2025-09-18 Class II Use error Firm has received complaints regarding Anti-Reflux Valve (ARV) breakage due to excessive force during use. Firm is providing additional guidance for use. Expansion of RES 95214. all lots
Cardinal Health 200, LLC UDI-DI 2024-07-24 Class II Labeling Change Control The firm received reports of breakage in the Anti-Reflux Valve (ARV) due to improper use. As a result, changes to labeling were made. 24,761,100 tubes total

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-09-18 Class II Use error Firm has received complaints regarding Anti-Reflux Valve (ARV) breakage due to excessive force during use. Firm is providing additional guidance for use. Expansion of RES 95214. all lots

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker