Salem Sump

Silicone Dual Lumen Stomach Tube,Anti-Reflux Valve and Radiopaque Line

Registry build 21.09.26
25manufacturers in China registered for this device type
19catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (17), Zhejiang (4), Guangdong (2). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KNT
Manufacturer City Province Registered as Device types
Amsino Medical (Kunshan) Co., Ltd. Kunshan Jiangsu Contract manufacturer 53
Jiangsu JianYu Health Medical Co., Ltd. Changzhou Jiangsu Contract manufacturer 35
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22
Jiangsu Caina Medical Co., Ltd. Jiangyin Jiangsu Contract manufacturer 20
Jiangsu Weikang Jiejing Medical Apparatus Co., Ltd. Shuyang Jiangsu Contract manufacturer 18
Mcreat ( Guangzhou ) BIO-Tech Co., Ltd. Guangzhou Guangdong Contract manufacturer 14
Primecare Medical (Huzhou) Co., Ltd. Hu Zhou Zhejiang Contract manufacturer 9
Yangzhou Xingwei Medical Technology Co., Ltd. Yangzhou Jiangsu Contract manufacturer 5
Tessy Plastics Shanghai Co., Ltd. Shanghai Shanghai Contract manufacturer 4
Flexan (Suzhou) Precision Rubber Products Co., Ltd. Suzhou Jiangsu Contract manufacturer 1
Huzhou Junda Industry Co., Ltd. Anji Zhejiang Contract manufacturer 129

Showing 12 of 25. All 25 manufacturers in China registered for Tubes, Gastrointestinal (And Accessories)

Record

Regulatory record for Salem Sump
Listed by Cardinal Health, United States
FDA product code KNT
Device type Tubes, Gastrointestinal (And Accessories)
Device class Class 2
Regulation 21 CFR 876.5980
Establishment Contract manufacturer, Reprocessor, Contract steriliser, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K830710
Record published 2016-09-24
Record revised 2025-12-31 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Special storage condition: Keep dry;AVOID DIRECT SUNLIGHT
Packaging Case of 10, case of 50
Sizes Length 24 to 48 in; catheter gauge 6 to 18 Fr; outer diameter 16 in
Distribution end date 2025-12-31

Catalogue Numbers

Catalogue numbers for Salem Sump
Catalogue number Size Status
8888265132 In distribution
8888266247 Length 48 in In distribution
8888266288 Catheter Gauge 18 Fr In distribution
8888265140 In distribution
8888265108 In distribution
8888266213 Catheter Gauge 10 Fr In distribution
8888266262 Length 48 in In distribution
8888265116 In distribution
8888265124 In distribution
8888266221 Length 48 in In distribution
8888268060 Catheter Gauge 6 Fr Withdrawn
8888264986 Length 48 in Withdrawn
264960 Catheter Gauge 16 Fr Withdrawn
8888264911 Catheter Gauge 10 Fr Withdrawn
8888268086 Length 24 in Withdrawn
8888264945 Catheter Gauge 14 Fr Withdrawn
8888266197 Withdrawn
8888264960 Length 48 in Withdrawn
8888264929 Catheter Gauge 12 Fr Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Avanos Avanos Medical, Inc. 1,169
Halyard Avanos Medical, Inc. 1,004
G-Jet® Transgastric-Jejunal Feeding Device Applied Medical Technology, Inc. 376
MiniONE Balloon Button Applied Medical Technology, Inc. 373
Mini ONE® Balloon Button Applied Medical Technology, Inc. 336
Kangaroo Cardinal Health 326
NutraGlide Nasal Feeding Tube Applied Medical Technology, Inc. 279
AMT Mini™ Balloon Button Applied Medical Technology, Inc. 231
Vygon Vygon Corp. 229
NeoDevices, Inc. Neodevices Inc 123
Corflo cuBBy Lpgd Corpak Medsystems 98
Kangaroo Cardinal Health 200, LLC 98

Showing 12 of 457. All products under Tubes, Gastrointestinal (And Accessories)

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Salem Sump
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Cardinal Health 200, LLC 510(k) number 2025-09-18 Class II Use error Firm has received complaints regarding Anti-Reflux Valve (ARV) breakage due to excessive force during use. Firm is providing additional guidance for use. Expansion of RES 95214. all lots

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer