Syntel® Cholangiography Catheters
Indicated for the injection of contrast solution into the common duct.
Who Else Makes It
Concentrated in Jiangsu (3), Zhejiang (2), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Zhejiang Chuangxiang Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Jiangsu Vedkang Medical Science and Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 20 |
| Hangzhou AGS MedTech Co., Ltd. | Hangzhou | Zhejiang | Repacker / relabeller | 19 |
| Dongguan TT Medical, Inc. | Dongguan | Guangdong | Manufacturer | 4 |
| LEO Medical Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 4 |
Record
| Listed by | Applied Medical Resources Corp., United States |
|---|---|
| FDA product code | FGE |
| Device type | Stents, Drains And Dilators For The Biliary Ducts |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5010 |
| Establishment | Contract manufacturer, Complaint-file establishment, Manufacturer |
| Record published | 2015-08-21 |
| Record revised | 2018-11-12 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Sizes | Length 40 cm; catheter gauge 4 to 6 Fr |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CHO-040-4F | Length 40 cm | In distribution |
| CHO-040-6F | Length 40 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Zimmon | Cook Ireland Ltd | 213 |
| Single Use Biliary Drainage Stent V | Olympus Medical Systems Corp. | 181 |
| Mustang™ | Boston Scientific Corporation | 167 |
| Geenen | Cook Ireland Ltd | 158 |
| Cotton-Leung | Cook Ireland Ltd | 144 |
| Advanix™ Pancreatic Stent | Boston Scientific Corporation | 135 |
| Single Use Biliary Stent V | Olympus Medical Systems Corp. | 106 |
| Single-use Balloon Dilatation Catheter | LEO Medical Co., Ltd. | 102 |
| Biliary Plastic Stent Set | Micro-Tech (Nanjing) Co., Ltd. | 90 |
| Biliary Plastic Stent | Micro-Tech (Nanjing) Co., Ltd. | 90 |
| M-Drain | Mermaid Medical A/S | 86 |
| Advanix™ Biliary | Boston Scientific Corporation | 84 |
Showing 12 of 212. All products under Stents, Drains And Dilators For The Biliary Ducts
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K983154 | 1999-05-05 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-08-09 | Class II | Material/Component Contamination | Applied Medical is recalling specific lot numbers of its Vascular Catheters because they may have a potential for packaging particulate matter to reside on the product. | 40,238 units for all products in Recall Event | 2013-03-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.