Cartridge Blood Set

The Gambro Cartridge Blood Set is intended for single use in a hemodialysis treatment using the Phoenix Dialysis Delivery System from Rev. SW 3.40. The Low Weight - Low Volume model is used…

Registry build 21.09.26

The Gambro Cartridge Blood Set is intended for single use in a hemodialysis treatment using the Phoenix Dialysis Delivery System from Rev. SW 3.40. The Low Weight – Low Volume model is used when a low extracorporeal blood volume is recommended.

5manufacturers in China registered for this device type
8catalogue numbers in this listing

Who Else Makes It

Concentrated in Guangdong (3), Zhejiang (1), Jiangxi (1).

Chinese manufacturers registered for FDA product code FJK
Manufacturer City Province Registered as Device types
Ningbo Tianyi Medical Appliance Co., Ltd. Ningbo Zhejiang Contract manufacturer 11
Guangzhou Kaiheng K&S Co., Ltd. Guangzhou Guangdong Contract manufacturer 9
Jiangxi Sanxin Medtec Co., Ltd. Nanchang Jiangxi Manufacturer 6
Bain Medical Equipment(Guangzhou) Co., Ltd. Guangzhou Guangdong Manufacturer 3
Vital Healthcare (Guangzhou) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3

Record

Regulatory record for Cartridge Blood Set
Listed by Gambro Renal Products S.A. DE C.V., Mexico
FDA product code FJK
Device type Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
Device class Class 2
Regulation 21 CFR 876.5820
Establishment Manufacturer
Record published 2015-10-23
Record revised 2025-07-21 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment temperature -18 to 49 °C; Storage environment temperature 0 to 120 °F; Special storage condition: The blood transport system must be stored in a dry place
Packaging Case of 15, case of 5, case of 10

Catalogue Numbers

Catalogue numbers for Cartridge Blood Set
Catalogue number Size Status
103402 In distribution
101025 In distribution
101290 In distribution
114434 In distribution
114435 In distribution
103401 In distribution
106289 In distribution
109536 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ICU Medical ICU Medical, Inc 58
Nipro SET Blood Tubing SET With Transducer Protectors AND Priming SET Nipro Medical Corporation 12
Hemodialysis Bloodlines B. Braun Medical Inc. 12
CombiSet Fresenius Medical Care 11
5008X Fresenius Medical Care Renal Therapies Group, LLC 7
Sunder Sunder Biomedical Tech. Co., Ltd. 6
Streamline Airless System Set with Locksite Needleless Access Sites Medisystems Corp. 5
Tablo(R) Cartridge Outset Medical, Inc. 5
NovaLine Bain Medical Equipment(Guangzhou) Co., Ltd. 5
Medisystems Hemodialysis Blood Tubing Sets Medisystems Corp. 4
Diapact® B. Braun Medical Inc. 4
Vital Vital Healthcare SDN. BHD. 3

Showing 12 of 44. All products under Set, Tubing, Blood, With And Without Anti-Regurgitation Valve

Recalls Naming This Product

10 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Cartridge Blood Set
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Baxter Healthcare Corporation UDI-DI 2021-04-14 Class II Under Investigation by firm There is a potential leak between the venous patient connector and patient’s hemodialysis access. 17,487 units 2024-05-10
Baxter Healthcare Corporation UDI-DI 2020-12-30 Class II Under Investigation by firm complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. 7437480 units
Baxter Healthcare Corporation UDI-DI 2020-12-30 Class II Under Investigation by firm complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. 385 devices
Baxter Healthcare Corporation UDI-DI 2020-12-30 Class II Under Investigation by firm complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. 1460 devices
Baxter Healthcare Corporation UDI-DI 2020-12-30 Class II Under Investigation by firm complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. 211155 devices
Baxter Healthcare Corporation UDI-DI 2020-12-30 Class II Under Investigation by firm complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. 57825 devices
Baxter Healthcare Corporation UDI-DI 2020-12-30 Class II Under Investigation by firm complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. 25785 devices
Baxter Healthcare Corporation UDI-DI 2020-04-17 Class II Process control Potential disconnection of tubing set. 2,361,885 units 2023-02-07
Baxter Healthcare Corporation UDI-DI 2020-04-17 Class II Process control Potential disconnection of tubing set. 53,895 units 2023-02-07
Baxter Healthcare Corporation UDI-DI 2020-04-17 Class II Process control Potential disconnection of tubing set. 4,065 2023-02-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer