ReSolve®, StayFIX®
8 catalogue numbers from 00884450057520, listed by Merit Medical Systems, Inc., United States, under Stents, Drains And Dilators For The Biliary Ducts. 6 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Zhejiang (2), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Zhejiang Chuangxiang Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Jiangsu Vedkang Medical Science and Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 20 |
| Hangzhou AGS MedTech Co., Ltd. | Hangzhou | Zhejiang | Repacker / relabeller | 19 |
| Dongguan TT Medical, Inc. | Dongguan | Guangdong | Manufacturer | 4 |
| LEO Medical Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 4 |
Record
| Listed by | Merit Medical Systems, Inc., United States |
|---|---|
| FDA product code | FGE |
| Device type | Stents, Drains And Dilators For The Biliary Ducts |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5010 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2018-06-11 |
| Record revised | 2024-10-14 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Packaging | Pack of 5 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00884450057520 | French Size (F)-12F | In distribution |
| 00884450057841 | French Size (F)-8.5F | In distribution |
| 00884450057469 | Pigtail To Marker Band-14 cm | In distribution |
| 00884450071519 | Pigtail To Marker Band-14 cm | In distribution |
| 00884450057551 | Catheter Length (cm)-40 cm | In distribution |
| 00884450071502 | Catheter Length (cm)-40 cm | In distribution |
| 00884450057452 | French Size (F)-12F | In distribution |
| 00884450057490 | Pigtail To Marker Band-11 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Zimmon | Cook Ireland Ltd | 213 |
| Single Use Biliary Drainage Stent V | Olympus Medical Systems Corp. | 181 |
| Mustang™ | Boston Scientific Corporation | 167 |
| Geenen | Cook Ireland Ltd | 158 |
| Cotton-Leung | Cook Ireland Ltd | 144 |
| Advanix™ Pancreatic Stent | Boston Scientific Corporation | 135 |
| Single Use Biliary Stent V | Olympus Medical Systems Corp. | 106 |
| Single-use Balloon Dilatation Catheter | LEO Medical Co., Ltd. | 102 |
| Biliary Plastic Stent Set | Micro-Tech (Nanjing) Co., Ltd. | 90 |
| Biliary Plastic Stent | Micro-Tech (Nanjing) Co., Ltd. | 90 |
| M-Drain | Mermaid Medical A/S | 86 |
| Advanix™ Biliary | Boston Scientific Corporation | 84 |
Showing 12 of 212. All products under Stents, Drains And Dilators For The Biliary Ducts
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K151925 | 2015-11-06 |
| K141408 | 2014-11-26 |
| K121832 | 2012-07-17 |
| K093947 | 2010-01-21 |
| K063733 | 2007-11-14 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-01-16 | Class II | Nonconforming Material/Component | A consumer complaint that a catheter was observed to be in several pieces under patient fluoroscopic visualization. | 387 units | 2015-09-16 |
| 2010-01-28 | Not classified | Component change control | Degradation of the outer portion of the delivery catheter may prevent proper deployment of the biliary stent. | 69 units | 2010-04-27 |
| 2010-01-28 | Not classified | Component change control | Degradation of the outer portion of the delivery catheter may prevent proper deployment of the biliary stent. | 16 units | 2010-04-27 |
| 2010-01-28 | Not classified | Component change control | Degradation of the outer portion of the delivery catheter may prevent proper deployment of the biliary stent. | 8 units | 2010-04-27 |
| 2010-01-28 | Not classified | Component change control | Degradation of the outer portion of the delivery catheter may prevent proper deployment of the biliary stent. | 15 units | 2010-04-27 |
| 2010-01-28 | Not classified | Component change control | Degradation of the outer portion of the delivery catheter may prevent proper deployment of the biliary stent. | 51 units | 2010-04-27 |
| 2010-01-28 | Not classified | Component change control | Degradation of the outer portion of the delivery catheter may prevent proper deployment of the biliary stent. | 6 units | 2010-04-27 |
| 2008-11-07 | Not classified | Other | Biliary drainage catheter tips may separate from the catheter shaft after placement. | 108 units | 2009-08-05 |
| 2008-11-07 | Not classified | Other | Biliary drainage catheter tips may separate from the catheter shaft after placement. | 284 units | 2009-08-05 |
| 2008-11-07 | Not classified | Other | Biliary drainage catheter tips may separate from the catheter shaft after placement. | 528 units | 2009-08-05 |
| 2008-11-07 | Not classified | Other | Biliary drainage catheter tips may separate from the catheter shaft after placement. | 244 units | 2009-08-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.