ENFit Extension Set

30” ENFit Extension Set Standard Orange

Registry build 21.09.26
25manufacturers in China registered for this device type
27catalogue numbers in this listing
4510(k) clearances naming this product code
35recalls on this code

Who Else Makes It

Concentrated in Jiangsu (17), Zhejiang (4), Guangdong (2). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KNT
Manufacturer City Province Registered as Device types
Amsino Medical (Kunshan) Co., Ltd. Kunshan Jiangsu Contract manufacturer 53
Jiangsu JianYu Health Medical Co., Ltd. Changzhou Jiangsu Contract manufacturer 35
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22
Jiangsu Caina Medical Co., Ltd. Jiangyin Jiangsu Contract manufacturer 20
Jiangsu Weikang Jiejing Medical Apparatus Co., Ltd. Shuyang Jiangsu Contract manufacturer 18
Mcreat ( Guangzhou ) BIO-Tech Co., Ltd. Guangzhou Guangdong Contract manufacturer 14
Primecare Medical (Huzhou) Co., Ltd. Hu Zhou Zhejiang Contract manufacturer 9
Yangzhou Xingwei Medical Technology Co., Ltd. Yangzhou Jiangsu Contract manufacturer 5
Tessy Plastics Shanghai Co., Ltd. Shanghai Shanghai Contract manufacturer 4
Flexan (Suzhou) Precision Rubber Products Co., Ltd. Suzhou Jiangsu Contract manufacturer 1
Huzhou Junda Industry Co., Ltd. Anji Zhejiang Contract manufacturer 129

Showing 12 of 25. All 25 manufacturers in China registered for Tubes, Gastrointestinal (And Accessories)

Record

Regulatory record for ENFit Extension Set
Listed by Avanos Medical, Inc., United States
FDA product code KNT
Device type Tubes, Gastrointestinal (And Accessories)
Device class Class 2
Regulation 21 CFR 876.5980
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K100288
Record published 2021-04-23
Record revised 2023-06-22 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Packaging Case of 8

Catalogue Numbers

Catalogue numbers for ENFit Extension Set
Catalogue number Size Status
NM-40ENENB In distribution
PNM-18ENENB In distribution
PEXT-8YNC In distribution
NM-48ENENB In distribution
PNM-48ENENB In distribution
PEXT-40BNC In distribution
PEXT-30NC In distribution
EXT-18BNC In distribution
NM-30ENEN In distribution
PEXT-60NC In distribution
EXT-30NC In distribution
PNM-40ENENB In distribution
NM-60ENEN In distribution
NM-60ENENY In distribution
PNM-60ENENY In distribution
EXT-48BNC In distribution
PEXT-60YNC In distribution
PEXT-30BNC In distribution
EXT-30BNC In distribution
EXT-60YNC In distribution
EXT-60NC In distribution
EXT-8YNC In distribution
PEXT-18BNC In distribution
EXT-40BNC In distribution
PNM-60ENEN In distribution
NM-18ENENB In distribution
PEXT-48BNC In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Avanos Avanos Medical, Inc. 1,169
Halyard Avanos Medical, Inc. 1,004
G-Jet® Transgastric-Jejunal Feeding Device Applied Medical Technology, Inc. 376
MiniONE Balloon Button Applied Medical Technology, Inc. 373
Mini ONE® Balloon Button Applied Medical Technology, Inc. 336
Kangaroo Cardinal Health 326
NutraGlide Nasal Feeding Tube Applied Medical Technology, Inc. 279
AMT Mini™ Balloon Button Applied Medical Technology, Inc. 231
Vygon Vygon Corp. 229
NeoDevices, Inc. Neodevices Inc 123
Corflo cuBBy Lpgd Corpak Medsystems 98
Kangaroo Cardinal Health 200, LLC 98

Showing 12 of 457. All products under Tubes, Gastrointestinal (And Accessories)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241185 2024-10-25
K240965 2024-06-06
K220588 2022-04-22
K191340 2019-06-04

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of ENFit Extension Set
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Avanos Medical, Inc. 510(k) number 2018-10-24 Class III Under Investigation by firm The sterile pouch label states the expiration date is 2016-11-19, but the correct expiration date is 2019-11-09. The case label and the shipper label have the correct date 654 boxes (32700 units) 2020-09-16

Recalls

3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 234 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 54 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 208 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 31 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 218 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 61 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 22 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 1,615 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 901 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 72 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 1,205 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 53 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 1,006 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 3,184 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 231 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 49 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 6,005 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 41 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 43 kits
2026-04-30 Class II Material/Component Contamination Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. 132 kits
2024-05-31 Class II Error in labeling The IFU was missing some risk information requested by another country to be contained in the IFU pertaining to potential complications. 53,384 kits
2024-01-16 Class I Nonconforming Material/Component MIC* Gastric – Jejunal Feeding Tube Kits contain a sterile pre-filled syringe subsequently recalled by Nurse Assist. 10808 units
2024-01-16 Class I Nonconforming Material/Component MIC* Gastric – Jejunal Feeding Tube Kits contain a sterile pre-filled syringe subsequently recalled by Nurse Assist. 53126 Units
2022-03-21 Class I Device Design Product labeling is being modified. STOP using the Anonymous Account Mode feature of the CORTRAK 2 device immediately. CONFIRM placement of the NG/NI tube per institution protocol. 721 devices 2024-09-09
2021-12-22 Class II Under Investigation by firm The External Retention Bolster contained in the kit may be a larger diameter than the tube. 692 units 2023-08-15
2021-12-22 Class II Under Investigation by firm The External Retention Bolster contained in the kit may be a larger diameter than the tube. 2652 units 2023-08-15
2020-10-16 Class II Under Investigation by firm Detachment of the Male AIV Adaptor from the Y-Connector. 710 units 2022-09-30
2020-07-29 Class II Under Investigation by firm Devices had cracked or detached from the feeding tube body 284 units 2023-01-31
2019-10-08 Class II Under Investigation by firm The connector piece to the PEG tube does not pass over the guidewire. 104 cases (208 units) total 2022-03-16
2019-10-08 Class II Under Investigation by firm The connector piece to the PEG tube does not pass over the guidewire. 104 cases (208 units) total 2022-03-16
2017-02-03 Class II Device Design Firm is initiating voluntary correction of CORFLO PEG with ENFit. Barb connector (stem) of the adapter may break unexpectedly when exposed to stress. 2 cases (5 units per case) 2019-08-05
2017-02-03 Class II Device Design Firm is initiating voluntary correction of CORFLO PEG with ENFit. Barb connector (stem) of the adapter may break unexpectedly when exposed to stress. 8 cases (2 units per case) 2019-08-05
2017-02-03 Class II Device Design Firm is initiating voluntary correction of CORFLO PEG with ENFit. Barb connector (stem) of the adapter may break unexpectedly when exposed to stress. 2 cases (5 units per case) 2019-08-05
2012-01-26 Not classified Mixed-up of materials/components The wrong size Twoomey adapter was packaged with the Jejunal tube. 145 units 2012-03-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer