AeroStat®
Indicated for use during open and laparoscopic cholecystectomy procedures to inject radiopaque media through the cystic duct into the biliary tree.
Who Else Makes It
Concentrated in Jiangsu (3), Zhejiang (2), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Zhejiang Chuangxiang Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Jiangsu Vedkang Medical Science and Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 20 |
| Hangzhou AGS MedTech Co., Ltd. | Hangzhou | Zhejiang | Repacker / relabeller | 19 |
| Dongguan TT Medical, Inc. | Dongguan | Guangdong | Manufacturer | 4 |
| LEO Medical Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 4 |
Record
| Listed by | Applied Medical Resources Corp., United States |
|---|---|
| FDA product code | FGE |
| Device type | Stents, Drains And Dilators For The Biliary Ducts |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5010 |
| Establishment | Contract manufacturer, Complaint-file establishment, Manufacturer |
| Record published | 2015-08-21 |
| Record revised | 2024-07-10 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Packaging | Pack of 5 |
| Sizes | Length 20 cm; catheter gauge 3 Fr |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| C1002 | Length 20 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Zimmon | Cook Ireland Ltd | 213 |
| Single Use Biliary Drainage Stent V | Olympus Medical Systems Corp. | 181 |
| Mustang™ | Boston Scientific Corporation | 167 |
| Geenen | Cook Ireland Ltd | 158 |
| Cotton-Leung | Cook Ireland Ltd | 144 |
| Advanix™ Pancreatic Stent | Boston Scientific Corporation | 135 |
| Single Use Biliary Stent V | Olympus Medical Systems Corp. | 106 |
| Single-use Balloon Dilatation Catheter | LEO Medical Co., Ltd. | 102 |
| Biliary Plastic Stent Set | Micro-Tech (Nanjing) Co., Ltd. | 90 |
| Biliary Plastic Stent | Micro-Tech (Nanjing) Co., Ltd. | 90 |
| M-Drain | Mermaid Medical A/S | 86 |
| Advanix™ Biliary | Boston Scientific Corporation | 84 |
Showing 12 of 212. All products under Stents, Drains And Dilators For The Biliary Ducts
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K983154 | 1999-05-05 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-08-09 | Class II | Material/Component Contamination | Applied Medical is recalling specific lot numbers of its Vascular Catheters because they may have a potential for packaging particulate matter to reside on the product. | 40,238 units for all products in Recall Event | 2013-03-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.