Who Else Makes It

Concentrated in Jiangsu (8), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KNQ
Manufacturer City Province Registered as Device types
Changzhou Health Microport Medical Device Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Changzhou Jiuhong Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Jiangsu Changmei Medtech Co., Ltd. Changzhou Jiangsu Contract manufacturer 8
Micro-Tech (Nanjing) Co., Ltd. Nan Jing Jiangsu Contract manufacturer 49
Jiangsu Vedkang Medical Science and Technology Co., Ltd. Changzhou Jiangsu Manufacturer 20
Hangzhou AGS MedTech Co., Ltd. Hangzhou Zhejiang Repacker / relabeller 19
Jiangsu Grit Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 13
Jiangsu Power-Endo Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 7
LEO Medical Co., Ltd. Changzhou Jiangsu Manufacturer 4

Record

Regulatory record for SafeGuide®
Listed by Diversatek Healthcare Inc, United States
FDA product code KNQ
Device type Dilator, Esophageal
Device class Class 2
Regulation 21 CFR 876.5365
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Record published 2016-09-17
Record revised 2022-06-10 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization, High-level Disinfectant
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date
Packaging Case of 3, case of 2, case of 6
Sizes Catheter gauge 15 to 60 Fr; length 86 to 210 cm

Catalogue Numbers

Catalogue numbers for SafeGuide®
Catalogue number Size Per pack Status
1214-02 Length 210 cm In distribution
1214-02S Length 210 cm In distribution
1214-60 Catheter Gauge 60 Fr In distribution
1214-04 Length 210 cm 25 In distribution
1214-03RS Length 86 cm In distribution
1214-15 Catheter Gauge 15 Fr In distribution
1214-39 Catheter Gauge 39 Fr In distribution
1214-57 Catheter Gauge 57 Fr In distribution
1214-10 In distribution
1214-03D Length 86 cm In distribution
1214-03R Length 86 cm In distribution
1214-54 Catheter Gauge 54 Fr In distribution
1214-33 Catheter Gauge 33 Fr In distribution
1214-51 Catheter Gauge 51 Fr In distribution
1214-18 Catheter Gauge 18 Fr In distribution
1214-36 Catheter Gauge 36 Fr In distribution
1214-00 In distribution
1214-24 Catheter Gauge 24 Fr In distribution
1214-27 Catheter Gauge 27 Fr In distribution
1214-45 Catheter Gauge 45 Fr In distribution
1214-48 Catheter Gauge 48 Fr In distribution
1214-30 Catheter Gauge 30 Fr In distribution
1214-02D Length 210 cm In distribution
1214-42 Catheter Gauge 42 Fr In distribution
1214-21 Catheter Gauge 21 Fr In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Disposable Dilation Balloon Micro-Tech (Nanjing) Co., Ltd. 99
Reliant(TM) Multistage Dilatation Balloon Catheter Micro-Tech (Nanjing) Co., Ltd. 37
Quantum TTC Cook Incorporated 27
Savary Gilliard Cook Incorporated 26
Eliminator ConMed Corporation 21
ABC Dilatation Balloon Catheter Micro-Tech (Nanjing) Co., Ltd. 21
Flex-Ez Over the Wire Balloon Dilator Hobbs Medical, Inc. 19
Flex-Ez Stylet Wire Balloon Dilator Hobbs Medical, Inc. 19
Elation 5™ Merit Medical Systems, Inc. 18
SafeGuide® Single Diversatek Healthcare Inc 16
Conmed CleanGuide Jiangsu Grit Medical Technology Co., Ltd. 16
Conmed ConMed Corporation 16

Showing 12 of 40. All products under Dilator, Esophageal

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-03-18 Class II Labeling Change Control The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage. 15 units
2026-03-18 Class II Labeling Change Control The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage. 527 units
2026-03-18 Class II Labeling Change Control The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage. 1383 units
2026-03-18 Class II Labeling Change Control The catheter inflation tag attached to the device may contain an incorrect part number with incorrect balloon diameter sizes and inflation pressures for each stage. 250 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer